25.03.2014 Views

Feasibility Study - Kawartha Pine Ridge District School Board

Feasibility Study - Kawartha Pine Ridge District School Board

Feasibility Study - Kawartha Pine Ridge District School Board

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Feasibility</strong> <strong>Study</strong><br />

KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre<br />

09.16.11<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | 1


Contents<br />

Recommendation letter<br />

Project Development Schedule<br />

Executive Summary<br />

Existing TASSS Site and Building Analysis<br />

1. Site Statistics<br />

2. Heritage<br />

3. Zoning<br />

4. Construction History<br />

5. Existing Asbestos Deficiencies<br />

6. Existing Accessibility Deficiencies<br />

7. Existing Fire Protection Deficiencies<br />

8. Other Existing Building Code Related<br />

Deficiencies<br />

9. Existing Building Envelope Assessment<br />

10. Existing Exterior Building Finishes Assessment<br />

11. Existing Mechanical Summary<br />

12. Existing Electrical Summary<br />

13. Existing Structural Summary<br />

Existing Education Centre Analysis<br />

1. Site Analysis<br />

2. Equipment Reuse<br />

Proposed TASSS Re-Purposing<br />

1. Vision Statement<br />

2. Project Opportunities and Challenges<br />

a. Asbestos Abatement<br />

b. Building Accessibility<br />

c. Exterior Envelope<br />

d. Existing Site<br />

3. Approvals and Zoning Requirements<br />

a. Parking<br />

b. Accessibility<br />

c. Site Plan Approval<br />

d. Committee of Adjustments<br />

e. Building Permit<br />

4. Conclusions<br />

Recommended Schematic Design<br />

1. KPRDSB Education Centre and Specialized <strong>School</strong> Project<br />

Overview<br />

a. Deficiencies<br />

b. New amenities<br />

c. Business Case<br />

d. Capital Budget Options<br />

2. Redevelopment and Design Approach<br />

a. Site Analysis and Design Rationale<br />

b. Architectural Analysis and Design Rationale<br />

c. Mechanical & Electrical Analysis<br />

(Summary by Jain, based on M&E Report)<br />

d. Structural Analysis (Summary by<br />

halsall, based on Structural Report)<br />

e. Code Analysis (Summary by<br />

larden-Muniak, based on Code Report)<br />

APPENDIX<br />

A. Architectural Drawings<br />

Existing TASSS Building:<br />

site Plan<br />

Ground Floor Plan<br />

second Floor Plan<br />

third Floor Plan<br />

basement Plan<br />

Existing KPRDSB Education Centre<br />

First floor plan<br />

Second floor plan<br />

basement plan<br />

space-Planning Adjacencies<br />

Summary of Schematic Options Investigated<br />

site Plan Option 1<br />

site Plan Option 2<br />

Proposed TASSS Re-purposing:<br />

site Plan<br />

Ground Floor Plan<br />

second Floor Plan<br />

third Floor Plan<br />

basement Plan<br />

Open Office Concept Option 1<br />

Open Office Concept Option 2<br />

building Elevations 1<br />

building Elevations 2<br />

Vignettes<br />

B. Photographs<br />

existing Education Centre Interior Images<br />

existing TASSS Exterior Images<br />

existing TASSS Interior Images<br />

existing EC Shelving<br />

existing EC Transformer<br />

existing EC IT Equipment<br />

C. Structural Report<br />

D. Mechanical & Electrical Report<br />

E. Code Report<br />

F. Cost Report<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | 3


Recommendation letter<br />

4 | ZAS ARCHITECTS INC.


September 16, 2011<br />

<strong>Kawartha</strong> <strong>Pine</strong> <strong>Ridge</strong> <strong>District</strong> <strong>School</strong> <strong>Board</strong><br />

1994 Fisher Drive<br />

Peterborough, Ontario<br />

K9J 7A1<br />

Attention:<br />

Norman J. Breitner<br />

Manager of Planning Services<br />

Re: Thomas A. Stewart Secondary <strong>School</strong> Repurposing<br />

Dear Norman,<br />

In August 2011, ZAS was commissioned to complete a feasibility study for the repurposing of the Thomas A.<br />

Stewart Secondary <strong>School</strong>. Since that time facility review and analysis has proceeded with consultation from our<br />

consultant team, and the KPRDSB working group members. Our firm wishes to acknowledge the participation,<br />

efforts and contribution of all the team members as follows:<br />

KPRDSB Working Group Members:<br />

Jeff Berry<br />

Norman J. Breitner<br />

Mark Galonski<br />

rusty Hick<br />

John Lawrence<br />

doug Wilson<br />

Consultant Team<br />

structural Engineers:<br />

Mechanical & Electrical Engineers:<br />

Code Consultant:<br />

Cost Consultant:<br />

Mr. Bryan Gaines, Halsall Associates<br />

Mr. Dinesh Jain, Jain & Associates<br />

Mr. Anish Jain, Jain & Associates<br />

Mr. Hakan Nilsson, Larden Muniak Consulting<br />

Mr. Tim Moore, A.W. Hooker<br />

The detailed research and analysis in combination with the consultants and working group have resulted in a<br />

concept design that extends the life of the facility, corrects any current deficiencies and introduces opportunities for<br />

new amenities. We trust the information and concepts presented in the study will assist the board in their decisions<br />

regarding the re-purposing of the Thomas A. Stewart Secondary <strong>School</strong>.<br />

Sincerely,<br />

ZAS Architects Inc.<br />

Marek Zawadzki B.Arch., TSA, AAIA, OAA, MRAIC<br />

Senior Principal<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | 5


Executive Summary<br />

Overview<br />

Thomas A. Stewart Secondary <strong>School</strong> is located at 1009 Armour Road in Peterborough, Ontario.<br />

The school, designed by Craig Zeidler & Strong Architects, was originally built in 1967-1968. The<br />

building is sited on 29.2 acres with frontage on Armour Road and the Otonabee River. The school<br />

contains a gross area of approximately 219,328 sq.ft. (20,376 sm), including a full-size gymnasium<br />

and a 740-seat auditorium. It was originally designed for an occupant capacity of 2,048 staff<br />

and students, with 64 classrooms containing 32 people each. A June 23, 2011 report from the<br />

Accommodation Review Committee recommended that the <strong>Kawartha</strong> <strong>Pine</strong> <strong>Ridge</strong> <strong>District</strong> <strong>School</strong><br />

<strong>Board</strong> consolidate its four secondary schools into three, and that TASSS be closed as a secondary<br />

school and re-purposed as a new Education Centre.<br />

6 | ZAS ARCHITECTS INC.


Purpose<br />

The purpose of this feasibility study is to allow the <strong>Kawartha</strong> <strong>Pine</strong> <strong>Ridge</strong> <strong>District</strong> <strong>School</strong> <strong>Board</strong> to evaluate the<br />

existing conditions of the Thomas A. Stewart Secondary <strong>School</strong> and provide a proposal to extend the life of the<br />

structure by re-purposing it as a multi-use building containing an Education Centre, a Specialized <strong>School</strong> and<br />

Community Use Facility, as per the ‘Vision Statement’ outlined in the KPRDSB Request for Tender (PUR11-048).<br />

Building Lifecycle<br />

Due to the age of the facility, many basic building issues must be rectified in order to ensure compliance with<br />

current codes and standards for a modern facility. In addition, improvements are required to the site amenities<br />

and parking lot to meet City of Peterborough zoning standards.<br />

Deficiencies<br />

While the current school facility is functioning as intended, many areas do not meet modern building code,<br />

security, accessibility and health & safety requirements. The following deficiencies need to be addressed if the life<br />

of the building is to be extended:<br />

1. Asbestos containing materials are present throughout the school building. Any proposed re-purposing<br />

requires asbestos assessment and abatement.<br />

2. The school building does not meet modern accessibility standards. Any proposed re-purposing will require the<br />

building to be in compliance with the requirements of the 2006 Ontario Building Code and the guidelines set<br />

forth by the City of Peterborough Accessibility Advisory Committee.<br />

3. As per the current Ontario Building Code, any new construction is required to be sprinklered and any repurposing<br />

of the existing building would require the installation of a standpipe system.<br />

4. The existing paved areas of the Armour Road site do not provide sufficient parking for the proposed repurposing.<br />

The paved area of the site will need to be re-configured and extended to accommodate current<br />

City of Peterborough Zoning parking and loading requirements.<br />

New Amenities<br />

Due the building’s size and its proximity to the Otonabee River, the Armour Road site provides unique<br />

opportunities for Specialized <strong>School</strong> curriculums and Community Use partnerships in conjunction with the<br />

Education Centre use. Site alterations and a small building addition would allow the major use areas to coexist<br />

while addressing the existing accessibility and parking deficiencies. Asbestos and fire-protection deficiencies will<br />

be a required part of any re-purposing proposal.<br />

After completing the consultation process with the KPRDSB working group it is evident that this facility requires<br />

major upgrading in order to address its existing deficiencies and meet the new, proposed program demands.<br />

The concept plans developed for this study address the deficiencies, fulfill the new program requirements and<br />

illustrate the opportunities and challenges involved in the proposed re-purposing of the Thomas A. Stewart<br />

Secondary <strong>School</strong>.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | 7


Existing Thomas A. Stewart<br />

Secondary <strong>School</strong> (TASSS)<br />

Site and Building Analysis<br />

1. Site Statistics<br />

Address:<br />

1009 Armour Road, Peterborough<br />

Site Area: 29.2 Acres (118,167 sq.m.)<br />

Paved Area (excludes tennis courts): 12,400 sq.m.<br />

Building Footprint Area: 10,415 sq.m.<br />

Parking: 208 parking spaces<br />

Loading: 1 loading space<br />

2. Heritage<br />

As of the date of this report, TASSS is not listed on the Ontario Heritage Properties Database.<br />

8 | ZAS ARCHITECTS INC.


