TotalCare Duo2 Brochure EN - Hill-Rom
TotalCare Duo2 Brochure EN - Hill-Rom
TotalCare Duo2 Brochure EN - Hill-Rom
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Products<br />
<strong>TotalCare</strong> Duo TM 2 Therapy System<br />
A unique combination<br />
for the highly dependent patient<br />
which revolutionises<br />
the caregiver environment.
<strong>TotalCare</strong> Duo TM 2 Therapy System<br />
<strong>TotalCare</strong> Duo TM 2 Therapy System offers a<br />
combination of frame and surface that makes<br />
caring for the most vulnerable patients,<br />
easier and safer.<br />
At a glance:<br />
• Ergonomically designed for<br />
caregiver efficiency.<br />
• Promotes patient mobility to help<br />
improve patient outcomes.<br />
• Provides highly effective wound<br />
prevention and therapy.<br />
• Advanced functions for safer mobilisation.<br />
• Assures patient comfort and safety.<br />
The ergonomically designed frame with one button<br />
FullChair TM and Chair Egress TM positions, promotes<br />
patient mobility, earlier rehabilitation and greater<br />
independence. At the same time, the unique<br />
Duo ® 2 advanced low-pressure surface provides<br />
pressure relief and comfort, in any position.<br />
<strong>TotalCare</strong> Duo TM 2 Therapy System is suitable for<br />
patients with or at risk of skin damage including<br />
burns, pressure sores, plastic surgery and many other<br />
conditions.<br />
This winning combination of positioning and pressure<br />
relief makes a real difference to both patients and<br />
caregivers. By reducing the need for manual lifting and<br />
handling, <strong>TotalCare</strong> Duo TM 2 Therapy System increases<br />
caregiver efficiency and improves patient outcomes.
Products<br />
Duo ® 2 Therapy<br />
Line of site Controls<br />
TM<br />
Angle Indicators<br />
Independent<br />
Head Zone<br />
OneStep TM Side rail<br />
Release Mechanism<br />
Removable Headboard<br />
for CPR Support<br />
Central<br />
Point-Of-Care TM Area<br />
Patient<br />
Controls<br />
Collapsible<br />
Transport Handles<br />
Body Zone<br />
with microcushions<br />
for<br />
the lumbar<br />
WallGuard TM<br />
Bumper System<br />
Brake and<br />
Steer System<br />
HandsFree TM Emergency<br />
CPR & Trendelenburg<br />
Release Mechanism<br />
Manual<br />
Foot Pedal<br />
Independent<br />
Real-Heel TM Zone<br />
with microcushions<br />
Drainage Bag<br />
Holders<br />
15.2 cm diameter<br />
casters
The ultimate support system<br />
for managing your<br />
highly dependent patients.
Products<br />
The integral Duo ® 2 support surface offers two<br />
clinically accepted therapies in one proven product.<br />
Duo ® 2 has a unique pressure control technology<br />
called De-Teq ®<br />
De-Teq ® constantly monitors the patient’s weight and<br />
position providing the lowest possible pressures to optimise<br />
pressure relief for all patients in all positions, thus ensuring<br />
a high TCPO 2<br />
at all times even in high risk patients.<br />
Continuous mode<br />
Alternating mode<br />
Air in or out<br />
The unique Real-Heel TM zone, with its optimised<br />
1 in 2 cycle and its 12 micro-cushions, adjusts<br />
independently to the body zone.<br />
Air pressure<br />
Distance<br />
Air<br />
Protex TM cover<br />
Sensing zone<br />
The fully enclosed Protex TM mattress cover is easily<br />
cleaned. It is smooth, waterproof, moisture vapour<br />
permeable and bacteriostatic. The two way stretch<br />
material conforms to the patient’s body shape and<br />
reduces friction and shear.<br />
HandsFree TM features<br />
HandsFree TM emergency CPR and Trendelenburg release<br />
mechanism for instant care, even from the FullChair TM<br />
position. Once activated, the one step CPR function<br />
modifies the bed position and deflates the mattress<br />
within 10 seconds.<br />
Shearless Pivot TM Patient Position Mechanism<br />
The unique mechanism combining the articulation<br />
of the frame and the surface minimises shear forces,<br />
reducing migration of the patient towards the foot<br />
of the bed. Repositioning is minimised and patient<br />
comfort maximised.<br />
Transport mode<br />
Transport mode allows patient support for two hours.<br />
Simply unplug the bed power supply and silence<br />
the alarm.<br />
Protex TM mattress cover<br />
Shearless Pivot TM<br />
HandsFree TM CPR<br />
Transport mode
The <strong>TotalCare</strong> Duo TM 2 Therapy System is<br />
designed for the caregiver,<br />
head to foot.
