<strong>PC</strong> <strong>Control</strong> <strong>645</strong>-<strong>12M</strong> used as PLC<br />
-- Select line "SLAVE_1..." by clicking on it.<br />
-- Click on the "DP options" button.<br />
-- From the upper listbox, choose the GSD file of<br />
<strong>Profi</strong> I/O 690E+<br />
-- Click on "Accept"<br />
Settings<br />
• Diagnosis memory:<br />
In the case of <strong>PC</strong> control <strong>645</strong>-<strong>12M</strong>, diagnosis memory<br />
settings have no effect at this point.<br />
Refer to chapter "4.9.2.8. Service 9...".<br />
• Passive mode<br />
means that, during the PROFIBUS-DP startup procedure,<br />
this DP slave is disabled and there is no communication<br />
with this device.<br />
Refer to chapter "4.9.2.4. Service 7...".<br />
• Byte operands only<br />
means that the inputs and outputs of this DP slave are<br />
written into the process image as byte operands. This relieves<br />
the load on the process image memory.<br />
• Watchdog <strong>Control</strong> and Group-Ident<br />
Refer to the technical documentation of the DP slave (here:<br />
instruction manual E 408 D, <strong>Profi</strong> I/O 690E+).<br />
4 - 5