3. Zoning<br />

The building portion of the site that is the subject of this<br />

study is currently zoned PS.2 (Public Service Zone),<br />

permitting a “public service establishment use”. The<br />

City of Peterborough Planning Department has verbally<br />

confirmed that both the relocated KPRDSB Education<br />

Centre and the Specialized <strong>School</strong> would be permitted<br />

uses of the current zoning.<br />

There is no existing Site Plan Agreement for the site.<br />

A Site Plan Approval would be required under the<br />

following conditions:<br />

• A building addition with a footprint greater than 100<br />

square meters<br />

• Significant Parking Footprint Changes<br />

• Changes to Site Storm Water Management<br />

While the existing secondary school use is permitted<br />

on the site, the current parking configuration does not<br />

satisfy the current Peterborough Zoning requirements<br />

for this use.<br />

The site is located in Peterborough Parking Area 3,<br />

the designation with the most demanding parking<br />

requirements. Under current Peterborough Zoning,<br />

tasss would require 231 parking spaces (assuming 64<br />

classrooms and a maximum capacity of 2,048 students)<br />

– currently the site contains only 208 spaces.<br />

4. Building Statistics<br />

Height:<br />

Ground Floor GFA:<br />

Second Floor GFA:<br />

Third Floor GFA:<br />

Basement GFA:<br />

Total GFA:<br />

3 Storeys<br />

10,415 sq.m.<br />

8,470 sq.m.<br />

2,175 sq.m.<br />

680 sq.m.<br />

21,740 sq.m.<br />

Use: Secondary <strong>School</strong> with 32 classrooms and<br />

designed for a maximum occupancy of 2,048 (at 32<br />

persons per classroom).<br />

Gymnasium Area:<br />

Auditorium Area:<br />

5. Construction History<br />

1,125 sq.m.<br />

560 sq.m. (approx.<br />

740 seats)<br />

The school was constructed in 1967-1968 and opened<br />

in 1968. It has since undergone a number of interior<br />

alterations and building system upgrades. Some of<br />

these include:<br />

• 1992 Boiler and Chiller Replacement<br />

• 1994 Fire Alarm upgrade<br />

• 1998 Partial Asbestos Abatement<br />

• 2006 Window Replacement<br />

6. Existing Asbestos Deficiencies<br />

Asbestos has been confirmed to be present throughout<br />

the building, contained in building materials including<br />

sprayed fireproofing, pipe and duct insulation, acoustic<br />

ceiling tiles, drywall compound, asbestos cement<br />

products and vinyl floor tile.<br />

As per the June 2011 Asbestos Assessment report<br />

prepared by Pinchin Environmental Ltd.:<br />

“… an Asbestos Management Program is required<br />

to comply with O. Reg. 278/05. The following<br />

are components of a comprehensive Asbestos<br />

Management Program:<br />

1. An Asbestos Building Materials Assessment. Report<br />

to be kept on site and updated once every 12<br />

month period or if the information changes.<br />

2. Notify workers, staff, and prospective contractors/<br />

constructors of information regarding asbestoscontaining<br />

materials (as per this report). An<br />

employer whose workers work in a building of<br />

which the employer is not the owner shall advise<br />

the owner if workers discover material that may be<br />

asbestos-containing material in the building.<br />

3. Notify any other person who is an occupier of the<br />

building in writing of any information regarding the<br />

presence of asbestos in the area occupied by the<br />

person.<br />

4. Prepare written asbestos work practices.<br />

5. Repair or remove damaged ACM where it may<br />

be disturbed and become airborne (see Specific<br />

Recommendations).<br />

6. Provide workers who may disturb friable ACM with<br />

training on the hazards of asbestos, the use, care<br />

and disposal of protective equipment and clothing<br />

to be used and worn when doing the work, personal<br />

hygiene to be observed when doing the work, the<br />

measures and procedures prescribed by Regulation<br />

278/05.<br />

7. Submit Asbestos Work Records to the Ministry of<br />

Labour for workers performing work using Type<br />

2 or 3 procedures, on an annual basis, and upon<br />

termination of the worker.<br />

8. Allocate internal responsibilities, standardized forms,<br />

inspection and air monitoring requirements, etc.”<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | 9


Asbestos Assessment, <strong>Kawartha</strong> <strong>Pine</strong> <strong>Ridge</strong> <strong>District</strong><br />

<strong>School</strong> <strong>Board</strong> Thomas A. Stewart Secondary<br />

<strong>School</strong>, 1009 Armour Road North Peterborough,<br />

Ontario. June 28, 2011 prepared by Pinchin<br />

Environmental Ltd. for Leah Rout, <strong>Kawartha</strong> <strong>Pine</strong><br />

<strong>Ridge</strong> <strong>District</strong> <strong>School</strong> <strong>Board</strong> (Pinchin File 59723)<br />

Additionally, Pinchin’s report requires that a<br />

reassessment of the asbestos-containing materials<br />

be performed prior to April 2012, in order to remain in<br />

compliance.<br />

Pinchin’s report also make clear that in the event of<br />

any building renovation or demolition, a Designated<br />

Substances assessment as per Section 30 of the<br />

Occupational Health and Safety Act must be performed<br />

(Pinchin, Asbestos Assessment, June 2011, page 15.).<br />

Furthermore, “prior of building demolition, all ACM must<br />

be removed. Prior work brought about by renovations<br />

that may disturb a specific ACM, that specific ACM<br />

must be removed.” (Pinchin, Asbestos Assessment,<br />

June 2011, page 15.)<br />

7. Existing Accessibility Deficiencies<br />

a. Site Accessibility Deficiencies<br />

The 17 September 1999 Site Survey Prepared by Elliott<br />

and Parr Ltd. shows slopes and ramps that are, as per<br />

the requirements outlined in the current Ontario Building<br />

Code, too steep to provide an accessible path to the<br />

main building entrance at the second level.<br />

The accessible parking spaces are distributed<br />

throughout the parking lot and are often further from an<br />

accessible entrance than desirable.<br />

b. Building Accessibility Deficiencies<br />

The existing TASSS building does not meet modern<br />

accessibility standards.<br />

There are no elevators or ramps between floor levels<br />

and there are many small level-changes on the ground<br />

and second floor that are mitigated with stairs or ramps<br />

that are too steep to meet today’s standards. Some of<br />

these ramps and stairs have retrofitted lifts, but these<br />

are out-dated and undesirable solutions.<br />

Many doorways throughout the facility do not meet the<br />

clearance requirements to be considered accessible.<br />

Further information can be found in Appendix E.<br />

8. Existing Fire Protection Deficiencies<br />

Fire Department Access<br />

the existing TASSS Fire Access Route is not<br />

located within 15 m of the principal entrance.<br />

Automatic Sprinkler System<br />

While sprinklers are present in a small area of<br />

the building in an effort to meet specific code<br />

requirements, TASSS is, for the most part, nonsprinklered.<br />

Additionally, the building does not<br />

contain a stand-pipe system.<br />

as per the current Ontario Building Code, any<br />

new construction is required to be sprinklered and<br />

any re-purposing of the existing building would<br />

require the installation of a standpipe system (refer<br />

to the Code Report prepared by Larden Muniak<br />

Consulting Inc found in Appendix E).<br />

Travel Distances<br />

Many of the exit travel-distances in the building<br />

do not meet 2006 OBC requirements for nonsprinklered<br />

buildings.<br />

9. Other Existing Building Code Related<br />

Deficiencies<br />

Please refer to the Code Report prepared by Larden<br />

Muniak Consulting, Inc. (appendix E) for further coderelated<br />

information.<br />

10. Existing Building Envelope Assessment<br />

Preliminary visual observations and report from TASSS<br />

staff indicate that the building envelope is in reasonable<br />

condition. The roof and drains appear to be functioning<br />

and no leaks have been observed. All exterior windows<br />

in the building were replaced in 2006.<br />

Based on preliminary visual observations, all building<br />

washrooms will need to be updated to meet modern<br />

accessibility requirements.<br />

10 | ZAS ARCHITECTS INC.


11. Existing Exterior Building Finishes<br />

Assessment<br />

Preliminary visual observations and report from TASSS<br />

staff indicate that the exterior building finishes are in<br />

reasonable condition.<br />

The exterior brick veneer is in good condition, suffering<br />

only from minor wear and discoloration.<br />

14. Existing Structural Summary<br />

The “Draft <strong>Feasibility</strong> <strong>Study</strong> – Thomas A. Stewart<br />

Secondary <strong>School</strong> (TASSS)” (Halsall Associates 2011)<br />

notes no outstanding structural deficiencies; however<br />

alterations and upgrades are required for any new work.<br />

Please refer to Appendix C for the full report.<br />

The exterior standing seam metal system shows no<br />

signs of rust or deterioration, but the existing paint<br />

on the system is peeling in several locations. Please<br />

refer to existing building photographs (Appendix B) for<br />

further information.<br />

12. Existing Mechanical Summary<br />

As noted in “<strong>Kawartha</strong> <strong>Pine</strong> <strong>Ridge</strong> DSB Head Office<br />

Relocation Mechanical & Electrical Design Report”<br />

(Jain & Associates Ltd. 2011) the “existing mechanical<br />

system is generally in good condition because most<br />

of the major equipment and plumbing fixtures were<br />

replaced in 2006.” However, the following components<br />

are recommended for replacement due to their age:<br />

• Domestic hot water storage tank<br />

• Domestic hot water piping<br />

• Hot water and Chilled water piping<br />

Please refer to Appendix D for the full report.<br />

13. Existing Electrical Summary<br />

As noted in “<strong>Kawartha</strong> <strong>Pine</strong> <strong>Ridge</strong> DSB Head Office<br />

Relocation Mechanical & Electrical Design Report” (Jain<br />

& Associates Ltd. 2011) the “existing power distribution<br />

system is adequate to serve the proposed use of the<br />

building. Receptacles will need to be relocated/added<br />

to suit proposed usage”.<br />

Please refer to Appendix D for the full report.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | 11


12 | ZAS ARCHITECTS INC.


