06.04.2014 Views

Crocus SHDSL Repeater 2P - Route 66 Communications

Crocus SHDSL Repeater 2P - Route 66 Communications

Crocus SHDSL Repeater 2P - Route 66 Communications

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

12 <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> Chapter 2<br />

User manual<br />

Installing and connecting the <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong><br />

2.3 Selecting a site<br />

Indoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong><br />

Indoor use only! Install the unit in an area free of extreme temperatures, humidity, shock and vibration.<br />

Position it so that you can easily see and access the front panel. Leave enough clearance at the back<br />

for cables and wires. Position the unit within the correct distances for the different accesses and, if powered<br />

locally, within 2m of a power outlet.<br />

Outdoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong><br />

Outdoor use is allowed. Protection against moisture, vibration and impact.<br />

2.4 Connection precautions<br />

ESD warning<br />

The circuit boards are sensitive to electrostatic discharges (ESD) and should be handled with care. It is<br />

advisable to ensure an optimal electrical contact between yourself, the working area and a safety ground<br />

before touching any circuit board. Take special care not to touch any component or connector on the<br />

circuit board.<br />

EMC compliant installation<br />

The Telindus access products are fully EMC compliant. To ensure compliance with EMC directive 89/<br />

336/EEC, shielded cables or ferrite beads have to be used.<br />

The connectors of the <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> should only be connected to the following circuit<br />

types:<br />

Connector name Connector label Connector type Circuit type<br />

monitor connector MONITOR subD-9 SELV<br />

<strong>SHDSL</strong> line connector xDSL RJ45 TNV-1 1 /<br />

TNV-3 2<br />

1. without remote powering<br />

2. with remote powering<br />

• SELV (Safety Extra Low Voltage): local connection (e.g. PC to <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong>) or<br />

leased line inside the building.<br />

• TNV-1 (Telecom Network Voltage): leased line outside the building.<br />

• TNV-2: PSTN from PABX inside the building.<br />

• TNV-3: PSTN from operator PABX outside the building.