3-2. Outdoor Unit<br />
RAV-SP1104AT-E, SP1104ATZ-E, SP1104ATZG-E, RAV-SP1404AT-E, SP1404ATZ-E, SP1404ATZG-E<br />
TS sensor<br />
TO sensor<br />
TL sensor<br />
PMV<br />
Strainer<br />
Check joint<br />
Cooling: High pressure<br />
Heating: Low pressure<br />
TE sensor<br />
Capillary<br />
Ø4 ×Ø3 (6 pcs.)<br />
TD sensor<br />
Heat exchanger<br />
Ø8, 2 rows, 52 stages<br />
FP1.45, flat fin<br />
In cooling operation<br />
In heating operation<br />
Distributor<br />
Strainer<br />
Refrigerant pipe<br />
at liquid side Ø9.5<br />
Packed valve<br />
Refrigerant pipe<br />
at gas side Ø15.9<br />
Ball valve<br />
Muffler<br />
Ø25 × L180<br />
Cooling: Low pressure<br />
Heating: High pressure<br />
Accumulator<br />
(2500cc)<br />
Rotary compressor<br />
(DA422A3F-25M)<br />
Ø25 × L210<br />
RAV-SP1104AT-E, RAV-SP1104ATZ-E, RAV-SP1104ATZG-E<br />
Pressure<br />
(MPa) (kg/cm²g)<br />
Pd Ps Pd Ps<br />
Pipe surface temperature (°C)<br />
Indoor heat Outdoor heat<br />
Discharge Suction<br />
exchanger exchanger<br />
(TD) (TS) (TC) (TL) (TE)<br />
Compressor<br />
drive revolution<br />
frequency<br />
(rps)<br />
Indoor<br />
fan<br />
Indoor/Outdoor<br />
temp. conditions<br />
(DB/WB) (°C)<br />
Indoor<br />
Outdoor<br />
Standard<br />
2.57 0.99 26.2 10.1<br />
66 14 12 44 38<br />
38<br />
HIGH<br />
27/19 35/–<br />
Cooling<br />
Overload<br />
3.30 1.09 33.7 11.1<br />
78 9 13 49 43<br />
53<br />
HIGH<br />
32/24 43/–<br />
Low load<br />
1.74 0.75 17.8 7.7<br />
46 7 5 32 25<br />
21<br />
LOW<br />
18/15.5 –5/–<br />
Standard<br />
2.32 0.73 23.7 7.4<br />
65 3 39 2 3<br />
43<br />
HIGH<br />
20/– 7/6<br />
Heating<br />
Overload<br />
3.22 1.17 32.9 11.9<br />
73 19 54 14 15<br />
26<br />
LOW<br />
30/– 24/18<br />
Low load<br />
2.17 0.30 22.1 3.1<br />
87 –15 38 –14 –13<br />
71<br />
HIGH<br />
15/– –15/–<br />
*<br />
This compressor has 4-pole motor. The value when compressor frequency (Hz) is measured by a clamp<br />
meter becomes 2 times of No. of compressor revolutions (rps).<br />
RAV-SP1404AT-E, RAV-SP1404ATZ-E, RAV-SP1404ATZG-E<br />
Pressure<br />
(MPa) (kg/cm²g)<br />
Pd Ps Pd Ps<br />
Pipe surface temperature (°C)<br />
Indoor heat Outdoor heat<br />
Discharge Suction<br />
exchanger exchanger<br />
(TD) (TS) (TC) (TL) (TE)<br />
Compressor<br />
drive revolution<br />
frequency<br />
(rps)<br />
Indoor<br />
fan<br />
Indoor/Outdoor<br />
temp. conditions<br />
(DB/WB) (°C)<br />
Indoor<br />
Outdoor<br />
Standard<br />
2.72 0.90 27.8 9.2<br />
73 12 10 46 38<br />
51<br />
HIGH<br />
27/19 35/–<br />
Cooling<br />
Overload<br />
3.34 1.07 34.1 10.9<br />
80 9 13 51 45<br />
55<br />
HIGH<br />
32/24 43/–<br />
Low load<br />
1.75 0.76 17.9 7.8<br />
47 8 6 33 25<br />
21<br />
LOW<br />
18/15.5 –5/–<br />
Standard<br />
2.59 0.69 26.4 7.0<br />
75 3 43 2 2<br />
53<br />
HIGH<br />
20/– 7/6<br />
Heating<br />
Overload<br />
3.13 1.05 31.9 10.7<br />
72 16 53 12 13<br />
26<br />
LOW<br />
30/– 24/18<br />
Low load<br />
2.40 0.21 24.5 2.1<br />
97 –22 42 –19 –18<br />
90<br />
HIGH<br />
15/– –15/–<br />
*<br />
This compressor has 4-pole motor. The value when compressor frequency (Hz) is measured by a clamp<br />
meter becomes two times of No. of compressor revolutions (rps).<br />
– 37 –