Existing Education<br />

Centre Analysis<br />

1. Site Analysis<br />

Site Area:<br />

6.539 acres<br />

Existing Parking Spaces: 306 (4 accessible spaces)<br />

2. Architectural Analysis<br />

Please refer to Appendix A.<br />

3. Equipment Reuse<br />

The <strong>School</strong> <strong>Board</strong> intends to reuse the following<br />

equipment from their existing facilities:<br />

• Rolling storage shelf units and associated floormounting<br />

system.<br />

• Mainframe computer server and associated A/C unit<br />

and fire suppression system. (2005 purchase)<br />

• Diesel back-up electrical generator. (2010 purchase)<br />

Please refer to Appendix B for further information.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | 13


Proposed TASSS<br />

Re-Purposing<br />

1. Vision Statement<br />

This study intends to explore the feasibility of re-purposing the existing<br />

Thomas A. Stewart Secondary <strong>School</strong> Building as a new Education<br />

Centre and Specialized <strong>School</strong> and to examine the potential for new and<br />

expanded community use partnerships of the re-purposed building. This<br />

would allow the <strong>Board</strong> to retain its unique riverside school site while providing<br />

new opportunities for emerging community partnerships.<br />

14 | ZAS ARCHITECTS INC.


The three components comprising the modern multiuse<br />

facility proposed in this study are:<br />

• The existing KPRDSB education Centre, re-located<br />

from its existing site into the south-west of the<br />

tasss building maintaining as many existing adjacencies<br />

as possible.<br />

• A specialized school focused on environmental<br />

science. As the school is currently unplanned we<br />

have designed for both elementary and secondary<br />

students.<br />

• Centralized Community Use Auditorium and Gymnasiums.<br />

2. Project Opportunities and Challenges<br />

a. Asbestos Abatement<br />

As per the June 2011 Asbestos Assessment report<br />

prepared by Pinchin Environmental Ltd., “work brought<br />

about by renovations that may disturb a specific ACM,<br />

that specific ACM must be removed.” (Pinchin, Asbestos<br />

Assessment, June 2011, page 15.)<br />

Due to the asbestos containing materials present<br />

throughout the building, the proposed re-purposing of<br />

tasss will, at a minimum, require a Designated Substances<br />

assessment as required by Section 30 of the<br />

Occupational Health and Safety Act.<br />

Pinchin’s report makes clear that even minimal renovation<br />

activities (i.e. installation of new network cabling<br />

above ceilings) will require assessment and removal of<br />

asbestos (fallen asbestos-containing fireproofing present<br />

on top of ceiling tiles, etc.) using Type 2 or Type 3<br />

procedures.<br />

Refer to Section 4.5 of Pinchin’s report for their Long<br />

Term Recommendations regarding areas of specific<br />

concern at TASSS and an outline of the abatement<br />

procedures required.<br />

The scope of the renovations required for the re-purposing<br />

of the TASSS building into an Education Centre,<br />

Community Use Facility and Specialized <strong>School</strong> provide<br />

KPRDSB with an opportunity to perform a thorough<br />

assessment and asbestos abatement during the period<br />

that the building is closed and unoccupied. While there<br />

is cost associated with immediate large-scale abatement,<br />

in terms of long-term budgeting, it is far more<br />

economical than performing piecemeal abatements in<br />

the future.<br />

b. Building Accessibility<br />

The existing TASSS building and site do not meet<br />

modern accessibility standards. The following<br />

accessibility deficiencies are considered high-priority<br />

and should be part of any renovation or re-purposing<br />

project:<br />

• Accessible entrance(s) in close proximity to<br />

designated handicapped parking<br />

• Accessible doors along accessible paths of travel<br />

• Accessible paths of travel navigating intra-floor level<br />

changes<br />

• Accessible elevators navigating between the three<br />

building levels<br />

• Alterations to washrooms to meet current<br />

accessibility standards<br />

Any accessibility alterations should be in compliance<br />

with both the 2006 Ontario Building Code, and the<br />

City of Peterborough Accessibility Advisory Committee<br />

requirements. For further information, refer to the<br />

City of Peterborough Accessibility Guidelines dated<br />

September 2002.<br />

c. Exterior Envelope<br />

The existing standing-seam metal cladding has peeling<br />

paint and will need to be properly scraped, cleaned and<br />

re-painted.<br />

d. Existing Site<br />

The existing TASSS site is currently provides 208<br />

parking spaces. This will not be sufficient for any<br />

re-purposing which includes an Education Centre<br />

component.<br />

The existing paving will need to be re-striped and<br />

extended to accommodate the parking requirements<br />

of the proposed building re-purposing. This will likely<br />

alter the existing storm water management conditions<br />

(surface run-offs, etc.) and a new storm water<br />

management approach will need to be implemented.<br />

3. Parking Requirements<br />

The Armour Road site is located in Peterborough<br />

Parking Area 3 and contains 208 existing parking<br />

spaces and 1 loading area. Additional Parking will be<br />

required if the school is re-purposed to include the<br />

Education Centre component.<br />

Re-purposed Parking Requirements per<br />

Peterborough Zoning:<br />

Specialized <strong>School</strong>:<br />

60 spaces required (Assuming 20 classrooms and a<br />

maximum capacity of 400 students)<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | 15


Peterborough Zoning Requires 2 spaces per classroom<br />

+ 1 space per 20 students<br />

Education Centre (office use):<br />

306 spaces required to match existing KPRDSB<br />

Education Centre parking provisions.<br />

369 spaces required as per Peterborough Zoning.<br />

(Assuming 10,320 sq.m. office floor area)<br />

Peterborough Zoning requires 1 space per 28<br />

square meters office floor area.<br />

Auditorium and Gymnasium:<br />

0 additional spaces required if considered as accessory<br />

uses to the <strong>School</strong>.<br />

437 additional spaces required if considered community<br />

assembly spaces. (Assuming 1,685 sq.m.<br />

square meters assembly floor area and 15 staff)<br />

Peterborough Zoning requires 1 space per staff and<br />

1 space per 4 square meters assembly floor area.<br />

Parking Scenario 1:<br />

Specialized <strong>School</strong>:<br />

Education Centre<br />

parking per<br />

Peterborough Zoning:<br />

Community Assembly<br />

Spaces: 437 spaces<br />

Total Parking Required:<br />

Accessible Parking<br />

Required:<br />

Parking Scenario 2:<br />

Specialized <strong>School</strong><br />

with Gymnasium<br />

and Auditorium as<br />

accessory uses:<br />

Education Centre<br />

(with parking to match<br />

existing Education Centre):<br />

Total Parking Required:<br />

Accessible Parking<br />

Required:<br />

60 spaces<br />

369 spaces<br />

866 spaces<br />

18 spaces<br />

60 spaces<br />

306 spaces<br />

366 spaces<br />

9 spaces<br />

Both scenarios require only 1 loading area per<br />

Peterborough Zoning.<br />

The existing paved area on the site is unable to<br />

achieve the parking requirements outlined above (for<br />

either Parking Scenario 1 or 2). As such, if the board<br />

decides not to extend the area of paving, a variance<br />

from the Committee of Adjustments will be required<br />

for any re-purposed use of the building. Please note<br />

that these numbers are an estimate – full parking<br />

requirements will require detailed consultation with city<br />

zoning & parking staff.<br />

The existing paved area on the site can be re-striped<br />

per current Peterborough Zoning standards to include<br />

283 spaces and a bus-loop with only minor alterations<br />

(Refer to Appendix A – Site Plan Option 1).<br />

If the existing tennis courts are removed and deadend<br />

parking is extended to this area it is possible to<br />

achieve 359 spaces and a bus-loop (Refer to Appendix<br />

A – Site Plan Option 2). This alteration could<br />

trigger the need for a Site Plan Approval and would<br />

not conform to Peterborough Zoning requirements in<br />

either parking scenario.<br />

If the east side of the site adjacent to Armour Road,<br />

including the existing tennis courts, is repaved and<br />

restriped to construct a new two-way parking lot to<br />

current Peterborough Zoning standards featuring:<br />

• Minimized dead-end parking (only in loading area)<br />

• Re-located secure loading and garbage area<br />

• Bus loop adjacent to future school<br />

• Accessible paths to all building entrances<br />

• 486 parking spaces<br />

4. Approval and Zoning Requirements<br />

As the TASSS site has no existing Site Plan Agreement<br />

with the City of Peterborough, any project proposing<br />

”significant” changes to the existing TASSS building or<br />

the existing site parking footprint would require a Site<br />

Plan Agreement. Any re-purposed use scenario would<br />

require changes to the site parking footprint. Therefore,<br />

the Site Plan Control (SPC) process will be part of any<br />

site redevelopment.<br />

A minimum of three months should be allowed for the<br />

SPC and the following drawings and reports (non-inclusive)<br />

would be prepared for the initial submission:<br />

• Stormwater Management Report<br />

• Site Parking <strong>Study</strong><br />

• Site Plan Control Forms<br />

• Site Survey<br />

• Building Code Classification and Fire Protection<br />

Requirements of all existing and proposed buildings<br />

• Statistical Summary of development parameters<br />

• Proposed Site plan<br />

• Proposed Floor Plans<br />

• Proposed Elevations<br />

16 | ZAS ARCHITECTS INC.


