4. Coil heating control<br />

1) This control function heats the compressor by turning on the stopped compressor instead of a case heater.<br />

It purposes to prevent stagnation of the refrigerant inside of the compressor.<br />

2) As usual, turn on power of the compressor for the specified time before a test run after installation;<br />

otherwise a trouble of the compressor may be caused.<br />

As same as a test run, it is recommended to turn on power of the compressor beforehand when starting<br />

operation after power of the compressor has been interrupted and left as it is for a long time.<br />

3) A judgment for electricity is performed by TD and TO sensors.<br />

If TO sensor is defective, a backup control is automatically performed by TE sensor.<br />

For a case of defective TO sensor, judge it with outdoor LED display.<br />

4) For every model, the power is turned off when TD is 30°C or more.<br />

• Power-ON<br />

condition<br />

TD