No.<br />
Item<br />
Outline of specifications<br />
Remarks<br />
12<br />
Louver control<br />
(Continued):<br />
In case of 4-way<br />
Discharge<br />
Cassette type<br />
<br />
• For the Swing mode, the following three types of modes are<br />
selectable and settable by keeping Swing/Direction SWING/FIX<br />
button pushed for 4 seconds or more on the remote controller.<br />
Standard (4 pieces: same phase) swing<br />
→ Data: [0001 (At shipment)]<br />
When Swing operation is selected, four louvers align at the<br />
horizontal discharge position and then start the Swing<br />
operation at the same time.<br />
‚ Dual swing → Data: [0002]<br />
When operation is selected, the louvers of louver No. [01]<br />
and [03] move to the horizontal discharge position, the<br />
louvers of louver No. [02] and [04] move to the downward<br />
discharge position and then start the Swing operation at<br />
the same time.<br />
ƒ Cycle swing → Data: [0003]<br />
When operation is selected, the louver No. [01] moves to<br />
the horizontal discharge position, [03] to the downward<br />
discharge position, [02] and [04] to the middle position and<br />
then start the Swing operation at the same time.<br />
• Three types of the swing modes can be also selected and set<br />
by the setup data of Item code (DN) [F0].<br />
• In case of selecting the Swing mode, “Dual swing” or “Cycle<br />
swing”, the following numerals is displayed at the center of<br />
the remote controller screen for approx. 3 seconds when<br />
SWING/FIX<br />
button was pushed to select [SWING].<br />
(No display for the standard swing)<br />
On the remote controller<br />
before the wired<br />
remote controller<br />
(RBC-AMT31E), the<br />
mode cannot be moved<br />
to the select mode<br />
even if pushing SWING/FIX<br />
button for a long time.<br />
Carry out setting<br />
operation during stop of<br />
the unit; otherwise the<br />
unit stops operation.<br />
The standard swing<br />
performs the same<br />
swing operation as the<br />
present operation<br />
(2 series).<br />
For the setting operation,<br />
refer to [How to<br />
set up type of the<br />
swings] in Item “Setup<br />
at local site/Others”.<br />
On the remote controller<br />
before the wired remote<br />
controller<br />
(RBC-AMT31E),<br />
flashing showing the<br />
Swing mode is not<br />
indicated.<br />
Alternate lighting<br />
(0.5 sec.)<br />
Alternate lighting<br />
(0.5 sec.)<br />
Dual swing<br />
Cycle swing<br />
<br />
• For the air direction setup for each discharge port, the louver<br />
position can be locked during the normal operation.<br />
• An arbitrary air direction of an arbitrary louver can be<br />
UNIT LOUVER<br />
registered and set by keeping button pushed for<br />
4 seconds or more on the remote controller.<br />
• The louver lock can be set by registering the setup data to<br />
Item code (DN) [F1] to [F4] according to the following table.<br />
Item code<br />
F1<br />
F2<br />
F3<br />
F4<br />
Objective louver No.<br />
01<br />
02<br />
03<br />
04<br />
Setup data<br />
0000: Release (At shipment)<br />
0001: Horizontal discharge position<br />
~<br />
0005: Downward discharge position<br />
On the remote controller<br />
before the wired<br />
remote controller<br />
(RBC-AMT31E),<br />
UNIT LOUVER<br />
button is not<br />
provided.<br />
Carry out setting<br />
operation during stop of<br />
the unit; otherwise the<br />
unit stops operation.<br />
– 69 –