The Otonabee Region Conservation Authority (ORCA)<br />

is involved in the SPC process and will review the<br />

drawings to determine if an additional permit will be<br />

required. An ORCA permit is likely to be required if there<br />

are any changes proposed to the part of the site zoned<br />

OS or any changes to the site stormwater management<br />

that affect the Otonabee River floodplain.<br />

If any proposed re-purposing project is unable to meet<br />

City of Peterborough Parking requirements a minor variance<br />

will be required before a building permit is issued.<br />

The Peterborough Committee of Adjustments (CoA) is<br />

the authority responsible for granting minor variances.<br />

The CoA meets bi-monthly and any minor variance<br />

ruling will be followed by a 20-day appeal period, so a<br />

minimum of two months should be allowed. The CoA<br />

process can run parallel with the SPC process and<br />

would require the following drawings and reports (noninclusive):<br />

• Stormwater Management Report<br />

• Site Parking <strong>Study</strong><br />

• Site Survey<br />

• Statistical Summary of development parameters<br />

• Proposed Site plan<br />

• Proposed Floor Plans<br />

• Proposed Elevations<br />

Once a Site Plan Agreement has been reached, a minor<br />

variance granted and its associated appeals period<br />

lapsed a building permit can be obtained. A minimum<br />

of one month should be allowed for the building permit<br />

review process.<br />

If ORCA requires an additional permit, an additional<br />

minimum three weeks should be allowed for prior to the<br />

building permit application.<br />

5. Conclusions and Recommendations<br />

The potential re-purposing of the existing Thomas<br />

A. Steward Secondary <strong>School</strong> building as the<br />

new <strong>Kawartha</strong> <strong>Pine</strong> <strong>Ridge</strong> <strong>District</strong> <strong>School</strong> <strong>Board</strong><br />

Education Centre and Specialized school provides<br />

the school board with a unique opportunity to create<br />

a new, modern office space for staff, an exceptional<br />

environmental educational facility on a distinctive<br />

riverside site for students, and expanded community<br />

use partnerships for area residents.<br />

Remedial site work required by the City of<br />

Peterborough Zoning requirements appears easily<br />

achievable through the Site Plan Control process and a<br />

Minor Variance application (primarily for parking relief).<br />

Clearly, issues related to the age of the building need<br />

to be addressed – foremost among these is dealing<br />

with the extent of asbestos and asbestos containing<br />

materials contained within the building. While often<br />

convenient, a piecemeal asbestos abatement<br />

program is simply not cost effective, and cannot be<br />

recommended.<br />

Although the extent of a thorough asbestos abatement<br />

is likely to be destructive in nature (requiring the<br />

removal of ceilings, partition walls, etc.), it also presents<br />

an opportune time to install a new sprinkler system<br />

throughout the TASSS building – thereby resolving<br />

travel-distance and exiting deficiencies in several<br />

locations.<br />

Finally, in order to bring TASSS up to modern building<br />

code standards, barrier-free and accessibility provisions<br />

must be provided where required (including elevators,<br />

ramps and redesigned washrooms).<br />

These aforementioned efforts are needed to produce<br />

a ‘clean state’ (in compliance with the current Ontario<br />

Building Code) from which can be developed any<br />

number of building uses. It should be noted that in the<br />

event the TASSS re-purposing does not move forward,<br />

any investment to correct non-compliance and indoor<br />

environmental quality issues will still serve to increase the<br />

value of the property and can be expected to be returned<br />

in the event that sale is considered in the future.<br />

We feel confident that the Order of Magnitude summary<br />

realistically reflects the probable costs to achieve the<br />

TASSS repurposing. In our professional opinion, it is<br />

unlikely that the full programmatic requirements could<br />

be achieved for less.<br />

In keeping with the KPRDSB re-purposed Thomas<br />

A. Stewart Secondary <strong>School</strong> ‘Vision Statement’, the<br />

proposed scheme developed by the consultant team<br />

acknowledges and addresses these challenges in a<br />

cost-effective manner, while concurrently creating<br />

a modernized and much-improved environment for<br />

all users of the facility. We therefore recommend<br />

proceeding with the development plans contained in<br />

this study.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | 17


Recommended<br />

Schematic Design<br />

1. Redevelopment and Design Approach<br />

a. Site Analysis and Design Rationale<br />

Site Statistics:<br />

The TASSS site features many amenities – its riverside<br />

location, extensive open space and sports fields, but<br />

lacks modern parking, accessible paths to the TASSS<br />

building and an identifiable street presence. The “front<br />

door” of the building is hidden behind mechanical<br />

equipment and a loading dock.<br />

Address:<br />

Site Area:<br />

Paved Area:<br />

Building<br />

Footprint Area:<br />

Parking:<br />

Loading:<br />

1009 Armour Road, Peterborough<br />

29.2 Acres (118,167 sq.m.)<br />

17,500 sq.m.<br />

10,415 sq.m.<br />

479 parking spaces<br />

1 loading space<br />

Re-purposing the TASSS building requires additional<br />

parking for the new uses and presents an opportunity<br />

to address outstanding site deficiencies.<br />

Loading Dock Relocation:<br />

Proposed Education Centre uses require secure loading<br />

and parking space for staff, couriers and deliveries. A<br />

controlled-access loading/maintenance/delivery area is<br />

proposed south of the existing greenhouse. This allows<br />

18 | ZAS ARCHITECTS INC.


for all current Education Centre uses to be contained<br />

in one controllable space that is not blocking the “front<br />

door” of the building.<br />

New Signage:<br />

New pylon signs are proposed at the main driveway<br />

entrance points from Armour Road. These will enhance<br />

the buildings street identity and allow passing cars to<br />

easily locate the site entrances. Signage on the TASSS<br />

building and the proposed canopy will help direct site<br />

traffic to appropriate building entrances.<br />

Accessible Parking and Paths:<br />

Proposed changes to the current parking layout<br />

maximize site parking and preserve desirable green<br />

space. Additional parking in the current tennis court<br />

location is at a lower grade and requires an accessible<br />

path to the building entrance. A series of ramps are<br />

proposed and will present an opportunity for planters<br />

that will serve to enhance the TASSS street image.<br />

A new drop-off is proposed in the current loading area<br />

to facilitate accessible access to the new building<br />

entrance in the same area.<br />

b. Architectural Analysis and Design Rationale<br />

In its current condition, the Thomas A. Steward<br />

Secondary <strong>School</strong> building lacks any real street<br />

address. This is due to a combination of factors<br />

including the deep site setback, lack of signage, lack<br />

of distinguishing architectural features and locations of<br />

large mechanical and electrical units near the building.<br />

Additionally, the location of the loading dock area – and<br />

its proximity to the stair leading up to the second floor<br />

entrance courtyard – has been less than ideal.<br />

Repurposing of the existing TASSS building into<br />

an Education Centre, Community Use Facility,<br />

and Specialized <strong>School</strong> provides the KPRDSB the<br />

opportunity to architecturally address the issues<br />

outlined above, and to refine and clarify entry into the<br />

building. The proposed scheme attempts to provide<br />

distinct and identifiable entrances to each of the three<br />

proposed building uses.<br />

The entry sequence to the Education Centre and<br />

Community Use Facility entrances are defined by the<br />

addition of large entrance canopy which extends from<br />

the former loading dock area to the second floor entry<br />

courtyard.<br />

The former loading dock area becomes the new<br />

barrier-free entrance to the Education Centre, where<br />

an elevator carries guests up to the redesigned main<br />

entrance lobby.<br />

Height:<br />

Ground Floor GFA:<br />

Second Floor GFA:<br />

Third Floor GFA:<br />

Basement GFA:<br />

Total GFA:<br />

3 Storeys<br />

10,480 sq.m.<br />

8,645 sq.m.<br />

2,175 sq.m.<br />

680 sq.m.<br />

21,740 sq.m.<br />

As much as possible, the proposed layout for the<br />

Education Centre offices follows the Vision Statement<br />

outlined in the Request for Tender (PUR11-048),<br />

the drawings provided in Appendix 2 of Request for<br />

Tender, and the Adjacency Priorities Matrix filled out by<br />

KPRDSB staff.<br />

Education Centre Use:<br />

10,320 sq.m.<br />

Open Office Concept:<br />

Specialized <strong>School</strong> Use:<br />

Secondary <strong>School</strong> with 20 classrooms and designed<br />

for a maximum occupancy of 400 (at 20 persons per<br />

classroom).<br />

Community Use:<br />

Gymnasium Area:<br />

Auditorium Area:<br />

1,125 sq.m.<br />

560 sq.m.<br />

(approx. 740 seats)<br />

The internal ‘open office’ design implements a blend<br />

of private offices, workstations and support spaces.<br />

This arrangement provides an effective open plan<br />

landscape with all necessary tools needed to support<br />

a productive environment and accommodates changes<br />

while maintaining an organized and efficient office<br />

environment.<br />

Enclosed private offices strategically located away from<br />

the windows have fully-glazed, floor-to-ceiling fronts,<br />

which allow for the use of “borrowed light” and ensures<br />

a transparent and collaborative work style. For privacy<br />

semi-transluscent film application on glazing can be<br />

applied as required for individual offices.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | 19


An open 37 ft. deep workspace allows maximum<br />

flexibility and access to natural light. All filing cabinets,<br />

screens, shelving and storage elements are kept low to<br />

ensure natural light permeates throughout the space.<br />

Located along main corridors are low filing or storage<br />

cabinets with integrated tops. This is a designated<br />

area for equipment (printers, copiers, etc.) as well as a<br />

shared work counter. Additional low filing cabinets can<br />

be located along the exterior wall.<br />

The following workspace types have been used:<br />

Private Office<br />

Assistant’s Workstation<br />

Standard Workstation<br />

Large Workstation<br />

10.5 ft. x 11.5 ft.<br />

8 ft. x 8 ft.<br />

6 ft. x 8 ft.<br />

12 ft. x 8 ft.<br />

Each workstation type easy converts from large to<br />

small and vice versa – two regular workstations equal<br />

one large workstation, and the components used in<br />

both workstations are interchangeable. Standardized<br />

workstations can also be easily reconfigured to<br />

accommodate various functions and work styles such<br />

as ‘teaming’ or ‘heads-down’.<br />

Perpendicular to the windows, ‘spines’ provide wire<br />

management and the opportunity to hang overhead<br />

storage without blocking natural light.<br />

Each team cluster is equipped with a mobile table to<br />

encourage impromptu team meetings or to receive<br />

visitors.<br />

Supplementary storage or work areas can be provided<br />

by the small guest waiting area located at each entry<br />

point to the space. The larger area near the elevator is<br />

outfitted with a coat closet. These areas can also be<br />

used as casual meeting spaces.<br />

20 | ZAS ARCHITECTS INC.


