PC Control / Profi Control 645-12M Instruction Manual pdf - Kuhnke
PC Control / Profi Control 645-12M Instruction Manual pdf - Kuhnke PC Control / Profi Control 645-12M Instruction Manual pdf - Kuhnke
======== KUBES ======================================================= Program Module IL Project : 645 Network : DPCONTR Module : DE_ACT No.: 3 created : Dec 09 1997 15:04 User : changed : Jan 22 1998 16:20 Comment: ACTIVATE and DEACTIVATE ====================================================================== 1: ; __________________________________________________________________________ 2: ; Parameters shared by activation and deactivation processes 3: ; __________________________________________________________________________ 4: 5: L 7 6: = BASIS SBM02.00 ; (basic DP_CTRL address) 7: ; Clear error no. 8: L 0 9: = OFF1 SBM02.01 ; (offs. for DP_CTRL data range) 10: ; Slave address 11: L 9 12: = OFF2 SBM02.02 ; (offs. for DP_CTRL data range) 13: ; __________________________________________________________________________ 14: ; Activate slave 15: ; __________________________________________________________________________ 16: 17: D7_0 L ACTIVE SM00.00 ; (activate slave) 18: JPCN D7_1 19: 20: L PL00.01 ; >=128 activates 21: = OFF3 SBM02.03 ;(offs. for DP_CTRL data range) 22: 23: =0 ACTIVE SM00.00 ; (activate slave) 24: JP END 25: ; __________________________________________________________________________ 26: ; Deactivate slave 27: ; __________________________________________________________________________ 28: 29: D7_1 L PL00.00 ; < 128 deactivates 30: = OFF3 SBM02.03 ;(offs. for DP_CTRL data range) 31: =0 DEACTIVE SM00.01 ; (deactivate slave) 32: 33: END NOP 4 - 62
PC Control 645-12M on PROFIBUS ======== KUBES ======================================================= Program Module IL Project : 645 Network : DPCONTR Module : UN_FREEZ No.: 4 created : Dec 09 1997 15:14 User : changed : Jan 22 1998 16:21 Comment: FREEZE and UNFREEZE ====================================================================== 1: ; __________________________________________________________________________ 2: ; Parameters shared by freezing and unfreezing processes 3: ; __________________________________________________________________________ 4: 5: L 5 6: = BASIS SBM02.00 ; (basic DP_CTRL address) 7: ; Clear error no. 8: L 0 9: = OFF1 SBM02.01 ;(offs. for DP_CTRL data range) 10: ; Slave address 11: L 9 12: = OFF2 SBM02.02 ;(offs. for DP_CTRL data range) 13: ; Choose group 14: L 1 15: = OFF3 SBM02.03 ;(offs. for DP_CTRL data range) 16: ; __________________________________________________________________________ 17: ; Put slave into FREEZE mode 18: ; __________________________________________________________________________ 19: 20: D5_0 L FREEZE SM00.02 ; (freeze inputs) 21: JPCN D5_1 22: L PL00.01 ; >= 128 freezes 23: = OFF4 SBM02.04 ;(offs. for DP_CTRL data range) 24: =0 FREEZE SM00.02 ; (freeze inputs) 25: JP END 26: ; __________________________________________________________________________ 27: ; Put slave into UNFREEZE mode 28: ; __________________________________________________________________________ 29: 30: D5_1 L PL00.00 ; < 128 unfreezes 31: = OFF4 SBM02.04 ;(offs. for DP_CTRL data range) 32: =0 UNFREEZE SM00.03 ; (update inputs) 33: 34: END NOP 4 - 63
- Page 49 and 50: PC Control 645-12M used as PLC 4.2.
- Page 51 and 52: 4.3. Memory settings PC Control 645
- Page 53 and 54: 4.4. PLC working method PC Control
- Page 55 and 56: 4.5.1.1. Short description of local
- Page 57 and 58: 4.5.2. External operands as process
- Page 59 and 60: PC Control 645-12M used as PLC 4.5.
- Page 61 and 62: 4.5.3.1. Status of PROFIBUS master
- Page 63 and 64: 4.5.3.2. PEaxx.yy: DP slave status
- Page 65 and 66: 4.6. Summary of commands PC Control
- Page 67 and 68: PC Control 645-12M used as PLC 4.6.
