Reliability / safety 2.4.2. To be observed during maintenance and servicing - - Precaution regulation VBG 4.0 must be observed, and section 8 (Admissible deviations during working on parts) in particular, when measuring or checking a controller in a power-up condition. - - Repairs must only be made by specially trained Kuhnke staff (usually in the main factory in Malente). Warranty expires in every other case. - - Spare parts: Only use parts approved of by Kuhnke. Only genuine Kuhnke modules must be used in modular controllers. - - Modules must only be connected to or disconnected from the controller with no voltage supplied. Otherwise they may be destroyed or (possibly not immediately recognisably!) suffer a negative impact on their functionality. - - Always deposit batteries and accumulators as hazardous waste. 2 - 4
Reliability / safety 2.5. Electromagnetic compatibility 2.5.1. Definition Electromagnetic compatibility is the ability of a device to function satisfactorily in its electromagnetic environment without itself causing any electromagnetic interference that would be intolerable to other devices in this environment. Of all known phenomena of electromagnetic noise, only a certain range occurs at the location of a given device. This noise depends on the exact location. It is defined in the relevant product standards. The international standard regulating construction and degree of noise resistance of programmable logic controllers is IEC 1131-2 which, in Europe, has been the basis for European standard EN 61131-2. 2.5.2. Resistance to interference -- Electrostatic discharge, ESD in acc. with IEC 801-2, 3rd degree of sharpness -- Irradiation resistance of the device, HF in acc. with IEC 801-3, 3rd degree of sharpness -- Fast transient interference, burst in acc. with IEC 801-4, 3rd degree of sharpness -- Immunity to damped oscillations in acc. with IEC 255-4 (1 MHz, 1 kV) 2 - 5
- Page 1 and 2: Kuhnke Electronics Instruction Manu
- Page 3 and 4: Table of contents Table of contents
- Page 5 and 6: Table of contents 4.5.2. External o
- Page 7 and 8: Table of contents B. PROFIBUS hardw
- Page 9 and 10: 1. Purpose of PC Control 645-12M In
- Page 11 and 12: Introduction Advantages of decentra
- Page 13 and 14: Introduction VEBES VEBES, the netwo
- Page 15 and 16: 2. Reliability and safety Reliabili
- Page 17: Reliability / safety 2.4. Safety Ou
- Page 21 and 22: 2.5.5. Protection against external
- Page 23 and 24: 3. Hardware Hardware 3.1. Design 17
- Page 25 and 26: Hardware 3.2.2.1. Uninterrupted swi
- Page 27 and 28: Hardware 3.4.2. Setting the reset t
- Page 29 and 30: Hardware 3.5. Interfaces 3.5.1. V.2
- Page 31 and 32: Hardware 3.6. Memory PC Control 645
- Page 33 and 34: Hardware 3.8.2. How to avoid addres
- Page 35 and 36: Hardware -- Activate the "Memory" o
- Page 37 and 38: Hardware To reserve a memory range
- Page 39 and 40: i n 0 2 4LV o g 0 2 4LV o Sa t da t
- Page 41 and 42: PC Control 645-12M used as PLC 4.1.
- Page 43 and 44: PC Control 645-12M used as PLC -- S
- Page 45 and 46: PC Control 645-12M used as PLC The
- Page 47 and 48: 4.2. Going online with KUBES PC Con
- Page 49 and 50: PC Control 645-12M used as PLC 4.2.
- Page 51 and 52: 4.3. Memory settings PC Control 645
- Page 53 and 54: 4.4. PLC working method PC Control
- Page 55 and 56: 4.5.1.1. Short description of local
- Page 57 and 58: 4.5.2. External operands as process
- Page 59 and 60: PC Control 645-12M used as PLC 4.5.
- Page 61 and 62: 4.5.3.1. Status of PROFIBUS master
- Page 63 and 64: 4.5.3.2. PEaxx.yy: DP slave status
- Page 65 and 66: 4.6. Summary of commands PC Control
- Page 67 and 68: PC Control 645-12M used as PLC 4.6.
Reliability / safety<br />
2.4.2. To be observed during maintenance and servicing<br />
- - Precaution regulation VBG 4.0 must be observed, and<br />
section 8 (Admissible deviations during working on parts)<br />
in particular, when measuring or checking a controller in<br />
a power-up condition.<br />
- - Repairs must only be made by specially trained <strong>Kuhnke</strong><br />
staff (usually in the main factory in Malente). Warranty<br />
expires in every other case.<br />
- - Spare parts:<br />
Only use parts approved of by <strong>Kuhnke</strong>. Only genuine<br />
<strong>Kuhnke</strong> modules must be used in modular controllers.<br />
- - Modules must only be connected to or disconnected from<br />
the controller with no voltage supplied. Otherwise they<br />
may be destroyed or (possibly not immediately recognisably!)<br />
suffer a negative impact on their functionality.<br />
- - Always deposit batteries and accumulators as hazardous<br />
waste.<br />
2 - 4