Project Development<br />

Schedule<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | 21


PROJECT<br />

Development Schedule<br />

KPRDSB <strong>Feasibility</strong> <strong>Study</strong> - Development Schedule<br />

2011<br />

2012<br />

2013<br />

J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D<br />

Feasiblilty <strong>Study</strong><br />

2<br />

Site Preparation<br />

1 2 1 1 1 1<br />

Site Works<br />

1 2 1 1 1 3<br />

Landscaping<br />

1 2 2 1 1 2<br />

Hazardous Materials Assessment<br />

1<br />

Hazardous Materials Abatement<br />

2 1 1<br />

Demolition<br />

1 1 0.5 1.5 0.5 3 1 1 1 3<br />

Education Centre<br />

1 1 0.5 1.5 0.5 3 1 0.5 1 10 2 2<br />

Community Use<br />

1 1 0.5 1.5 0.5 3 1 0.5 10.5 1 1<br />

Specialized <strong>School</strong><br />

1 1 0.5 1.5 0.5 3 1 0.5 9.5 1 1<br />

Approvals<br />

Building Permit<br />

4<br />

SPA<br />

ORCA<br />

Committee of Adjustment<br />

Stipulated Contract<br />

Phases of Work<br />

<strong>Feasibility</strong> <strong>Study</strong><br />

Visioning / Program<br />

Design<br />

Design Development<br />

Construction Documents<br />

Tender Period<br />

Tender Award<br />

Construction<br />

Commissioning<br />

Migration<br />

Responses for Approval<br />

Approvals<br />

Planning Approvals<br />

Related Negotiations / Appeals<br />

Building Permit<br />

Building Permit<br />

Site Plan Agreement<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | 22


Appendix<br />

A. Architectural Drawings<br />

Existing TASSS Building:<br />

site Plan<br />

Ground Floor Plan<br />

second Floor Plan<br />

third Floor Plan<br />

basement Plan<br />

Existing KPRDSB Education Centre<br />

First floor plan<br />

Second floor plan<br />

basement plan<br />

space-Planning Adjacencies<br />

C. Structural Report<br />

D. Mechanical & Electrical ReporT<br />

E. Code Report<br />

F. Cost Report<br />

Summary of Schematic Options Investigated<br />

site Plan Option 1<br />

site Plan Option 2<br />

Proposed TASSS Re-purposing:<br />

site Plan<br />

Ground Floor Plan<br />

second Floor Plan<br />

third Floor Plan<br />

basement Plan<br />

Open Office Concept Option 1<br />

Open Office Concept Option 2<br />

building Elevations 1<br />

building Elevations 2<br />

Vignettes<br />

B. Photographs<br />

Existing TASSS Exterior Images<br />

existing TASSS Interior Images<br />

existing EC Shelving<br />

existing EC Transformer<br />

existing EC IT Equipment<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | 23


