27.03.2014 Views

SUPER DIGITAL

SUPER DIGITAL

SUPER DIGITAL

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Temperature sensor Temperature – Resistance value characteristic table<br />

T A, T C, T CJ, T E, T S, T O sensors<br />

Representative value<br />

T emperature<br />

(°C)<br />

0<br />

10<br />

20<br />

25<br />

30<br />

40<br />

50<br />

60<br />

70<br />

80<br />

90<br />

100<br />

(Minimum value)<br />

Resistance value (kΩ)<br />

(Standard value) (Maximum value)<br />

32.33 33.80 35.30<br />

19.63 20.35 21.09<br />

12.23 12.59 12.95<br />

9.75 10.00 10.25<br />

7.764 7.990 8.218<br />

5.013 5.192 5.375<br />

3.312 3.451 3.594<br />

2.236 2.343 2.454<br />

1.540 1.623 1.709<br />

1.082 1.146 1.213<br />

0.7740 0.8237 0.8761<br />

0.5634 0.6023 0.6434<br />

T D, T L sensors<br />

Representative value<br />

T emperature<br />

(°C)<br />

0<br />

10<br />

20<br />

25<br />

30<br />

40<br />

50<br />

60<br />

70<br />

80<br />

90<br />

100<br />

(Minimum value)<br />

Resistance value (kΩ)<br />

(Standard value) (Maximum value)<br />

150.5 161.3 172.7<br />

92.76 99.05 105.6<br />

58.61 62.36 66.26<br />

47.01 49.93 52.97<br />

37.93 40.22 42.59<br />

25.12 26.55 28.03<br />

17.00 17.92 18.86<br />

11.74 12.34 12.95<br />

8.269 8.668 9.074<br />

5.925 6.195 6.470<br />

4.321 4.507 4.696<br />

3.205 3.336 3.468<br />

T A, T C, T CJ, T E, T S, T O sensors<br />

40<br />

Resistance (kΩ)<br />

30<br />

20<br />

10<br />

0<br />

0<br />

10 20 30 40 50 60 70 80 90 100<br />

Temperature (˚C)<br />

T D, T L sensors<br />

Resistance (kΩ) (50˚C or lower)<br />

200<br />

150<br />

100<br />

50<br />

0<br />

0<br />

20<br />

15<br />

10<br />

5<br />

0<br />

10 20 30 40 50 60 70 80 90 100<br />

Resistance (kΩ) (50˚C or higher)<br />

Temperature (˚C)<br />

∗ As TH sensor (Outdoor unit heat sink temp. sensor) is incorporated in the outdoor control P.C. board, the resistance<br />

value cannot be measured.<br />

– 140 –

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!