No.<br />

Item<br />

Outline of specifications<br />

Remarks<br />

22<br />

8°C heating/<br />

Frost protective<br />

operation<br />

1) This functional is intended for the cold latitudes and performs<br />

objective heating operation (8°C heating operation).<br />

2) This function is valid only for combination with the outdoor<br />

units (Super Digital Inverter (SDI) 4-series outdoor units).<br />

3) Using the indoor DN code [D1] (1 bit), Valid/Invalid of this<br />

function is set up at the customer’s side.<br />

∗ The setup by DN code is Invalid [0]/Valid [1] and Invalid [0]<br />

has been set at the shipment.<br />

4) This operation is the heating operation which sets 8°C as<br />

the setup temperature of the target.<br />

5) This function starts operation by pushing temperature<br />

button during heating operation; besides by pushing<br />

button for 4 seconds or more after temperature<br />

reached the minimum set temperature.<br />

6) To stop/release this operation, select and execute one from<br />

the following operations.<br />

Push button: Heating operation (18°C setting)<br />

continues.<br />

‚ Push [START/STOP] button: Air conditioner stops.<br />

(Heating 18°C operation at the next start)<br />

MODE<br />

ƒ Push : Other operation mode is selected and the<br />

operation continues.<br />

7) As the setup temperature is 8°C and the human heating is not<br />

targeted, the cold air discharge preventive control (Item 7) is<br />

made invalid to suppress the intermittent operation.<br />

8) The settings of the air direction and air volume are<br />

changeable during this operation.<br />

9) The indoor fan stops to protect the compressor for<br />

2 minutes after start of heating operation (Thermo-ON) by<br />

this function.<br />

In a group connection,<br />

if there is even one<br />

combination with other<br />

unit, “This function is not<br />

provided.” is displayed.<br />

The setup temperature<br />

jumps from [18] to [8].<br />

– 73 –