Revised 2: Jun., 2008<br />
Table 1. Setting data (CODE No. table (example))<br />
DN<br />
Item<br />
Setting data<br />
Factory-set value<br />
01<br />
Filter sign lighting time<br />
Depending on Type<br />
02<br />
Filter pollution leve<br />
0000: standard<br />
03<br />
Central control address<br />
0099: Not determined<br />
06<br />
Heating suction temperature shift<br />
0002: +2°C<br />
(flooring installation type: 0)<br />
OF<br />
Cooling only<br />
0000: Heat pump<br />
10<br />
Type<br />
Depending on model type<br />
11<br />
Indoor unit capacity<br />
Depending on capacity type<br />
12<br />
System address<br />
0099: Not determined<br />
13<br />
Indoor unit address<br />
0099: Not determined<br />
14<br />
Group address<br />
0099: Not determined<br />
19<br />
Louver type (wind direction adjustment)<br />
Depending on Type.<br />
1E<br />
Temperature range of cooling/heating<br />
automatic SW control point<br />
0003: 3 deg (Ts ± 1.5)<br />
28<br />
Power failure automatic recovery<br />
0000: None<br />
2A<br />
Option/Abnormal input (CN70) SW<br />
0002: Humidifier<br />
2b<br />
Thermo output SW (T10 ƒ )<br />
0000: Thermo ON<br />
31<br />
Ventilation fan (standalone)<br />
0000: Not available<br />
32<br />
Sensor SW (Selection of static pressure)<br />
0000: Body sensor<br />
40<br />
Humidifier control (+ drain pump control)<br />
0003: Humidifier ON + Pump OFF<br />
5d<br />
High ceiling SW<br />
0000: Standard<br />
60<br />
Timer setting (wired remote controller)<br />
0000: Available<br />
C2<br />
Demand setting<br />
(outdoor unit current demand)<br />
0075: 75 %<br />
d0<br />
Remote controller operation save function<br />
0001: Enable<br />
d3<br />
Rotation number of the self-clean operation<br />
0001: 210ypm(at self-clean operation)<br />
d1<br />
Frost protection function<br />
0000: None<br />
F0<br />
Swing mode<br />
0001: Standard<br />
F1<br />
Louver fixing position (Flap No. 1)<br />
0000: Not fixed<br />
F2<br />
Louver fixing position (Flap No. 2)<br />
0000: Not fixed<br />
F3<br />
Louver fixing position (Flap No. 3)<br />
0000: Not fixed<br />
F4<br />
Louver fixing position (Flap No. 4)<br />
0000: Not fixed<br />
Table 2. Type: CODE No. 10<br />
Table 3.<br />
Indoor unit capacity: CODE No. 11<br />
Setting data<br />
0001 *1 * 2<br />
0005<br />
Type<br />
4-way Air Discharge Cassette Type<br />
Slim Duct Type<br />
Type name abb.<br />
RAV-SM∗∗∗UT-E<br />
RAV-SM∗∗∗SDT-E<br />
∗1 EEPROM initial value on the P.C. board for indoor unit servicing<br />
∗2<br />
CAUTION<br />
<br />
For the above models, set the CODE No. to “ CE ” and the setting<br />
data 0000 (initial) to “0001”.<br />
Setting data<br />
0000∗<br />
0006<br />
0007<br />
0009<br />
0012<br />
0015<br />
0017<br />
0018<br />
Type<br />
Disable<br />
40<br />
45<br />
56<br />
80<br />
110<br />
140<br />
160<br />
∗ EEPROM initial value on the P.C. board<br />
for indoor unit servicing.<br />