2) Error display<br />

<br />

The error which is generating at present and the latest error (Latest error information including present)<br />

can be confirmed by lighting LED D800 toD804 on the outdoor control P.C. board.<br />

a) When all DIP switch SW803 are OFF, the status of error which is generating at present is displayed.<br />

b) only of DIP switch SW803 is turned on, the error which generated before<br />

(Latest error information including present) is displayed.a)<br />

c) If there is an error, any of LED D800 to D804 goes on. (Display 1)<br />

d) When pushing the pushdown button switch SW800 for approx. 1 second, the display is exchanged.<br />

(Display 2)<br />

e) When pushing SW800 again or after 2 minutes, the status returns to that of Display .<br />

Present error<br />

SW803<br />

ON<br />

2 3 4<br />

1<br />

Latest error<br />

SW803<br />

ON<br />

2 3 4<br />

1<br />

(Legend)<br />

l D800 (Yellow)<br />

l D801 (Yellow)<br />

¥ D802 (Yellow)<br />

l D803 (Yellow)<br />

l D804 (Yellow)<br />

¡ D805 (Green)<br />

l : Go off, ¡ : Go on, ¥ : Flash<br />

Display 1)<br />

(Initial display)<br />

lllll¡<br />

¡¡ll¡¡<br />

ll¡l¡¡<br />

l¡¡l¡¡<br />

¡¡¡l¡¡<br />

Display 2)<br />

(SW800 operation)<br />

lllll¡<br />

ll¥ll¡<br />

l¥¥ll¡<br />

¥¥¥ll¡<br />

lll¥l¡<br />

ll¥¥l¡<br />

¥l¥¥l¡<br />

¥¥¥¥l¡<br />

¥¥¥¥¥¡<br />

¥llll¡<br />

l¥lll¡<br />

¥¥lll¡<br />

ll¥ll¡<br />

l¥l¥l¡<br />

¥l¥¥¥¡<br />

¥¥¥¥¥¡<br />

¥¥lll¡<br />

¥l¥ll¡<br />

¥¥¥ll¡<br />

¥¥¥¥l¡<br />

¥¥ll¥¡<br />

ll¥l¥¡<br />

l¥¥l¥¡<br />

l¥l¥¥¡<br />

¥l¥¥¥¡<br />

Error contents<br />

Normal<br />

Discharge temp. sensor (TD) error<br />

Heat exchanger temp. sensor (TE) error<br />

Heat exchanger temp. sensor (TL) error<br />

Outside temp. sensor (TO) error<br />

Suction temp. sensor (TS) error<br />

Heat sink temp. sensor (TH) error<br />

Heat exchanger sensor (TE, TS) miswiring<br />

EEPROM error<br />

Compressor break down<br />

Compressor lock<br />

Current detection circuit error<br />

Case thermostat operation<br />

Model unset<br />

Communication error between MCU<br />

Other error (Compressor disorder, etc.)<br />

Discharge temp. error<br />

Power supply error<br />

Heat sink overheat error<br />

Gas leak detection<br />

4-way valve reverse error<br />

High pressure protective operation<br />

Fan system error<br />

Driving element short-circuit<br />

Position detection circuit erro<br />

Wired remote controller<br />

Error code<br />

—<br />

F04<br />

F06<br />

F06, F07<br />

F08<br />

F06, F12<br />

F13, L29<br />

F06, F15<br />

F31, L29<br />

H01<br />

H02<br />

H03<br />

H04, P04<br />

L10, L29<br />

L29<br />

Error is not determined.<br />

P03<br />

P04, P05<br />

P07, L29<br />

P15, L29<br />

P19, L29<br />

P04, P20<br />

P22<br />

P26<br />

P29<br />

∗ As the error code displayed on the wired remote controller may differ according to type of indoor model, multiple<br />

codes are described.<br />