Products<br />
FullChair TM Patient Position Mechanism<br />
and Chair Egress TM Position<br />
Using one-button chair positioning, a single caregiver<br />
can place the patient in a chair position, providing<br />
an ideal position to:<br />
• enhance respiratory mechanics<br />
• ease nutritional difficulties<br />
• improve psychological status<br />
thereby effectively accelerating their rehabilitation.<br />
By removing the footboard, the caregiver can aid the<br />
patient to weight bear or egress the bed reducing<br />
the risk of injury. Safe, simple and effective.<br />
Point-of-Care TM side rail controls<br />
FullChair TM Patient Position<br />
All controls, information and alarm systems are<br />
conveniently placed around the Point-of-Care TM<br />
by the patient’s side. The OneStep TM design side rails<br />
can be released using a single hand, tucking away<br />
to allow unrestricted access to the patient and a zero<br />
transfer gap. The optional Patient Weigh Scale and<br />
bed exit alarm can also be consulted from the<br />
Point-of-Care TM side rail controls.<br />
FlexAfoot TM Retractable Foot Mechanism<br />
The foot section of bed and surface can be retracted<br />
and extended in both chair and supine positions to<br />
provide support for the patient’s feet or to facilitate<br />
transport in small spaces.<br />
Chair Egress TM Position<br />
FlexAfoot TM Retractable<br />
Foot Mechanism<br />
Adjustable height<br />
OneStep TM side rails<br />
Patient Controls<br />
The integrated, easy-to-use<br />
patient controls promote patient<br />
independence in positioning, allowing<br />
the caregiver more time for skilled tasks.
Products<br />
<strong>TotalCare</strong> Duo TM 2 Therapy System<br />
Technical Data<br />
FRAME SPECIFICATIONS<br />
WIDTH<br />
Side rails up: .........................................................................101.6 cm<br />
Side rails down: ..................................................................... 91.4 cm<br />
L<strong>EN</strong>GTH<br />
Without bumpers: ................................................................233.7 cm<br />
With bumpers: .....................................................................237.5 cm<br />
FOOT RETRACTION:..............................................................30.5 cm<br />
RADIOLUC<strong>EN</strong>T WINDOW<br />
Length x width: ......................................................58.4 cm x 55.9 cm<br />
HEIGHT OF SIDE RAIL<br />
Above mattress:......................................................................> 22 cm<br />
Above deck:..........................................................................37.47 cm<br />
CHAIR POSITIONING<br />
Chair Position:<br />
50º - 65º ................................................................................ Head<br />
0º - 10º ....................................................................................Seat<br />
30º - 70º ..................................................................................Foot<br />
Chair Egress TM Position:<br />
65º - 75º ................................................................................ Head<br />
0º - 10º ....................................................................................Seat<br />
70º - 85º ..................................................................................Foot<br />
BED ARTICULATION<br />
Trendelenburg/Reverse-Trendelenburg: .......................................15º/15º<br />
Emergency Trendelenburg: ........................................................... 20º<br />
Head Section: ................................................................................ 75º<br />
Knee: ............................................................................................ 20º<br />
Automatic Contour: ...................................................................... 10º<br />
CASTER SIZE: ........................................................................15.2 cm<br />
HEIGHT<br />
Minimum height:....................................................................44.5 cm<br />
