27.03.2014 Views

SUPER DIGITAL

SUPER DIGITAL

SUPER DIGITAL

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

8-1. Indoor Controller Block Diagram<br />

8. INDOOR CONTROL CIRCUIT<br />

8-1-1. Connection of Main (Sub) Remote Controller<br />

Main (sub) master remote controller (Max. 2 units)<br />

Weekly timer<br />

Display LCD<br />

Function setup<br />

Display LCD<br />

LCD driver<br />

Display LED<br />

MCU<br />

Key switch<br />

DC5V<br />

CN2<br />

CN1<br />

MCU<br />

Function setup<br />

Key switch<br />

Remote controller<br />

communication circuit<br />

Power circuit<br />

∗3<br />

Power<br />

circuit<br />

DC5V<br />

Secondary<br />

battery<br />

Indoor unit<br />

#1 (Master)<br />

A<br />

B<br />

#2<br />

(Follower)<br />

A<br />

B<br />

#3<br />

(Follower)<br />

A<br />

B<br />

Indoor control P.C. board (MCC-1570)<br />

DC20V<br />

DC5V<br />

DC12V<br />

Remote controller<br />

communication circuit<br />

EEPROM<br />

TA sensor<br />

× 4<br />

Louver<br />

motor<br />

Humidifier output<br />

Driver<br />

MCU<br />

TC sensor<br />

TCJ sensor<br />

Float input<br />

Same as left<br />

∗2<br />

Same as left<br />

∗2<br />

Drain<br />

pump<br />

HA<br />

Indoor<br />

fan motor<br />

DC280V<br />

Power circuit<br />

MCU<br />

Fan motor<br />

control circuit<br />

Outside<br />

output<br />

Run<br />

Warning<br />

Defrost<br />

Thermo. ON<br />

COOL<br />

HEAT<br />

FAN<br />

AC<br />

synchronous<br />

signal input circuit<br />

Auto grille<br />

panel<br />

Serial send/<br />

receive circuit<br />

1<br />

2<br />

3<br />

1<br />

2<br />

3<br />

1<br />

2<br />

3<br />

Outdoor unit<br />

Outdoor unit<br />

* Case of TCC-LINK adapter<br />

Case of TCC-LINK adapter<br />

(Option)<br />

TCC-LINK<br />

adapter P.C. board<br />

(MCC-1440)<br />

1<br />

2<br />

3<br />

Up to 8 units are connectable. ∗1<br />

∗1 However Max.7 units are connectable in<br />

case of mounting network adapter when two<br />

main (sub) remote controllers are connected.<br />

∗2 The network adapter is mounted to only 1 unit.<br />

TCC-LINK adapter is mounted to the master unit.<br />

∗3 Connection of the weekly timer to the sub<br />

remote controller is unavailable.<br />

TCC-LINK<br />

Central controller<br />

(Option)<br />

U3<br />

U4<br />

TCC-LINK<br />

communication circuit<br />

Outdoor unit<br />

– 58 –

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!