SUPER DIGITAL
SUPER DIGITAL
SUPER DIGITAL
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Revised 2: Jun., 2008<br />
No.<br />
Item<br />
Outline of specifications<br />
Remarks<br />
12<br />
Louver control<br />
(Continued):<br />
In case of 4-way<br />
Discharge<br />
Cassette type<br />
• If there is the locked louver in the unit, [ ] goes on the<br />
remote controller screen.<br />
• While the following controls are performed, the louvers<br />
operate even if executing the louver lock.<br />
Control which ignores lock<br />
Objective louver No.<br />
For the setting<br />
operation, refer to<br />
[How to set louver<br />
lock] of Installation<br />
Manual.<br />
‚<br />
ƒ<br />
„<br />
…<br />
†<br />
Operation stop<br />
When heating operation started<br />
Heating thermo. OFF<br />
During defrost operation<br />
Initialize operation<br />
Self-clean operation<br />
Full-close position<br />
Horizontal discharge position<br />
Horizontal discharge position<br />
Horizontal discharge position<br />
Full-close position<br />
Horizontal discharge position<br />
• The real louver corresponding to the louver No. displayed on the<br />
remote controller screen during setting of louver lock operates<br />
swinging.<br />
It is position check<br />
operation and it<br />
does not link with<br />
the real louver and<br />
air direction setup<br />
(Illustration on the<br />
remote controller<br />
screen).<br />
13<br />
HA control<br />
1) This control is connected to TV control or remote start/stop<br />
I/F, etc, and start/stop are available by HA signal input from<br />
the remote position.<br />
2) This control outputs start/stop status to HA output terminal.<br />
3) I/O specifications conform to JEMA regulations.<br />
4) This control outputs [Operation OFF (STOP) signal] to HA<br />
output terminal while self-cleaning works. However selection of<br />
[Operation ON (Operating) signal] is possible by changing<br />
[0000 (At shipment)] of Item code (DN) [CC] to [0001]. In this<br />
case, if HA is input during self-clean operation during operation<br />
of the air conditioner, the self-clean operation is not performed.<br />
(Unit stops.)<br />
In the group operation,<br />
use this control<br />
by connecting to<br />
either master or<br />
follower indoor unit.<br />
14<br />
Frequency fixed<br />
operation (Test run)<br />
<br />
1) When pushing [CHK] button for 4 seconds or more, [TEST]<br />
is displayed on the display screen and the mode enters in<br />
Test run mode.<br />
2) Push [ON/OFF] button.<br />
3) Using [MODE] button, set the mode to [COOL] or [HEAT].<br />
• Do not use other mode than [COOL]/[HEAT] mode.<br />
• During test run operation, the temperature cannot be<br />
adjusted.<br />
• An error is detected as usual.<br />
• A frequency fixed operation is performed.<br />
4) After the test run, push [ON/OFF] button to stop the operation.<br />
(Display in the display part is same as the procedure in Item 1.)<br />
5) Push [CHK] button to clear the test run mode.<br />
([TEST] display in the display part disappears and the<br />
status returns to the normal stop status.)<br />
Command frequency<br />
is approximately [S7]<br />
15 Filter sign display<br />
(Except wireless<br />
type)<br />
∗ It is provided on<br />
the separately<br />
sold type<br />
TCB-AX21E2.<br />
1) The operation time of the indoor fan is calculated, the filter reset<br />
signal is sent to the remote controller when the specified time<br />
(2500H) has passed, and it is displayed on LCD.<br />
2) When the filter reset signal has been received from the<br />
remote controller, time of the calculation timer is cleared.<br />
In this case, the measurement time is reset if the specified<br />
time has passed, and display on LCD disappears.<br />
[FILTER<br />
] goes on.<br />
– 70 –