Revised 2: Jun., 2008<br />

No.<br />

Item<br />

Outline of specifications<br />

Remarks<br />

6<br />

Air speed<br />

selection<br />

(Continued):<br />

In case of 4-way<br />

Discharge<br />

Cassette type<br />

Item code<br />

[5d]<br />

SW501 (1)/(2)<br />

Tap<br />

F1<br />

F2<br />

F3<br />

F4<br />

F5<br />

F6<br />

F7<br />

F8<br />

F9<br />

FA<br />

FB<br />

FC<br />

FD<br />

Standard Type 1 Type 3 Type 6<br />

0 1 3 6<br />

OFF/OFF ON/OFF OFF/ON ON/ON<br />

HEAT COOL HEAT COOL HEAT COOL HEAT COOL<br />

HH HH HH HH<br />

HH HH<br />

H+ H+, H H+, H<br />

H+, H H+, H<br />

L+, L L+, L<br />

H+<br />

HH<br />

H<br />

HH H L+ L+<br />

H+ H+ L L<br />

H L+<br />

H L+ L<br />

L+ L<br />

L+ L<br />

L<br />

UL UL UL UL<br />

Selection of high<br />

ceiling type<br />

Item code:<br />

[5d] or selection of<br />

high ceiling on P.C.<br />

board SW501<br />

Tap<br />

F1<br />

F2<br />

F3<br />

F4<br />

F5<br />

F6<br />

F7<br />

F8<br />

F9<br />

FA<br />

FB<br />

FC<br />

FD<br />

SM56 SM80 SM110 SM140 SM160<br />

Revolution speed (rpm)<br />

610 630 700 700 700<br />

550 590 670 670 670<br />

500 530 660 660 660<br />

450 470 640 650 650<br />

400 450 620 640 640<br />

390 440 610 630 630<br />

370 410 550 560 580<br />

350 380 490 490 530<br />

340 370 480 480 520<br />

330 350 450 460 490<br />

320 330 400 430 450<br />

310 320 400 420 440<br />

250 250 300 300 300<br />

3) In heating operation, the mode changes to [UL] if thermostat<br />

is turned off.<br />

4) If Ta ≥ 25°C when heating operation has started and when<br />

defrost operation has been cleared, the air conditioner<br />

operates with (H) mode or higher mode for 1 minute after Tc<br />

entered in E zone of cool air discharge preventive control<br />

(Item 7).<br />

5) In automatic cooling/heating operation, the revolution<br />

frequency of (HH) is set larger than that in the standard<br />

cooling/heating operation.<br />

Ta<br />

(˚C)<br />

47<br />

F5<br />

F4<br />

However the revolution<br />

frequency is restricted in the<br />

automatic heating operation as<br />

shown in the following figure.<br />

However only when<br />

the high ceiling<br />

selection is set to<br />

[Standard]<br />

42<br />

F5<br />

6) Self-clean operation<br />

When performing self-clean operation after stopping the<br />

cooling operation, the mode becomes [UL] (210 rpm).<br />

[Self-clean<br />

displayed.<br />

] is<br />

– 64 –

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!