Maximum height: ...................................................................92.7 cm<br />
WHEELBASE: ......................................................................106.7 cm<br />
WHEELTRACK<br />
Head: .....................................................................................65.4 cm<br />
Foot: ......................................................................................59.7 cm<br />
UNDERBED CLEARANCE: .....................................................12.1 cm<br />
SCALE<br />
Compliant with <strong>EN</strong>45501.................................................. class<br />
Accuracy:<br />
5 kg - 25 kg.............................maximum permissible error +/- 0.25 kg<br />
25.5 kg - 100 kg........................maximum permissible error +/- 0.5 kg<br />
100.5 kg - 200 kg....................maximum permissible error +/- 0.75 kg<br />
Weighing Capacity:...................................................................200 kg<br />
Maximum working load frame: .............................................226.8 kg<br />
THERAPY SURFACE SPECIFICATIONS<br />
MATTRESS:<br />
Length (inflated): ........................................................ 182 - 212 cm<br />
Width (inflated): ......................................................................85 cm<br />
Total height (inflated in Therapy mode): ...............................13.5 cm<br />
COVER MATERIAL:<br />
Protex TM (polyurethane coated in knitted nylon)<br />
ELECTRICAL REQUIREM<strong>EN</strong>TS:<br />
Voltage: ..................................................................AC 230 V, 50 Hz<br />
CURR<strong>EN</strong>T<br />
Rated: .................................................................................. 650 mA<br />
Normal: ................................................................................ 350 mA<br />
Stand-by: ............................................................................. 300 mA<br />
Power consumption: ................................................................ 80 W<br />
MAXIMUM PATI<strong>EN</strong>T WEIGHT:<br />
Maximum acceptable patient mass with clinical efficacy for any head<br />
of bed elevation excluding bed necessities and accessories: ... 150 kg<br />
0459<br />
www.hill-rom.com<br />
France .......................................+33 (0)2 97 50 92 12<br />
United Kingdom .......................+44 (0)1530 411000<br />
Deutschland .............................. +49 (0)211/16450-0<br />
Nederland .................................+31 (0)347 32 35 32<br />
Italia ................................................. +39 02-950541<br />
Class IIa Medical device in accordance with the Directive 93/42/EEC.<br />
Suisse/Schweiz .................... +41 (0)21/706 21 30<br />
(deutschsprachig) ............................021/706 21 38<br />
Österreich ........................... +43 (0)2243 / 28550<br />
Ireland .................................. +353 (0)1 413 6005<br />
Iberia ..................................... +34 (0)93 6856000<br />
NOISE LEVEL:<br />
Below 65 dB (A) without mattress system active @ 1 metre.<br />
Below 3 dB (A) above ambient noise with mattress system active @ 1 metre.<br />
Nordic Countries .......................+46 (0)8 564 353 60<br />
Export ..............contact your local <strong>Hill</strong>-<strong>Rom</strong> distributor<br />
....................or contact your Area manager via website<br />
.............................................. or call +1 812 934 8173<br />
Design: www.cadmium.fr PB <strong>TotalCare</strong> Duo TM 2 Therapy System V.001 - 02/05 E.<br />
<strong>Hill</strong>-<strong>Rom</strong> reserves the right to make changes without notice in design, specifications and models. The only warranty <strong>Hill</strong>-<strong>Rom</strong> makes is the express written warranty extended on the sale or rental of its products.<br />
© 2005 <strong>Hill</strong>-<strong>Rom</strong> S.A.S. - ALL RIGHTS RESERVED.<br />
USA & Canada<br />
Western & Eastern Europe<br />
Middle East / Africa /<br />
Sub Indian Continent<br />
Asia Pacific