OPTIFLUX Handbook
OPTIFLUX Handbook
OPTIFLUX Handbook
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
2 TEMPERATURE LIMITS<br />
<strong>OPTIFLUX</strong><br />
The temperature limits apply under the following conditions:<br />
• The instrument is installed and operated in accordance with the installation directions given<br />
in the installation and operating instructions.<br />
• The instrument is not heated up by any additional heat radiation (direct solar radiation, heat<br />
from adjacent plant parts) so causing it to operate above the permissible ambient<br />
temperature range.<br />
• Insulation is not hindering free ventilation of the signal converter housing.<br />
2.1 <strong>OPTIFLUX</strong> 2000 / 4000<br />
2.1.1 Compact versions<br />
• The <strong>OPTIFLUX</strong> 2300 C / 4300 C is suitable for an ambient temperature range of -40…+60°C.<br />
• For dust hazardous areas, the maximum surface temperature is equal to the process<br />
temperature with a minimum of 85°C.<br />
• The minimum process temperature for all DN sizes is -40°C.<br />
• The maximum process temperature is determined by the temperature class T6/T5...T3 of the<br />
gas hazardous area of concern, the maximum ambient temperature (T a ), and the nominal<br />
diameter. The temperature range is often limited further by the liner type used (refer to the<br />
Quick Start).<br />
DN10...20 ("me")<br />
Temperature class<br />
Max. process temperature Tp [°C]<br />
T a ≤ 40°C 40 < T a ≤ 50°C 50 < T a ≤ 60°C<br />
T6 70 60 -<br />
T5 95 85 60<br />
T4 130 130 60<br />
T3 150 150 1 60<br />
1 140°C for versions with stainless steel converter housing<br />
DN25...150 ("d")<br />
Temperature class<br />
Max. process temperature Tp [°C]<br />
T a ≤ 40°C 40 < T a ≤ 50°C 50 < T a ≤ 60°C<br />
T6 80 80 80 1<br />
T5 95 95 80 1<br />
T4 130 130 80 1<br />
T3 150 150 2 80 1<br />
1 60°C for versions with stainless steel converter housing<br />
2 140°C for versions with stainless steel converter housing<br />
16<br />
www.krohne.com 11/2008 • 7.30948.24.00