No.<br />
Part name<br />
Procedure<br />
Remarks<br />
7<br />
Fan motor<br />
1. Detachment<br />
1) Perform works 1. of 2 , 1. of 3 , and 1. of 6 .<br />
2) Remove lead wires which are connected to the<br />
following connectors of P.C. board assembly.<br />
NOTE)<br />
Unlock locks of the housing, and then remove the<br />
connectors.<br />
CN333 : Fan motor power supply (5P: White)<br />
CN334 : Detection of fan motor (3P: White)<br />
Remove tie wrap which fixes lead wires.<br />
3) Remove the noise filter from lead wire to detect fan<br />
motor position.<br />
4) Take off screws of fan motor fixing bracket.<br />
Earth wires of the motor are tightened together.<br />
(Ø5 × 10, 2 pcs)<br />
Remove tie wrap which fixes the lead wires.<br />
5) Remove fixing bracket of the fan motor by holding it<br />
with hands so that the fan motor does not fall down.<br />
2. Attachment<br />
1) Mount the fan motor as before in order, Fan motor<br />
Earth lead<br />
→ Fixing bracket of fan motor → Noise filter → Lead wire process → E-cover.<br />
NOTE)<br />
Check there is no missing or poor contact of the connectors. Check also that the multi blade<br />
fan turns surely and smoothly, and check together-tightening of motor earth.<br />
8<br />
Under panel<br />
Drain pan<br />
assembly<br />
1. Detachment<br />
1) Take off the drain cap and drain the drain water<br />
accumulated in the drain pan assembly.<br />
In case of natural drain model, drain the drain water<br />
by taking off hose band and drain hose.<br />
NOTE)<br />
When taking off drain cap and drain hose, be sure<br />
receive drain water in a bucket, etc.<br />
2) Take off screws fixing the under panel while holding<br />
it to remove. (Ø4 × 10, 8 pcs)<br />
Drain cap or drain hose<br />
Under panel<br />
NOTE)<br />
Be careful that sheeting metal does not fall when<br />
removing the under panel.<br />
3) Pull out the drain pan assy. by holding handle at<br />
lower part.<br />
NOTE)<br />
When pulling out the drain pan assy, never pull out the<br />
drain socket by drawing it with hands. If doing so, water<br />
leak may be caused.<br />
4) Pull out it to some extent, lay hand on the bump at<br />
suction side, and then remove the drain pan assembly.<br />
2. Attachment<br />
1) Hook and attach the drain pan assy. to the flange at<br />
discharge side, and then push in.<br />
2) Using screws taken off in procedure 1. 2) of 8 ,<br />
attach under panel by holding with hands.<br />
3) Attach drain cap, hose band, and drain hose as before,<br />
which were taken off in procedure 1. 1) of 8 .<br />
NOTE)<br />
Finally, be sure to check there is no water leakage from<br />
each attached part.<br />
Drain pan assembly<br />
Never hold and pull<br />
the drain socket.<br />
NO GOOD<br />