Crocus SHDSL Repeater 2P - Route 66 Communications
Crocus SHDSL Repeater 2P - Route 66 Communications Crocus SHDSL Repeater 2P - Route 66 Communications
14 Crocus SHDSL Repeater 2P Chapter 2 User manual Installing and connecting the Crocus SHDSL Repeater 2P Part label DP / LP Function This is the power selection switch. The Crocus SHDSL Repeater 2P can either be powered locally or remotely by the LTU. Use the power selection switch to select between local and dual powering. Switch setting LP (local power) DP (dual power) Function The Crocus SHDSL Repeater 2P is powered by a local power supply only. The Crocus SHDSL Repeater 2P is powered remotely by the LTU. However, you can also connect a local power supply. In that case, if the remote power fails, then the local power takes over. In order to change the switch setting, use a thin plastic tool. Never use a metal object! -48 VDC This is the power connector. If you want to power the Crocus SHDSL Repeater 2P using a local power supply, then connect the -48 Vdc to this connector. Do this by wiring the mini-fit plug delivered with the Crocus SHDSL Repeater 2P and plug it in the mini-fit power connector. Refer to 5.8 - Power connector lay-out on page 54 for more information on this connector. NE / FE xDSL These are the Near End (NE) and Far End (FE) SHDSL line connectors. Connect the … • NE connector to the SHDSL line going to the near end, also called network side or N-side. • FE connector to the SHDSL line going to the far end, also called customer side or C-side. For optimum performance, the line pairs have to be twisted properly. Refer to … • 5.2 - Line connector lay-out on page 48 for more information on this connector. • 3.1 - Connecting the NE side and FE side on page 30 for more information on connecting the SHDSL line connector.
Crocus SHDSL Repeater 2P Chapter 2 15 User manual Installing and connecting the Crocus SHDSL Repeater 2P 2.6 Mounting and connecting the outdoor Crocus SHDSL Repeater 2P This section shows you how to mount and connect the outdoor Crocus SHDSL Repeater 2P. The following gives an overview of this section: • 2.6.1 - Parts of the outdoor Crocus SHDSL Repeater 2P on page 16 • 2.6.2 - Mounting the outdoor Crocus SHDSL Repeater 2P on page 17 • 2.6.3 - Adding a security seal on page 18 • 2.6.4 - Connecting the IP67 signal connector on page 19 • 2.6.5 - Connecting the IP67 power connector on page 21 • 2.6.6 - Changing the LP/DP switch setting on page 23 • 2.6.7 - Replacing the Crocus SHDSL Repeater 2P motherboard on page 24
- Page 1 and 2: Crocus SHDSL Repeater 2P Crocus SHD
- Page 3 and 4: Crocus SHDSL Repeater 2P User manua
- Page 5 and 6: Crocus SHDSL Repeater 2P User manua
- Page 7 and 8: Crocus SHDSL Repeater 2P User manua
- Page 9 and 10: Crocus SHDSL Repeater 2P 1 User man
- Page 11 and 12: Crocus SHDSL Repeater 2P Chapter 1
- Page 13 and 14: Crocus SHDSL Repeater 2P Chapter 1
- Page 15 and 16: Crocus SHDSL Repeater 2P Chapter 1
- Page 17 and 18: Crocus SHDSL Repeater 2P Chapter 2
- Page 19 and 20: Crocus SHDSL Repeater 2P Chapter 2
- Page 21: Crocus SHDSL Repeater 2P Chapter 2
- Page 25 and 26: Crocus SHDSL Repeater 2P Chapter 2
- Page 27 and 28: Crocus SHDSL Repeater 2P Chapter 2
- Page 29 and 30: Crocus SHDSL Repeater 2P Chapter 2
- Page 31 and 32: Crocus SHDSL Repeater 2P Chapter 2
- Page 33 and 34: Crocus SHDSL Repeater 2P Chapter 2
- Page 35 and 36: Crocus SHDSL Repeater 2P Chapter 2
- Page 37 and 38: Crocus SHDSL Repeater 2P Chapter 3
- Page 39 and 40: Crocus SHDSL Repeater 2P Chapter 3
- Page 41 and 42: Crocus SHDSL Repeater 2P Chapter 3
- Page 43 and 44: Crocus SHDSL Repeater 2P Chapter 3
- Page 45 and 46: Crocus SHDSL Repeater 2P Chapter 4
- Page 47 and 48: Crocus SHDSL Repeater 2P Chapter 4
- Page 49 and 50: Crocus SHDSL Repeater 2P Chapter 4
- Page 51 and 52: Crocus SHDSL Repeater 2P Chapter 4
- Page 53 and 54: Crocus SHDSL Repeater 2P Chapter 4
- Page 55 and 56: Crocus SHDSL Repeater 2P Chapter 5
- Page 57 and 58: Crocus SHDSL Repeater 2P Chapter 5
- Page 59 and 60: Crocus SHDSL Repeater 2P Chapter 5
- Page 61 and 62: Crocus SHDSL Repeater 2P Chapter 5
- Page 63 and 64: Crocus SHDSL Repeater 2P Chapter 5
- Page 65 and 66: Crocus SHDSL Repeater 2P 57 Annex A
- Page 67 and 68: Crocus SHDSL Repeater 2P Annex A: 5
- Page 69 and 70: Crocus SHDSL Repeater 2P Annex Inde
<strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> Chapter 2 15<br />
User manual<br />
Installing and connecting the <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong><br />
2.6 Mounting and connecting the outdoor <strong>Crocus</strong> <strong>SHDSL</strong><br />
<strong>Repeater</strong> <strong>2P</strong><br />
This section shows you how to mount and connect the outdoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong>. The following<br />
gives an overview of this section:<br />
• 2.6.1 - Parts of the outdoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> on page 16<br />
• 2.6.2 - Mounting the outdoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> on page 17<br />
• 2.6.3 - Adding a security seal on page 18<br />
• 2.6.4 - Connecting the IP67 signal connector on page 19<br />
• 2.6.5 - Connecting the IP67 power connector on page 21<br />
• 2.6.6 - Changing the LP/DP switch setting on page 23<br />
• 2.6.7 - Replacing the <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> motherboard on page 24