No.<br />

Item<br />

Outline of specifications<br />

Remarks<br />

6<br />

Air speed selection<br />

1) Operation with (HH), (H), (L) or [AUTO] mode is carried<br />

out by the command from the remote controller.<br />

HH > H+ > H > L+ ><br />

L > UL<br />

2) When the air speed mode [AUTO] is selected, the air<br />

speed varies by the difference between Ta and Ts.<br />

<br />

Ta (˚C)<br />

+3.0<br />

+2.5<br />

+2.0<br />

+1.5<br />

+1.0<br />

+0.5<br />

Tsc<br />

–0.5<br />

HH<br />

(HH)<br />

H+ (HH)<br />

H (HH)<br />

L+ (H+)<br />

L (H)<br />

L (H)<br />

L (L+)<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

G<br />

• Controlling operation in case when thermo of remote<br />

controller works is same as a case when thermo of the<br />

body works.<br />

• If the air speed has been changed once, it is not changed<br />

for 3 minutes. However when the air volume is exchanged,<br />

the air speed changes.<br />

• When cooling operation has started, select a downward<br />

slope for the air speed, that is, the high position.<br />

• If the temperature is just on the difference boundary, the<br />

air speed does not change.<br />

• Mode in the parentheses indicates one in automatic<br />

cooling operation.<br />

<br />

Ta (˚C)<br />

(–0.5) –1.0<br />

(0) Tsh<br />

(+0.5) +1.0<br />

(+1.0) +2.0<br />

(+1.5) +3.0<br />

(+2.0) +4.0<br />

L (L+)<br />

L+ (H)<br />

H (H+)<br />

H+<br />

(HH)<br />

HH<br />

(HH)<br />

E<br />

D<br />

C<br />

B<br />

A<br />

Value in the parentheses indicates one when thermostat of<br />

the remote controller works.<br />

Value without parentheses indicates one when thermostat of<br />

the body works.<br />

• If the air speed has been changed once, it is not changed<br />

for 1 minute. However when the air speed I exchanged, the<br />

air speed changes.<br />

• When heating operation has started, select an upward<br />

slope for the air speed, that is, the high position.<br />

• If the temperature is just on the difference boundary, the<br />

air speed does not change.<br />

• Mode in the parentheses indicates one in automatic<br />

heating operation.<br />

• In Tc ≥ 60°C, the air speed increases by 1 step.<br />

Tc: Indoor heat<br />

exchanger sensor<br />

temperature<br />