A. Architectural Drawings<br />

Existing TASSS Building:<br />

site Plan<br />

Ground Floor Plan<br />

second Floor Plan<br />

third Floor Plan<br />

basement Plan<br />

Existing KPRDSB Education Centre<br />

First floor plan<br />

Second floor plan<br />

basement plan<br />

space-Planning Adjacencies<br />

Summary of Schematic Options Investigated<br />

site Plan Option 1<br />

site Plan Option 2<br />

Proposed TASSS Re-purposing:<br />

site Plan<br />

Ground Floor Plan<br />

second Floor Plan<br />

third Floor Plan<br />

basement Plan<br />

Open Office Concept Option 1<br />

Open Office Concept Option 2<br />

building Elevations 1<br />

building Elevations 2<br />

Vignettes<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre


47'<br />

IB<br />

33'<br />

IB<br />

8'<br />

20'<br />

IB<br />

SIB WIT.<br />

(P&P)<br />

GOAL POST<br />

N85°43'10"E<br />

BACKSTOP<br />

GOAL POST<br />

SIB<br />

BACKSTOP<br />

575.74'<br />

GOAL POST<br />

GOAL POST<br />

POST & PAGE WIRE FENCE<br />

IB<br />

7'<br />

6'<br />

31'<br />

79.07'<br />

N88°40'40"E<br />

7'<br />

1'<br />

SIB WIT.<br />

(P&P)<br />

23'<br />

35'<br />

IB<br />

6'<br />

IB<br />

16'<br />

585'±<br />

IB<br />

0+70<br />

42'<br />

BENCH<br />

60'<br />

CONC.<br />

PAD<br />

81'<br />

SIB<br />

(P&P)<br />

98'<br />

108'<br />

110'<br />

CONC.<br />

PAD<br />

F<br />

SIB<br />

(E&P)<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

SIB<br />

(E&P)<br />

SIB<br />

(E&P)<br />

SSIB<br />

X<br />

X<br />

X<br />

SIB<br />

(873)<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

SIB<br />

(E&P)<br />

X<br />

X<br />

X<br />

X<br />

SIB<br />

(E&P)<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

SIB<br />

(P&P)<br />

SOUTHWEST CORNER<br />

LOT 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

TOP OF STEEL<br />

CULVERT (1.0' DIA.)<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

C L<br />

F<br />

F<br />

F<br />

C L<br />

F<br />

F<br />

GRAVEL ROAD<br />

F<br />

F<br />

SOCCER POST<br />

SOCCER POST<br />

ASPHALT<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

GOAL POST<br />

F<br />

PAD<br />

CONC.<br />

CONC.<br />

PAD<br />

N85°43'50"E<br />

GOAL POST<br />

BOTTOM OF DITCH<br />

F<br />

F<br />

F<br />

L<br />

C<br />

F<br />

DOORSILL<br />

F<br />

CONC. WALK<br />

F<br />

F<br />

F<br />

F<br />

ASPHALT<br />

F<br />

FLOOR<br />

EDGE OF TREES AND BUSHES<br />

F<br />

F<br />

F<br />

F<br />

STEPS<br />

C L<br />

F<br />

F<br />

BOTTOM OF DITCH<br />

F<br />

F<br />

CONC.<br />

WALK<br />

F<br />

FLOOR<br />

CONC.<br />

RET.<br />

WALL<br />

F<br />

ASPHALT<br />

F<br />

F<br />

LC DOORSILL<br />

F<br />

ASPHALT<br />

F<br />

SOCCER POST<br />

SOCCER POST<br />

C L<br />

DOORSILL<br />

CONC.<br />

PAD<br />

F<br />

F<br />

FLAG POLE<br />

PLAQUE<br />

F<br />

SHRUBS<br />

ASPHALT<br />

C L<br />

FLOWER<br />

BED<br />

TOP BANK<br />

ASPHALT<br />

GOAL POST<br />

GOAL POST<br />

F<br />

OIL TANK 5.DIA.<br />

SIB<br />

(1455)<br />

F<br />

F<br />

F<br />

F<br />

CONC.<br />

PAD<br />

F<br />

CONC.<br />

PAD<br />

F<br />

F<br />

F<br />

F<br />

F<br />

C L<br />

IB<br />

IB<br />

F<br />

F<br />

F<br />

ASPHALT<br />

810.34'<br />

F<br />

F<br />

F<br />

F<br />

EDGE OF TREES AND BUSHES<br />

TOP BANK<br />

SHED<br />

F<br />

F<br />

F<br />

ASPHALT<br />

IB<br />

F<br />

DECK<br />

F<br />

IB<br />

F<br />

ASPHALT<br />

F<br />

WOOD<br />

STEPS<br />

F<br />

F<br />

F<br />

F<br />

ASPHALT<br />

F<br />

F<br />

SIB<br />

(E&P)<br />

BLD.<br />

CONC.<br />

MONUMENT<br />

F<br />

F<br />

X<br />

X<br />

F<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

F<br />

F<br />

ASPHALT<br />

F<br />

F<br />

F<br />

BENCHES<br />

ASPHALT<br />

ASPHALT<br />

ASPHALT<br />

IB<br />

(P&P)<br />

SSIB<br />

F<br />

24.92'<br />

SSIB<br />

SIB<br />

(E&P)<br />

F<br />

F<br />

SIB<br />

(E&P)<br />

6'<br />

7'<br />

1'<br />

6'<br />

16'<br />

81'<br />

108'<br />

110'<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

GRAVEL ROAD<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

Based on Survey by Elliott and Parr OLS dated 7th September 1999<br />

28'<br />

48'<br />

N17°46'20"E<br />

77.98'<br />

IB<br />

18'<br />

N30°45'30"W<br />

IB<br />

AREA=0.16± Acres<br />

33'<br />

8'<br />

2+77.31<br />

22'<br />

141.46'<br />

11'<br />

IB<br />

N51°03'40"W<br />

11'<br />

HIGH WATER MARK<br />

CONCESSION 12<br />

23'<br />

GOAL POST<br />

GOAL POST<br />

18'<br />

277.31'<br />

10'<br />

BACKSTOP<br />

SIB<br />

18'<br />

N37°32'30"E<br />

275.12'<br />

"BUSH"<br />

41'<br />

7'<br />

0+07<br />

0+50'<br />

HIGH WATER MARK<br />

79.07'<br />

N88°40'40"E<br />

23'<br />

"BUSH"<br />

IB<br />

IB<br />

0+70<br />

METAL CLAD<br />

GARAGE<br />

P.I.N. 28464-0040<br />

CONC.<br />

PAD<br />

X<br />

X X X<br />

X X<br />

X X X<br />

1538.48'<br />

"BUSH"<br />

PAR<br />

"ROTARY GREENWA<br />

P.I.N. 28465-0<br />

"BUSH"<br />

N0°46'W<br />

X X<br />

X X<br />

SIB<br />

(P&P)<br />

F F<br />

N85°43'50"E<br />

5.891<br />

Existing TASSS Building<br />

810.34'<br />

Site Plan<br />

P.I.N. 28465-0061<br />

EDGE OF TREES AND BUSHES<br />

LOT 3<br />

"TRACK"<br />

Acres<br />

TOP BANK<br />

GOAL POST<br />

WOOD<br />

SCOREBOARD<br />

EDGE OF TREES AND BUSHES<br />

TOP BANK<br />

SHED<br />

BENCHMARK<br />

TOP BANK<br />

ASPHALT TRACK<br />

ASPHALT TRACK<br />

BLD.<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

LINE OF CURBS<br />

N2°29'W<br />

CH.=19.07'<br />

IB<br />

(P&P)<br />

ARC=19.07'<br />

RAD.=1959.86'<br />

ASPHALT<br />

243.95' (PLAN & MEAS.)<br />

24.92'<br />

543.95'<br />

SIB<br />

(E&P)<br />

PART 31<br />

28'<br />

48'<br />

77.98'<br />

N17°46'20"E<br />

N30°45'30"W<br />

AREA=0.16± Acres<br />

33'<br />

18'<br />

N7°31'40"E<br />

2+77.31<br />

22'<br />

141.46'<br />

11'<br />

223.97'<br />

N51°03'40"W<br />

11'<br />

X<br />

HIGH WATER MARK<br />

"BUSH"<br />

CONCESSION 12<br />

23'<br />

X<br />

BLOCK A<br />

X<br />

18'<br />

X<br />

277.31'<br />

10'<br />

OTONABEE RIVER<br />

X<br />

X<br />

P.I.N. 28464-0040<br />

18'<br />

X<br />

LOT 3<br />

AREA=6.88± Acres<br />

N37°32'30"E<br />

REGISTERED PLAN No. 12G<br />

X<br />

P.I.N. 28464-0041<br />

X<br />

X<br />

275.12'<br />

"BUSH"<br />

X<br />

41'<br />

0+07<br />

0+50'<br />

HIGH WATER MARK<br />

X<br />

HIGH WATER MARK<br />

N0°20'30"W<br />

X<br />

375.63'<br />

"BUSH"<br />

"BUSH"<br />

X<br />

P.I.N. 28464-0040<br />

N71°38'30"E<br />

X X<br />

METAL CLAD<br />

GARAGE<br />

120.00'<br />

CREEK<br />

"BUSH"<br />

X<br />

130'±<br />

BOARD FENCE<br />

HIGH WATER MARK<br />

X<br />

P.I.N. 28464-0040<br />

X<br />

"BUSH"<br />

N0°46'W<br />

PART 1<br />

"BUSH"<br />

PART 1<br />

"BUSH"<br />

738.48'<br />

N0°46'W<br />

X<br />

"BUSH"<br />

N0°46'W<br />

PLAN 45R-9209<br />

"ROTARY GREENWAY TRAIL"<br />

N0°41'10"W<br />

65.00'<br />

PART 1<br />

(ASPHALT)<br />

X<br />

POST & PAGE WIRE FENCE<br />

N44°29'50"E<br />

21.24'<br />

800.00'<br />

"ROTARY GREENWAY TRAIL"<br />

1538.48'<br />

"BUSH"<br />

P.I.N. 28465-0001<br />

POST & PAGE WIRE FENCE<br />

(ASPHALT)<br />

N0°46'W<br />

"BUSH"<br />

PLAN 45R-9209<br />

PART 1<br />

"BUSH"<br />

N0°46'W<br />

P.I.N. 28465-0001<br />

"BUSH"<br />

X X<br />

"ROTARY GREENWAY TRAIL"<br />

POST & PAGE WIRE FENCE<br />

642.90'<br />

(ASPHALT)<br />

1128.95'<br />

CHAIN LINK FENCE<br />

P.I.N. 28465-0001<br />

"BUSH"<br />

486.05'<br />

SAND<br />

VOLLEYBALL COURT<br />

"BUSH"<br />

N0°46'W<br />

318.10'<br />

GRAVEL PATH<br />

(6' WIDE)<br />

POST & PAGE WIRE FENCE<br />

ASPHALT DITCH<br />

(2' WIDE)<br />

(6' WIDE)<br />

GRAVEL PATH<br />

P.I.N. 28465-0061<br />

N72°58'50"E<br />

LOT 2<br />

LOT LINE<br />

LOT 3<br />

GARAGE<br />

METAL CLAD<br />

METAL CLAD<br />