- Page 69 and 70: PC Control 645-12M used as PLC 4.6.
- Page 71 and 72: PC Control 645-12M used as PLC 4.6.
- Page 73 and 74: 4.6.4. Shift and rotation commands
- Page 75 and 76: PC Control 645-12M used as PLC 4.6.
- Page 77 and 78: PC Control 645-12M used as PLC 4.6.
- Page 79 and 80: 4.7. Types of operands PC Control 6
- Page 81 and 82: PC Control 645-12M used as PLC 4.8.
- Page 83 and 84: PC Control 645-12M on PROFIBUS 4.9.
- Page 85 and 86: PC Control 645-12M on PROFIBUS PROF
- Page 87 and 88: PC Control 645-12M on PROFIBUS 4.9.
- Page 89 and 90: 4.9.2.3.1. Choosing a station and g
- Page 91 and 92: 4.9.2.4. Service 7: activate/deacti
- Page 93 and 94: 4.9.2.6. Service 6: synchronise DP
- Page 95 and 96: PC Control 645-12M on PROFIBUS 4.9.
- Page 97 and 98: PC Control 645-12M on PROFIBUS ====
- Page 99: PC Control 645-12M on PROFIBUS ====
- Page 103 and 104: PC Control 645-12M on PROFIBUS ====
- Page 105 and 106: PC Control 645-12M on PROFIBUS ====
- Page 107 and 108: PC Control 645-12M used as PLC 4.10
- Page 109 and 110: 4.10.2. Undervoltage (supply, failu
- Page 111 and 112: PC Control 645-12M used as PLC 4.10
- Page 113 and 114: 4.10.5. Hierarchy error (failure #9
- Page 115 and 116: A. Specifications Specifications A.
- Page 117 and 118: Specifications A.2. Order specifica
- Page 119 and 120: PROFIBUS hardware installation B. P
- Page 121 and 122: PROFIBUS hardware installation B.1.
- Page 123 and 124: PROFIBUS hardware installation B.2.
- Page 125 and 126: PROFIBUS hardware installation B.2.
- Page 127 and 128: PROFIBUS hardware installation Acti
- Page 129 and 130: Index A accumulator 3-9 functional
- Page 131 and 132: Index memory range 3-4 in DOS and W
======== KUBES =======================================================<br />
Program Module IL<br />
Project : <strong>645</strong><br />
Network : D<strong>PC</strong>ONTR<br />
Module : DE_ACT No.: 3 created : Dec 09 1997 15:04<br />
User : changed : Jan 22 1998 16:20<br />
Comment: ACTIVATE and DEACTIVATE<br />
======================================================================<br />
1: ;<br />
__________________________________________________________________________<br />
2: ; Parameters shared by activation and deactivation processes<br />
3: ;<br />
__________________________________________________________________________<br />
4:<br />
5: L 7<br />
6: = BASIS SBM02.00 ; (basic DP_CTRL address)<br />
7: ; Clear error no.<br />
8: L 0<br />
9: = OFF1 SBM02.01 ; (offs. for DP_CTRL data range)<br />
10: ; Slave address<br />
11: L 9<br />
12: = OFF2 SBM02.02 ; (offs. for DP_CTRL data range)<br />
13: ;<br />
__________________________________________________________________________<br />
14: ; Activate slave<br />
15: ;<br />
__________________________________________________________________________<br />
16:<br />
17: D7_0 L ACTIVE SM00.00 ; (activate slave)<br />
18: J<strong>PC</strong>N D7_1<br />
19:<br />
20: L PL00.01 ; >=128 activates<br />
21: = OFF3 SBM02.03 ;(offs. for DP_CTRL data range)<br />
22:<br />
23: =0 ACTIVE SM00.00 ; (activate slave)<br />
24: JP END<br />
25: ;<br />
__________________________________________________________________________<br />
26: ; Deactivate slave<br />
27: ;<br />
__________________________________________________________________________<br />
28:<br />
29: D7_1 L PL00.00 ; < 128 deactivates<br />
30: = OFF3 SBM02.03 ;(offs. for DP_CTRL data range)<br />
31: =0 DEACTIVE SM00.01 ; (deactivate slave)<br />
32:<br />
33: END NOP<br />
4 - 62