6-2. Outdoor Unit (Parts Ratings)<br />
RAV-SP1104AT-E, RAV-SP1104ATZ-E, RAV-SP1104ATZG-E<br />
RAV-SP1404AT-E, RAV-SP1404ATZ-E, RAV-SP1404ATZG-E<br />
Revised 2: Jun., 2008<br />
No.<br />
Parts name<br />
Type<br />
Specifications<br />
1<br />
Compressor<br />
DA422A3F-25M<br />
—<br />
2<br />
Outdoor fan motor<br />
ICF-280-A100-1<br />
Output 100W<br />
3<br />
Reactor<br />
CH-62<br />
5.7mH, 18.5A<br />
4<br />
4-way valve coil<br />
VHV-01AP552B1<br />
AC240V<br />
5<br />
PMV coil<br />
UKV-A038<br />
DC12V<br />
6<br />
P.C. board<br />
MCC-1571<br />
AC220 – 240V<br />
7<br />
Fuse (Mounted on P.C. board)<br />
—<br />
AC250V, 25A<br />
8<br />
Fuse (Mounted on P.C. board)<br />
—<br />
AC250V, 10A<br />
9<br />
Fuse (Mounted on P.C. board)<br />
—<br />
AC250V, 3.15A<br />
10<br />
Outdoor temp. sensor (TO sensor)<br />
—<br />
10 kΩ at 25°C<br />
11<br />
Heat exchanger sensor (Te sensor)<br />
—<br />
10 kΩ at 25°C<br />
12<br />
Discharge temp. sensor (Td sensor)<br />
—<br />
50 kΩ at 25°C<br />
13<br />
Heat exchanger mid. Temp sensor (TL sensor)<br />
—<br />
10 kΩ at 25°C<br />
14<br />
Compressor thermo. (Protection)<br />
US-622<br />
OFF: 125 ± 4°C, ON: 90 ± 5°C<br />
RAV-SP404AT-E, RAV-SP404ATZ-E, RAV-SP404ATZG-E<br />
RAV-SP454AT-E, RAV-SP454ATZ-E, RAV-SP454ATZG-E<br />
No.<br />
Parts name<br />
Type<br />
Specifications<br />
1<br />
Fan motor<br />
ICF-140-43-4R<br />
Output (Rated) 43W<br />
2<br />
Compressor<br />
DA150A1F-20F<br />
3 phase, 4P, 1100W<br />
3<br />
Reactor<br />
CH-57<br />
10mH, 16A<br />
4<br />
Outdoor temp. sensor (To sensor)<br />
—<br />
10 kΩ at 25°C<br />
5<br />
Heat exchanger sensor (Te sensor)<br />
—<br />
10 kΩ at 25°C<br />
6<br />
Suction temp. sensor (Ts sensor)<br />
—<br />
10 kΩ at 25°C<br />
7<br />
Discharge temp. sensor (Td sensor)<br />
—<br />
50 kΩ at 25°C<br />
8<br />
Fuse (Switching power (Protect))<br />
—<br />
T3.15A, AC 250V<br />
9<br />
Fuse (Inverter, input (Current protect))<br />
—<br />
AC240V<br />
10<br />
4-way valve solenoid coil<br />
STF-01AJ502E1<br />
—<br />
11<br />
Compressor thermo. (Protection)<br />
US-622<br />
OFF: 125 ± 4°C, ON: 90 ± 5°C<br />
12<br />
Coil (Pulse Motor Valve)<br />
CAM-MD12TF-6<br />
—<br />
6-3. Accessory Separate Sold Parts<br />
RBC-U31PG (W, WS)-E (Ceiling panel), RBC-U31PGS (W, WS)-E (Ceiling panel)<br />
RAV-SM564UT-E, RAV-SM804UT-E, RAV-SM1104UT-E, RAV-SM1404UT-E, RAV-SM1604UT-E<br />
No.<br />
Parts name<br />
Type<br />
Specifications<br />
1<br />
Motor-louver<br />
MP24ZN3N<br />
DC 12 V<br />
2<br />
– 45 –