GARAGE<br />

F F<br />

METAL CLAD<br />

GARAGE<br />

GRAVEL ROAD<br />

GRAVEL<br />

WALK<br />

PAD<br />

CONC.<br />

ASPHALT<br />

GATE<br />

X<br />

CHAIN LINK FENCE<br />

TWO STOREY<br />

BRICK<br />

SCHOOL<br />

BLOCK 28710<br />

X X<br />

STEEL FENCE<br />

PETERBOROUGH<br />

CONDOMINIUMPLANNo. 10<br />

REGISTERED PLAN No. 12G<br />

CONCESSION 12<br />

CONC. WALK<br />

LOT 3<br />

TOP OF BANK<br />

STEPS &<br />

HAND RAILS<br />

CHIMNEY<br />

RAILING<br />

GLASS<br />

GREENHOUSES<br />

CONC. RAMP & RAILING<br />

CONC. RETAINING<br />

WALLS<br />

CONC.<br />

RET.<br />

WALL<br />

"TRACK"<br />

P.I.N. 28465-0061<br />

"GRASS FIELD"<br />

AREA=20.19 Acres<br />

STEPS &<br />

RAILING<br />

GRASS<br />

STEEL FENCE<br />

LINE OF CURBS<br />

GATE<br />

"TRACK"<br />

5.891 Acres<br />

GRAVEL ROAD<br />

WINDOW WELL<br />

415 - TA Stewart SS Site Plan<br />

X<br />

X X<br />

X X X<br />

X<br />

X<br />

F F<br />

P.I.N. 28465-0060<br />

X<br />

X<br />

THREE STOREY<br />

BRICK<br />

SCHOOL<br />

X<br />

ENCLOSED<br />

HYDRO<br />

614.02' (MEAS.)<br />

ASPHALT<br />

WALK<br />

CONC.<br />

PAD<br />

STEEL RAILING<br />

ENCLOSED<br />

AIR<br />

CONDITIONING<br />

UNIT<br />

CONC. RET.<br />

WALLS<br />

CONC. RET. WALL<br />

STEEL RAILING<br />

CONC. RET. WALL<br />

P.I.N. 28465-0061<br />

X<br />

X<br />

CHAIN LINK FENCE<br />

GRAVEL ROAD<br />

CIVIC No. 1009<br />

"THOMAS A. STEWART SECONDARY SCHOOL"<br />

CONCESSION 12<br />

BLOCK 28709<br />

ASPHALT ENT.<br />

RAILING<br />

X X X X X X X<br />

RAILING<br />

PETERBOROUGH<br />

CONDOMINIUMPLANNo. 9<br />

LINE OF CURBS<br />

N24°22'30"E<br />

LINE OF CURBS<br />

CHAIN LINK FENCE<br />

129.21'<br />

X<br />

RAILING<br />

RAILING<br />

WOOD<br />

SCOREBOARD<br />

CONC. WALK<br />

N32°33'E<br />

25.18'<br />

X X X X X<br />

TOP BANK<br />

X<br />

ASPHALT<br />

X<br />

STEEL FENCE<br />

PLAN 45R10927<br />

PART 1<br />

X<br />

GRASS<br />

LINE OF CURBS<br />

LINE OF CURBS<br />

N62°51'40"W<br />

68.37'<br />

GRAVEL ROAD<br />

ASPHALT WALK<br />

X X<br />

STEEL FENCE<br />

X X<br />

X<br />

X<br />

TOP BANK<br />

STEEL FENCE<br />

X X X<br />

X<br />

LOT 4<br />

BENCHMARK<br />

GRASS<br />

BEARING REFERENCE LINE<br />

17.04'<br />

ASPHALT TRACK<br />

X<br />

N23°17'20"E<br />

CONC. WALK<br />

TOP BANK<br />

ASPHALT TRACK<br />

CL<br />

X<br />

CHAIN LINK FENCE<br />

X<br />

X<br />

ASPHALT TRACK<br />

X X X X<br />

X<br />

X<br />

LINE OF CURBS<br />

LINE OF CURBS<br />

X<br />

CURB<br />

X<br />

GATE<br />

CHAIN LINK FENCE<br />

X<br />

OTONABEE RIVER<br />

X<br />

ASPHALT TRACK<br />

CHAIN LINK FENCE<br />

CURB<br />

X<br />

CHAIN LINK FENCE<br />

X<br />

"TENNIS COURTS" "TENNIS COURTS"<br />

189.21'<br />

X<br />

CHAIN LINK FENCE<br />

PART 29<br />

LINE OF CURBS<br />

X X<br />

X<br />

SHRUBS<br />

X<br />

CENTRE LINE OF ROAD<br />

LINE OF CURBS<br />

X<br />

GRASS<br />

TOPNUT &<br />

N.E. ARM<br />

FIRE HYDRANT<br />

N2°29'W<br />

CH.=19.07'<br />

RAD.=1959.86'<br />

ARC=19.07'<br />

GRASS<br />

SHRUBS<br />

RAD.=553.11'<br />

CH.=249.32'<br />

ARC=251.48'<br />

CURB<br />

N2°45'40"W<br />

243.95' (PLAN & MEAS.)<br />

(PLAN & SET)<br />

PART 29<br />

EXPROPRIATION PLAN No. 177853<br />

N2°45'40"W<br />

N10°15'50"E<br />

543.95'<br />

LINE OF CURBS<br />

HYDRO POLE<br />

PART 31<br />

CENTRE LINE OF ROAD<br />

CURB<br />

TOPNUT<br />

FIRE HYDRANT<br />

ARMOUR ROAD<br />

CENTRE LINE OF ROAD<br />

CURB<br />

CENTRE LINE OF ROAD<br />

CURB<br />

HIGH WATER MARK<br />

N0°20'30"W<br />

SIB WIT.<br />

(P&P)<br />

375.63'<br />

IB<br />

"BUSH"<br />

X<br />

P.I.N. 28464-0040<br />

N71°38'30"E<br />

120.00'<br />

"BUSH"<br />

X<br />

130'±<br />

BOARD FENCE<br />

42'<br />

BENCH<br />

HIGH WATER MARK<br />

60'<br />

X<br />

N0°46'W<br />

SIB<br />

(P&P)<br />

98'<br />

PART 1<br />

"BUSH"<br />

"BUSH"<br />

PART 1<br />

738.48'<br />

N0°46'W<br />

CONC.<br />

PAD<br />

"BUSH"<br />

N0°46'W<br />

PLAN 45R-9209<br />

N0°41'10"W<br />

"ROTARY GREENWAY TRAIL"<br />

65.00'<br />

SIB<br />

(E&P)<br />

PART 1<br />

(ASPHALT)<br />

N44°29'50"E<br />

21.24'<br />

SIB<br />

(E&P)<br />

SIB<br />

(E&P)<br />

SSIB<br />

POST & PAGE WIRE FENCE<br />

"ROTARY GREENWAY TRAIL"<br />

P.I.N. 28465-0001<br />

X<br />

X<br />

(ASPHALT)<br />

N0°46'W<br />

"BUSH"<br />

N0°46'W<br />

P.I.N. 28465-0001<br />

"BUSH"<br />

X X<br />

POST & PAGE WIRE FENCE<br />

642.90'<br />

CHAIN LINK FENCE<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

1128.95'<br />

X<br />

486.05'<br />

SIB<br />

(E&P)<br />

SAND<br />

VOLLEYBALL COURT<br />

P.I.N. 28465-0061<br />

"BUSH"<br />

GRAVEL PATH<br />

(6' WIDE)<br />

(2' WIDE)<br />

ASPHALT DITCH<br />

(6' WIDE)<br />

GRAVEL PATH<br />

TOP OF STEEL<br />

CULVERT (1.0' DIA.)<br />

N72°58'50"E<br />

LOT 2<br />

METALCLAD<br />

GARAGE<br />

METAL CLAD<br />

GARAGE<br />

C L<br />

LOT LINE<br />

C L<br />

SOCCER POST<br />

SOCCER POST<br />

ASPHALT<br />

METAL CLAD<br />

GARAGE<br />

GRAVEL ROAD<br />

X<br />

GRAVEL<br />

WALK<br />

X X<br />

GOAL POST<br />

CONC.<br />

PAD<br />

CONC.<br />

PAD<br />

BOTTOM OF DITCH<br />

PAD<br />

CONC.<br />

GOAL POST<br />

ASPHALT<br />

CONCESSION 12<br />

GATE<br />

X<br />

CONC. WALK<br />

DOORSILL<br />

CHAIN LINK FENCE<br />

X X X<br />

BRICK<br />

SCHOOL<br />

TWO STOREY<br />

BLOCK 28710<br />

L<br />

C<br />

CONC. WALK<br />

X X<br />

STEEL FENCE<br />

TOP OF BANK<br />

ASPHALT<br />

STEPS &<br />

HAND RAILS<br />

FLOOR<br />

PETERBOROUGH<br />

CONDOMINIUMPLANNo. 10<br />

STEPS<br />

RAILING<br />

GLASS<br />

GREENHOUSES<br />

X<br />

X<br />

AREA=20.19 Acres<br />

C L<br />

CHIMNEY<br />

CONC. RAMP & RAILING<br />

CONC. RETAINING<br />

WALLS<br />

CONC.<br />

RET.<br />

WALL<br />

"GRASS FIELD"<br />

CONC.<br />

WALK<br />

STEPS &<br />

RAILING<br />

GRASS<br />

STEEL FENCE<br />

GRAVEL ROAD<br />

GATE<br />

"TRACK"<br />

BOTTOM OF DITCH<br />

F F<br />

LINE OF CURBS<br />

FLOOR<br />

CONC.<br />

RET.<br />

WALL<br />

WINDOW WELL<br />

ASPHALT<br />

THREE STOREY<br />

X<br />

BRICK<br />

SCHOOL<br />

X<br />

LC<br />

DOORSILL<br />

X<br />

ENCLOSED<br />

HYDRO<br />

ASPHALT<br />

614.02' (MEAS.)<br />

ASPHALT<br />

WALK<br />

CONC.<br />

PAD<br />

STEEL RAILING<br />

STEEL RAILING<br />

CONC. RET. WALL<br />

SOCCER POST<br />

SOCCER POST<br />

P.I.N. 28465-0061<br />

ENCLOSED<br />

AIR<br />

CONDITIONING<br />

UNIT<br />

CONC. RET.<br />

WALLS<br />

CONC. RET. WALL<br />

DOORSILL<br />

X<br />

C L<br />

X<br />

CONC.<br />

PAD<br />

GRAVEL ROAD<br />

"THOMAS A. STEWART SECONDARY SCHOOL"<br />

FLAG POLE<br />

CHAIN LINK FENCE<br />

PLAQUE<br />

SHRUBS<br />

ASPHALT<br />

CIVIC No. 1009<br />

FLOWER<br />

BED<br />

ASPHALT<br />

CONCESSION 12<br />

BLOCK 28709<br />

OIL TANK 5.DIA.<br />

SIB<br />

(1455)<br />

PETERBOROUGH<br />

CONDOMINIUMPLANNo. 9<br />

C L<br />

GOAL POST<br />

RAILING<br />

ASPHALT ENT.<br />

RAILING<br />

X X X X X X X<br />

LINE OF CURBS<br />

CONC.<br />

PAD<br />

N24°22'30"E<br />

CONC.<br />

PAD<br />

LINE OF CURBS<br />

CHAIN LINK FENCE<br />

129.21'<br />

X<br />

RAILING<br />

RAILING<br />

C L<br />

CONC. WALK<br />

N32°33'E<br />

25.18'<br />

IB<br />

X X X X X<br />

IB<br />

TOP BANK<br />

X<br />

ASPHALT<br />

ASPHALT<br />

X<br />

STEEL FENCE<br />

PLAN 45R10927<br />

PART 1<br />

X<br />

GRASS<br />

LINE OF CURBS<br />

LINE OF CURBS<br />

N62°51'40"W<br />

68.37'<br />

GRAVEL ROAD<br />

ASPHALT WALK<br />

X X<br />

STEEL FENCE<br />

ASPHALT<br />

X X<br />

X<br />

X<br />

STEEL FENCE<br />

IB<br />

TOP BANK<br />

DECK<br />

X X X<br />

X<br />

BEARING REFERENCE LINE<br />

17.04'<br />

IB<br />

GRASS<br />

ASPHALT TRACK<br />

X<br />

ASPHALT<br />

N23°17'20"E<br />

CONC. WALK<br />

ASPHALT TRACK<br />

CL<br />

X<br />

CHAIN LINK FENCE<br />

WOOD<br />

STEPS<br />

