No.<br />
Part name<br />
Procedure<br />
Remarks<br />
3<br />
E-cover<br />
1. Detachment<br />
1) Perform work 1. of 2 .<br />
2) Take off screws fixing E-cover, and then<br />
remove hooks of the hooking part by lifting<br />
up. (Ø4 × 10, 2 pcs)<br />
2. Attachment<br />
1) Hang on E-cover to hooks of the hooking<br />
part so that it does not fall down.<br />
E-cover<br />
NOTE)<br />
Be sure not to catch TA sensor in the E-cover;<br />
otherwise the equipment cannot operate<br />
correctly.<br />
2) Using the screws taken off in procedure 1. 2)<br />
of 3 , attach E-cover while holding it with<br />
hands without clearance.<br />
NOTE)<br />
If there is clearance, dust may enter in the<br />
electric parts box.<br />
TA sensor<br />
2 screws<br />
Hooking part<br />
E-cover<br />
4<br />
E-box<br />
1. Detachment<br />
1) Perform works 1. of 2 and 1. of 3 .<br />
Clamp<br />
Clamp<br />
2) Remove clamps and tie wrap at upper part<br />
of the photo. (Drain pump incorporated<br />
model: 3 positions)<br />
(Natural drain model: 2 positions)<br />
3) Take off screws fixing E-box. (Ø4 × 10, 2 pcs)<br />
Tie wrap<br />
E-box does not fall down under condition<br />
that screws are taken off.<br />
4) Remove the E-box over sheeting metal<br />
which was fixed with screws.<br />
2. Attachment<br />
1) Insert hooks of E-box into the hooking part<br />
of the main body.<br />
2) Store E-box as before, and then attach it by<br />
using screws taken off in procedure 1. 3) of<br />
4 .<br />
Drain pump 2 screws<br />
Lead wire:<br />
For only drain pump incorporated model<br />
NOTE)<br />
Be sure to fix surely as before the lead wires of<br />
which clamps and tie wrap were taken off.<br />
NOTE)<br />
Check that lead wires of the drain pump do not<br />
reach the fan so that they are not caught in the<br />
fan, and then fix them.<br />
(In case of drain pump incorporated model)<br />
– 192 –