46: ; Read slave diagnosis 47: SERVICE9 L DIAGNOSE SM00.07 ; (read diagnostic data) 48: JPCN END_CTRL 49: JPP GET_DIAG 7 50: =1 NEW_DIAG SM00.15 ; (new diagnosis requested) 51: END_CTRL NOP 52: 53: ; __________________________________________________________________________ 54: 55: 56: JPK DP_CTRL , _____ 56: BASIS -|_____|- 57: 58: DIAG L BASIS SBM02.00 ; (basic DP_CTRL address) 59: JP END_DIAG 60: L NEW_DIAG SM00.15 ; (new diagnosis requested) 61: JPCN END_DIAG 62: 63: JPP SEE_DIAG 8 64: =0 NEW_DIAG SM00.15 ; (new diagnosis requested) 65: 66: END_DIAG NOP 67: 4 - 60
PC Control 645-12M on PROFIBUS ======== KUBES ======================================================= Program Module IL Project : 645 Network : DPCONTR Module : ERROR No.: 2 created : Dec 09 1997 14:51 User : changed : Jan 22 1998 16:20 Comment: Error analysis ====================================================================== 1: ; Error analysis 2: 3: ERROR L OFF1 SBM02.01 ; (offs. for DP_CTRL data range) 4: CMP 1 ; wrong parameter 5: JP= ERR_1 6: CMP 2 ; not possible 7: JP= ERR_2 8: CMP 7 9: JP= ERR_7 ; internal error 10: 11: ERR_1 L 1 ; prompt "wrong parameter“ 12: JP END_ERR 13: ERR_2 L 2 ; prompt "not possible" 14: JP END_ERR 15: ERR_7 L 3 ; prompt "internal error" 16: JP END_ERR 17: 18: 19: END_ERR = ERR_NR SBM15.01 ; (error number) 20: CLR BASIS SBM02.00 ; (basic DP_CTRL address) 21: 4 - 61
- Page 47 and 48: 4.2. Going online with KUBES PC Con
- Page 49 and 50: PC Control 645-12M used as PLC 4.2.
- Page 51 and 52: 4.3. Memory settings PC Control 645
- Page 53 and 54: 4.4. PLC working method PC Control
- Page 55 and 56: 4.5.1.1. Short description of local
- Page 57 and 58: 4.5.2. External operands as process
- Page 59 and 60: PC Control 645-12M used as PLC 4.5.
- Page 61 and 62: 4.5.3.1. Status of PROFIBUS master
- Page 63 and 64: 4.5.3.2. PEaxx.yy: DP slave status
- Page 65 and 66: 4.6. Summary of commands PC Control
- Page 67 and 68: PC Control 645-12M used as PLC 4.6.
- Page 69 and 70: PC Control 645-12M used as PLC 4.6.
- Page 71 and 72: PC Control 645-12M used as PLC 4.6.
- Page 73 and 74: 4.6.4. Shift and rotation commands
- Page 75 and 76: PC Control 645-12M used as PLC 4.6.
- Page 77 and 78: PC Control 645-12M used as PLC 4.6.
- Page 79 and 80: 4.7. Types of operands PC Control 6
- Page 81 and 82: PC Control 645-12M used as PLC 4.8.
- Page 83 and 84: PC Control 645-12M on PROFIBUS 4.9.
- Page 85 and 86: PC Control 645-12M on PROFIBUS PROF
- Page 87 and 88: PC Control 645-12M on PROFIBUS 4.9.
- Page 89 and 90: 4.9.2.3.1. Choosing a station and g
- Page 91 and 92: 4.9.2.4. Service 7: activate/deacti
- Page 93 and 94: 4.9.2.6. Service 6: synchronise DP
- Page 95 and 96: PC Control 645-12M on PROFIBUS 4.9.
- Page 97: PC Control 645-12M on PROFIBUS ====
- Page 101 and 102: PC Control 645-12M on PROFIBUS ====
- Page 103 and 104: PC Control 645-12M on PROFIBUS ====
- Page 105 and 106: PC Control 645-12M on PROFIBUS ====
- Page 107 and 108: PC Control 645-12M used as PLC 4.10
- Page 109 and 110: 4.10.2. Undervoltage (supply, failu
- Page 111 and 112: PC Control 645-12M used as PLC 4.10
- Page 113 and 114: 4.10.5. Hierarchy error (failure #9
- Page 115 and 116: A. Specifications Specifications A.
- Page 117 and 118: Specifications A.2. Order specifica
- Page 119 and 120: PROFIBUS hardware installation B. P
- Page 121 and 122: PROFIBUS hardware installation B.1.
- Page 123 and 124: PROFIBUS hardware installation B.2.
- Page 125 and 126: PROFIBUS hardware installation B.2.
- Page 127 and 128: PROFIBUS hardware installation Acti
- Page 129 and 130: Index A accumulator 3-9 functional
- Page 131 and 132: Index memory range 3-4 in DOS and W
<strong>PC</strong> <strong>Control</strong> <strong>645</strong>-<strong>12M</strong> on PROFIBUS<br />
======== KUBES =======================================================<br />
Program Module IL<br />
Project : <strong>645</strong><br />
Network : D<strong>PC</strong>ONTR<br />
Module : ERROR No.: 2 created : Dec 09 1997 14:51<br />
User : changed : Jan 22 1998 16:20<br />
Comment: Error analysis<br />
======================================================================<br />
1: ; Error analysis<br />
2:<br />
3: ERROR L OFF1 SBM02.01 ; (offs. for DP_CTRL data range)<br />
4: CMP 1 ; wrong parameter<br />
5: JP= ERR_1<br />
6: CMP 2 ; not possible<br />
7: JP= ERR_2<br />
8: CMP 7<br />
9: JP= ERR_7 ; internal error<br />
10:<br />
11: ERR_1 L 1 ; prompt "wrong parameter“<br />
12: JP END_ERR<br />
13: ERR_2 L 2 ; prompt "not possible"<br />
14: JP END_ERR<br />
15: ERR_7 L 3 ; prompt "internal error"<br />
16: JP END_ERR<br />
17:<br />
18:<br />
19: END_ERR = ERR_NR SBM15.01 ; (error number)<br />
20: CLR BASIS SBM02.00 ; (basic DP_CTRL address)<br />
21:<br />
4 - 61