Crocus SHDSL Repeater 2P - Route 66 Communications
Crocus SHDSL Repeater 2P - Route 66 Communications
Crocus SHDSL Repeater 2P - Route 66 Communications
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
12 <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> Chapter 2<br />
User manual<br />
Installing and connecting the <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong><br />
2.3 Selecting a site<br />
Indoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong><br />
Indoor use only! Install the unit in an area free of extreme temperatures, humidity, shock and vibration.<br />
Position it so that you can easily see and access the front panel. Leave enough clearance at the back<br />
for cables and wires. Position the unit within the correct distances for the different accesses and, if powered<br />
locally, within 2m of a power outlet.<br />
Outdoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong><br />
Outdoor use is allowed. Protection against moisture, vibration and impact.<br />
2.4 Connection precautions<br />
ESD warning<br />
The circuit boards are sensitive to electrostatic discharges (ESD) and should be handled with care. It is<br />
advisable to ensure an optimal electrical contact between yourself, the working area and a safety ground<br />
before touching any circuit board. Take special care not to touch any component or connector on the<br />
circuit board.<br />
EMC compliant installation<br />
The Telindus access products are fully EMC compliant. To ensure compliance with EMC directive 89/<br />
336/EEC, shielded cables or ferrite beads have to be used.<br />
The connectors of the <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> should only be connected to the following circuit<br />
types:<br />
Connector name Connector label Connector type Circuit type<br />
monitor connector MONITOR subD-9 SELV<br />
<strong>SHDSL</strong> line connector xDSL RJ45 TNV-1 1 /<br />
TNV-3 2<br />
1. without remote powering<br />
2. with remote powering<br />
• SELV (Safety Extra Low Voltage): local connection (e.g. PC to <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong>) or<br />
leased line inside the building.<br />
• TNV-1 (Telecom Network Voltage): leased line outside the building.<br />
• TNV-2: PSTN from PABX inside the building.<br />
• TNV-3: PSTN from operator PABX outside the building.