OPTIFLUX Handbook

OPTIFLUX Handbook OPTIFLUX Handbook

krohne.downloadcenter.com
from krohne.downloadcenter.com More from this publisher
26.03.2014 Views

1 INTRODUCTION OPTIFLUX EEx marking OPTIFLUX 2000 F / 4000 F: Nominal diameter II 2 GD 10...20 ("me") EEx me ia IIC T6...T3 T85...150°C 25...150 ("d") EEx de ia IIC T6...T3 T85...180°C 200...300 ("qe") EEx qe ia IIC T6...T3 T85...150°C 350...3000 ("e") EEx e ia IIC T6...T3 T85...160°C Optional: 25...150 ("qe") EEx qe ia IIC T5...T3 T85...180°C 10 www.krohne.com 11/2008 • 7.30948.24.00

OPTIFLUX INTRODUCTION 1 1.5 OPTIFLUX 5000 1.5.1 Compact versions OPTIFLUX 5300 C is certified as group II, category 2 GD equipment if fitted with an IFC 300 signal converter without Ex ia signal in/outputs or as a group II, category 2 (1) GD equipment, if fitted with a signal converter with Ex ia signal in/outputs. It is therefore suitable for installation in gas hazardous areas zone 1 and 2, gas group IIC, temperature class T6…T3 and dust hazardous areas zone 21 or zone 22, surface temperature T85...180°C. Additionally, the Ex ia signal in/outputs of the signal converter may run or originate from a Zone 0 gas hazardous area. The sensor is available in "sandwich" and in "flange" version. Converter housing, connection compartment: with power supply (terminals L, N / L+, L-) and I/O connections (terminals A, A+, A-, B, B-, C, C-, D and D-): Ex e (increased safety), optionally: Ex d (Flameproof enclosure). For certain versions of the signal converter the terminals A, A+, A-, B, B-, C, C-, D and D- are additionally Ex ia (Intrinsic safety). Consult the table with CG numbers for details. Converter housing, electronics compartment: Ex d (Flameproof enclosure). EEx marking OPTIFLUX 5300 C "sandwich": Nominal diameter EEx e connection compartment,II 2 GD or II 2(1) GD 2,5...15 EEx dme [ia] IIC T6...T3 T85...150°C EEx d connection compartment,II 2 GD or II 2(1) GD EEx dme [ia] IIC T6...T3 T85...150°C 25...100 EEx de [ia] IIC T6...T3 T85...150°C EEx d [ia] IIC T6...T3 T85...150°C EEx marking OPTIFLUX 5300 C "flange": Nominal diameter EEx e or EEx d connection compartment,II 2 GD or II 2(1) GD 15...100 EEx d e [ia] mb IIC T6...T3 T85...150°C 1.5.2 Field versions OPTIFLUX 5000 F is certified as group II, category 2 GD equipment for gas hazardous areas zone 1 and 2, gas group IIC, temperature classes T6…T3 and dust hazardous areas zone 21 and 22, surface temperature T85...180°C. The connection box contains terminals for the connection of the field current and electrode circuits: Field current circuit, in type of protection "Increased safety" (Ex e), terminals 7,8 and 9: U < 40 V (switched DC voltage, alternately +40 and -40 V), I = 125 mA (injected square wave current), 11/2008 • 7.30948.24.00 www.krohne.com 11

1 INTRODUCTION<br />

<strong>OPTIFLUX</strong><br />

EEx marking <strong>OPTIFLUX</strong> 2000 F / 4000 F:<br />

Nominal diameter<br />

II 2 GD<br />

10...20 ("me") EEx me ia IIC T6...T3 T85...150°C<br />

25...150 ("d") EEx de ia IIC T6...T3 T85...180°C<br />

200...300 ("qe") EEx qe ia IIC T6...T3 T85...150°C<br />

350...3000 ("e") EEx e ia IIC T6...T3 T85...160°C<br />

Optional:<br />

25...150 ("qe") EEx qe ia IIC T5...T3 T85...180°C<br />

10<br />

www.krohne.com 11/2008 • 7.30948.24.00