Check<br />
code<br />
Outdoor<br />
LED display<br />
<br />
Check and troubleshooting<br />
(Item without special mention Indicates part of outdoor unit.)<br />
[P03]<br />
<br />
¡ ¥<br />
¡ ¥<br />
¡ l<br />
l l<br />
¡ l<br />
¡ ¡<br />
[Discharge temp. error]<br />
Is there no gas leak?<br />
Is refrigerant charge amount adequate?<br />
YES<br />
Is PMV normal?<br />
YES<br />
Is it not abnormal overload?<br />
NO<br />
NO<br />
YES<br />
Repair defective position.<br />
Recharge refrigerant.<br />
Repair defective position.<br />
Replace defective part.<br />
Correct and clear the cause.<br />
NO<br />
Is CN603 connection normal?<br />
Is resistance value of TD sensor normal?<br />
NO<br />
Correct connector.<br />
Sensor error → Replace<br />
YES<br />
Check outdoor P.C. board.<br />
Defect → Replace<br />
[P04]<br />
[P05]<br />
<br />
l l<br />
l l<br />
¡ ¥<br />
l l<br />
¡ l<br />
¡ ¡<br />
<br />
¡ ¥<br />
¡ l<br />
¡ ¥<br />
l l<br />
¡ l<br />
¡ ¡<br />
<br />
¡ l<br />
¡ l<br />
¡ ¥<br />
l l<br />
¡ ¥<br />
¡ ¡<br />
<br />
¡ ¥<br />
¡ l<br />
¡ ¥<br />
l l<br />
¡ l<br />
¡ ¡<br />
∗ There is a possibility that it is one of the following errors.<br />
Confirm LED on outdoor P.C. board to judge which error it is.<br />
Power supply error (Vdc), High pressure protective operation, Case thermostat<br />
operation<br />
[Case thermostat operation] → Refer to [H04] column.<br />
[Power supply error (Vdc)] → Refer to [P05] column.<br />
[High pressure protective operation] → Refer to [P20] column.<br />
[Power supply error (Voltage error)]<br />
Is there no down or up<br />
of power supply voltage?<br />
(AC198 to 264V)<br />
NO<br />
Check outdoor P.C. board.<br />
Defect → Replace<br />
YES<br />
Confirm electric construction, etc.<br />
– 114 –