Revised 2: Jun., 2008<br />
No.<br />
Item<br />
Outline of specifications<br />
Remarks<br />
6<br />
Air speed<br />
selection<br />
(Continued):<br />
In case of 4-way<br />
Discharge<br />
Cassette type<br />
Item code<br />
[5d]<br />
SW501 (1)/(2)<br />
Tap<br />
F1<br />
F2<br />
F3<br />
F4<br />
F5<br />
F6<br />
F7<br />
F8<br />
F9<br />
FA<br />
FB<br />
FC<br />
FD<br />
Standard Type 1 Type 3 Type 6<br />
0 1 3 6<br />
OFF/OFF ON/OFF OFF/ON ON/ON<br />
HEAT COOL HEAT COOL HEAT COOL HEAT COOL<br />
HH HH HH HH<br />
HH HH<br />
H+ H+, H H+, H<br />
H+, H H+, H<br />
L+, L L+, L<br />
H+<br />
HH<br />
H<br />
HH H L+ L+<br />
H+ H+ L L<br />
H L+<br />
H L+ L<br />
L+ L<br />
L+ L<br />
L<br />
UL UL UL UL<br />
Selection of high<br />
ceiling type<br />
Item code:<br />
[5d] or selection of<br />
high ceiling on P.C.<br />
board SW501<br />
Tap<br />
F1<br />
F2<br />
F3<br />
F4<br />
F5<br />
F6<br />
F7<br />
F8<br />
F9<br />
FA<br />
FB<br />
FC<br />
FD<br />
SM56 SM80 SM110 SM140 SM160<br />
Revolution speed (rpm)<br />
610 630 700 700 700<br />
550 590 670 670 670<br />
500 530 660 660 660<br />
450 470 640 650 650<br />
400 450 620 640 640<br />
390 440 610 630 630<br />
370 410 550 560 580<br />
350 380 490 490 530<br />
340 370 480 480 520<br />
330 350 450 460 490<br />
320 330 400 430 450<br />
310 320 400 420 440<br />
250 250 300 300 300<br />
3) In heating operation, the mode changes to [UL] if thermostat<br />
is turned off.<br />
4) If Ta ≥ 25°C when heating operation has started and when<br />
defrost operation has been cleared, the air conditioner<br />
operates with (H) mode or higher mode for 1 minute after Tc<br />
entered in E zone of cool air discharge preventive control<br />
(Item 7).<br />
5) In automatic cooling/heating operation, the revolution<br />
frequency of (HH) is set larger than that in the standard<br />
cooling/heating operation.<br />
Ta<br />
(˚C)<br />
47<br />
F5<br />
F4<br />
However the revolution<br />
frequency is restricted in the<br />
automatic heating operation as<br />
shown in the following figure.<br />
However only when<br />
the high ceiling<br />
selection is set to<br />
[Standard]<br />
42<br />
F5<br />
6) Self-clean operation<br />
When performing self-clean operation after stopping the<br />
cooling operation, the mode becomes [UL] (210 rpm).<br />
[Self-clean<br />
displayed.<br />
] is<br />
– 64 –