10-2-8. Check Code List (Indoor)<br />

(Indoor unit detected)<br />

Check code indication<br />

TCC-LINK central &<br />

Wired remote controller<br />

E03<br />

E04<br />

E08<br />

E10<br />

E18<br />

F01<br />

F02<br />

F10<br />

F29<br />

L03<br />

L07<br />

L08<br />

L09<br />

L20<br />

L30<br />

P01<br />

P10<br />

P12<br />

P19<br />

P31<br />

(Remote controller detected)<br />

<br />

¡ : Go on, ¥ : Flash, l : Go off ALT (Alternate): Alternate flashing when there are two flashing LED SIM (Simultaneous): Simultaneous flashing when there are two flashing LED<br />

Sensor lamp indication<br />

Block indication<br />

Operation Timer Ready Flash<br />

¥ l l<br />

l l ¥<br />

¥ l l<br />

¥ l l<br />

¥ l l<br />

¥ ¥ l ALT<br />

¥ ¥ l ALT<br />

¥ ¥ l ALT<br />

¥ ¥ l SIM<br />

¥ l ¥ SIM<br />

¥ l ¥ SIM<br />

¥ l ¥ SIM<br />

¥ l ¥ SIM<br />

¥ ¡ ¥ SIM<br />

¥ ¡ ¥ SIM<br />

l ¥ ¥ ALT<br />

l ¥ ¥ ALT<br />

l ¥ ¥ ALT<br />

¥ l ¥ ALT<br />

¥ l ¥ ALT<br />

Representative defective position<br />

Regular communication error between indoor and<br />

remote controller<br />

Indoor/Outdoor serial error<br />

Duplicated indoor addresses ²<br />

Communication error between indoor MCU<br />

Regular communication error between<br />

indoor master and follower units<br />

Indoor unit, Heat exchanger (TCJ) error<br />

Indoor unit, Heat exchanger (TC) error<br />

Indoor unit, Room temp. sensor (TA) error<br />

Indoor unit, other indoor P.C. board error<br />

Duplicated setting of indoor group master unit ²<br />

There is group cable in individual indoor unit. ²<br />

Unset indoor group address ²<br />

Unset indoor capacity<br />

Duplicated central control system address<br />

Outside error input to indoor unit (Interlock)<br />

Indoor unit, AC fan error<br />

Indoor unit, overflow detection<br />

Indoor unit, DC fan error<br />

4-way valve system error<br />

Other indoor unit error<br />

Explanation of error contents<br />

No communication from remote controller and network adapter<br />

(Also no communication from central control system)<br />

There is error on serial communication between indoor and outdoor units<br />

Same address as yours was detected.<br />

MCU communication error between main motor and micro computer<br />

Regular communication between indoor master and follower units is impossible,<br />

Communication between twin master (main) and follower (sub) units is impossible.<br />

Open/short was detected on heat exchanger (TCJ).<br />

Open/short was detected on heat exchanger (TC).<br />

Open/short was detected on room temp. sensor (TA).<br />

EEPROM error (Other error may be detected. If no error, automatic address is repeated.<br />

There are multiple master units in a group.<br />

When even one group connection indoor unit exists in individual indoor unit.<br />

Indoor group address is unset.<br />

Capacity of indoor unit is unset.<br />

Duplicated setting of central control system address<br />

Abnormal stop by outside error (CN80) input<br />

An error of indoor AC fan was detected. (Fan motor thermal relay worked.)<br />

Float switch worked.<br />

Indoor DC fan error (Over-current/Lock, etc.) was detected.<br />

In heating operation, an error was detected by temp. down of indoor heat exchanger sensor.<br />

Follower unit in group cannot operate by warning from [E03/L03/L07/L08] of master unit.<br />

Air conditioner operation<br />

Automatic<br />

reset<br />

Operation<br />

continuation<br />

¡ ×<br />

¡ ×<br />

¡ ×<br />

¡ ×<br />

¡ ×<br />

¡ ×<br />

¡ ×<br />

¡ ×<br />

× ×<br />

× ×<br />

× ×<br />

× ×<br />

× ×<br />

¡ ×<br />

× ×<br />

× ×<br />

× ×<br />

× ×<br />

¡ ×<br />

¡ ×<br />

² When this warning was detected before group construction/address check finish at power supply was turned on, the mode shifts automatically to AUTO address setup mode.<br />

Check code indication<br />

Wired remote controller<br />

E01<br />

E02<br />

E09<br />

Sensor lamp indication<br />

Block indication<br />

Operation Timer Ready Flash<br />

¥ l l<br />

¥ l l<br />

¥ l l<br />

Representative defective position<br />

No master remote controller, Remote controller<br />

communication (Receive) error<br />

Remote controller communication (Send) error<br />

Duplicated master remote controller<br />

Explanation of error contents<br />

Signal cannot be received from indoor unit. Master remote controller was not set.<br />

(including 2 remote controllers)<br />

Signal cannot be sent to indoor unit.<br />

In 2-remote controller control, both were set as master. (Indoor master unit stops warning<br />

and follower unit continues operation.)<br />

Air conditioner operation<br />

Automatic<br />

reset<br />

Operation<br />

continuation<br />

— —<br />

— —<br />

×<br />

(Central control devices detected)<br />

NOTE:<br />

Check code indication<br />

TCC-LINK central<br />

C05<br />

C06<br />

C12<br />

P30<br />

Sensor lamp indication<br />

Block indication<br />

Operation Timer Ready Flash<br />

Is not displayed.<br />

(Common use of<br />

remote controller, etc.)<br />

—<br />

By warning unit<br />

(Above-mentioned)<br />

Representative defective position<br />

Central control system communication (send) error<br />

Central control system communication (receive) error<br />

General-purpose device control interface batched warning<br />

Group follower unit is defective.<br />

Explanation of error contents<br />

Signal sending operation of central control system is impossible.<br />

There are multiple same central devices. (AI-NET)<br />

Signal receiving operation of central control system is impossible.<br />

An error on device connected to general-purpose device control interface of exclusive to<br />

TCC-LINK/AI-NET<br />

Group follower unit is defective.<br />

(For remote controller, above-mentioned [∗∗∗] details are displayed with unit No.<br />

Even for the same contents of error such as communication error, the display of check code may differ according to detection device.<br />

When remote controller or central controller detects an error, it is not necessarily related to operation of the air conditioner. In this list, the check codes that outdoor unit detects are not described.<br />

Air conditioner operation<br />

Automatic<br />

reset<br />

Operation<br />

continuation<br />

— —<br />

— —<br />

— —<br />

— —

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!