X<br />

X<br />

X X X X<br />

X<br />

X<br />

LINE OF CURBS<br />

LINE OF CURBS<br />

CHAIN LINK FENCE<br />

X<br />

CURB<br />

X<br />

CONC.<br />

MONUMENT<br />

GATE<br />

X<br />

X<br />

ASPHALT<br />

CHAIN LINK FENCE<br />

CURB<br />

X<br />

CHAIN LINK FENCE<br />

X<br />

"TENNIS COURTS" "TENNIS COURTS"<br />

SIB<br />

(E&P)<br />

189.21'<br />

X<br />

CHAIN LINK FENCE<br />

X<br />

X<br />

X<br />

X<br />

X<br />

PART 29<br />

LINE OF CURBS<br />

X X<br />

X<br />

ASPHALT<br />

SHRUBS<br />

X<br />

CENTRE LINE OF ROAD<br />

X<br />

GRASS<br />

BENCHES<br />

GRASS<br />

TOPNUT &<br />

N.E. ARM<br />

FIRE HYDRANT<br />

ASPHALT<br />

ASPHALT<br />

SHRUBS<br />

RAD.=553.11'<br />

CH.=249.32'<br />

ARC=251.48'<br />

CURB<br />

SSIB<br />

N2°45'40"W<br />

(PLAN & SET)<br />

PART 29<br />

EXPROPRIATION PLAN No. 177853<br />

N2°45'40"W<br />

SSIB<br />

N10°15'50"E<br />

LINE OF CURBS<br />

HYDRO POLE<br />

CENTRE LINE OF ROAD<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-1


Existing TASSS Building<br />

Ground Floor Plan<br />

STAGE<br />

64A<br />

GREEN HOUSE<br />

89B<br />

ECHANICAL RM<br />

LOWER<br />

B01<br />

ICAL RM<br />

B03<br />

G<br />

08<br />

OFF<br />

70F<br />

ITCHEN<br />

0<br />

70H<br />

W.R<br />

70E<br />

STORAGE GAR<br />

70G 70D<br />

CAFETERIA<br />

SERVICE<br />

70C<br />

SMALL<br />

CAFETERIA<br />

72<br />

TEACHERS<br />

DINING<br />

74<br />

STAIR<br />

S07<br />

67 STORAGE<br />

68<br />

STORAGE<br />

B06<br />

CORRIDOR H10 RAMP<br />

CUSTODIAN<br />

LOUNGE<br />

76<br />

CORRIDOR H09<br />

H11C<br />

OFFICERECEIVING<br />

68A 69<br />

METAL FABRICATION<br />

44<br />

SMALL ENGINE SHOP<br />

83<br />

STAIR<br />

S01<br />

CORRIDOR H13<br />

ART ROOM<br />

73<br />

ART ROOM<br />

78<br />

83A<br />

CORRIDOR H11<br />

44A<br />

CLASSROOM STOR<br />

75<br />

73A 43<br />

WELDING<br />

40<br />

WOOD SHOP<br />

85<br />

42<br />

STOR<br />

43A<br />

ENVIRONMENTAL LAB<br />

80<br />

Basement<br />

Second<br />

Floor<br />

Third<br />

Floor<br />

RAMP<br />

PAINT<br />

SHOP<br />

38B<br />

BUILDING TRADES<br />

87<br />

PAINT MIX<br />

38C<br />

STOR<br />

H01S<br />

COMP<br />

38A<br />

AUTO SHOP<br />

38<br />

H11WR<br />

CORRIDOR H12<br />

CORRIDOR H01<br />

H11J<br />

JAN<br />

H12C<br />

BOYS GIRLS STAIR OFFICE<br />

W.R W.R S08<br />

39A<br />

WORD H12A CLASSROOM<br />

H12B<br />

BUSINESS<br />

PROCESSING 39<br />

EDUCATION<br />

41<br />

STOR<br />

37<br />

39B<br />

ENVIRONMENTAL LAB<br />

84<br />

82<br />

DUST<br />

COLLECTOR<br />

87DC<br />

MEZZ<br />

87A<br />

Instructional<br />

Library/<br />

Resource<br />

Administration<br />

Building<br />

Services<br />

General Purpose<br />

/Community use<br />

89A<br />

36<br />

PREFAB<br />

GREEN<br />

HOUSE<br />

89C<br />

HORTICULTURE<br />

89<br />

STOR<br />

37A<br />

BROAD BASED<br />

MANUFACTURING<br />

34<br />

COMPUTER LAB<br />

35<br />

Storage<br />

Wash/<br />

Change<br />

Custodial<br />

Circulation<br />

Day Care<br />

COMPUTERS<br />

34A<br />

BROAD<br />

BASED<br />

DESIGN<br />

32<br />

COMPUTER LAB<br />

33<br />

STAIR<br />

S02<br />

V1<br />

OFFICE<br />

31<br />

W.R<br />

H02WR<br />

STAIR<br />

S03<br />

GYM<br />

STORAGE<br />

50<br />

DUCT<br />

SHAFT<br />

HO2DS<br />

JAN<br />

H02C<br />

CORRIDOR H02<br />

A.V<br />

ROOM<br />

29<br />

JAN<br />

H05C<br />

CLASSROOM<br />

27<br />

BOYS<br />

W.R<br />

H05WR<br />

CLASSROOM<br />

23<br />

STOR<br />

H03S3<br />

GYMNASIUM<br />

65<br />

GYMNASIUM<br />

STOR<br />

59C<br />

61<br />

CLASSROOM<br />

21<br />

CORRIDOR H05<br />

STOR<br />

H03S2<br />

CORRIDOR H03<br />

CLASSROOM<br />

17<br />

STOR<br />

59B<br />

HOME EC<br />

6<br />

CLASSROOM<br />

15<br />

DRYING<br />

65B<br />

MUD ROOM<br />

65 I<br />

SHOWERS<br />

65A<br />

BOYS CHANGE RM<br />

65C<br />

CORRIDOR 65H<br />

INST<br />

65D<br />

STOR 65G<br />

SHOWERS<br />

63G<br />

BOYS WR<br />

65F<br />

JAN H07C<br />

DRYING<br />

63 I<br />

GIRLS CHANGE RM<br />

63F<br />

INST<br />

63D<br />

GIRLS<br />

WR<br />

63J<br />

CORRIDOR 63H<br />

GIRLS CHANGE RM<br />

63C<br />

SHOWERS<br />

63A<br />

INST<br />

61D<br />

65E<br />

63E<br />

61E<br />

DRYING<br />

63B<br />

BOYS WR<br />

61F<br />

CORRIDOR 61H<br />

BOYS CHANGE RM<br />

61C<br />

SHOWERS<br />

61A<br />

59A<br />

CLASSROOM<br />

13<br />

GIRLS<br />

W.R<br />

H06WR<br />

H06<br />

STOR<br />

H03S<br />

DRYING<br />

61B<br />

STOR<br />

59<br />

CORRIDOR H04<br />

V2<br />

CORRIDOR H07<br />

TEACHERS WORK RM<br />

11<br />

STAIR<br />

S05<br />

CAFETERIA<br />

3<br />

STAIR<br />

S04<br />

THEATER<br />

WORK AREA<br />

66<br />

STOR<br />

60A<br />

ATHLETIC<br />

ASSOC<br />

60<br />

STAIR<br />

S06<br />

STOR<br />

B05<br />

AUDITORIUM<br />

64<br />

CORRIDOR H08<br />

CAFETERIA<br />

SERVICE<br />

70A<br />

64H<br />

MECHANICAL RM<br />

UPPER B03<br />

DISH WASHING<br />

70B<br />

STAGE<br />

64A<br />

MECHANICAL RM<br />

LOWER<br />

B01<br />

OFF<br />

70F<br />

KITCHEN<br />

70<br />

70H<br />

W.R<br />

70E<br />

STORAGE GAR<br />

70G 70D<br />

CAFETERIA<br />

SERVICE<br />

70C<br />

SMALL<br />

CAFETERIA<br />

72<br />

67 STORAGE<br />

68<br />

STORAGE<br />

B06<br />

TEACHERS<br />

DINING<br />

74<br />

STAIR<br />

S07<br />

CORRIDOR H10 RAMP<br />

CUSTODIAN<br />

LOUNGE<br />

76<br />

CORRIDOR H09<br />

H11C<br />

OFFICERECEIVING<br />

68A 69<br />

SMALL ENGINE SHOP<br />

83<br />

CORRIDOR H13<br />

ART ROOM<br />

73<br />

ART ROOM<br />

78<br />

83A<br />

CORRIDOR H11<br />

73A<br />

STOR<br />

75<br />

RAMP<br />

WOOD SHOP<br />

85<br />

ENVIRONMENTAL LAB<br />

80<br />

H11WR<br />

H11J<br />

DUST<br />

COLLECTOR<br />

87DC<br />

BOYS<br />

W.R<br />

H12A<br />

ENVIRONMENTAL LAB<br />

84<br />

82<br />

JAN<br />

H12C<br />

BUILDING TRADES<br />

87<br />

GIRLS<br />

W.R<br />

H12B<br />

MEZZ<br />

87A<br />

CORRIDOR H12<br />

STAIR<br />

S08<br />

GREEN HOUSE<br />

89B<br />

89A<br />

PREFAB<br />

GREEN<br />

HOUSE<br />

89C<br />

HORTICULTURE<br />

89<br />

Instructional<br />

Storage<br />

ZAS ARCHITECTS INC.<br />

Library/<br />

Wash/<br />

Basement<br />

Resource<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre Change | A-2<br />

Administration<br />

Custodial


Existing TASSS Building<br />

Second Floor Plan<br />

LIGHTING<br />

166B<br />

UPPER<br />

STAGE<br />

GREEN HOUSE ROOF<br />

TEMPORARY<br />

GREEN<br />

HOUSE<br />

STAIR<br />

S05<br />

STAIR<br />

S02<br />

UPPER GYM<br />

WEIGHT<br />

ROOM<br />

167<br />

ROOF<br />

134H<br />

RAMP<br />

LLS ROOM<br />

185<br />

ROOF<br />

ROOF<br />

FAN ROOM<br />

BOYS<br />

W.R<br />

H14B<br />

H14PC<br />

H14E<br />

SPECIAL NEEDS CLASSROOM<br />

187<br />

GIRLS<br />

W.R<br />

H14A<br />

JAN<br />

HI4C<br />

H14D<br />

COMMUNICATIONS<br />

TECHNOLOGY<br />

140<br />

COMMUNITY LIVING<br />

LAUNDRY<br />

189<br />

187A<br />

136D<br />

LAB<br />

140B<br />

COMMUNITY LIVING<br />

191<br />

140H 140A CAMERA DARK RM<br />

STOR<br />

RM 138 138A<br />

191A<br />

136C<br />

STRIVE PROGAM<br />

136<br />

ROOF<br />

136B<br />

136A<br />

SCIENCE RM<br />

134<br />

CLASSROOM<br />

132<br />

SCIENCE PREP<br />

134A<br />

CORRIDOR H20<br />

MUSIC ROOM<br />

166<br />

MUSIC STOR<br />

166A<br />

LIGHTING<br />

166B<br />

W.R<br />

170B<br />

VICE-<br />

PRINCIPAL<br />

170A<br />

VAULT<br />

170V<br />

GENERAL OFFICE<br />

170<br />

VESTIBULE<br />

E01<br />

STAIR<br />

S01<br />

BF<br />

W.R<br />

H23F<br />

CORRIDOR H23<br />

CHEMISTRY LAB<br />

141<br />

STOR<br />

H22S2<br />

SCHOOL<br />

STORE<br />

H23E<br />

STORAGE<br />

139A<br />

BF<br />

W.R<br />

CHEMISTRY LAB H23A<br />

139<br />

CUST<br />

H23C<br />

GIRLS<br />

W.R<br />

PHYSICS LAB<br />

H23B<br />

137<br />

H23PC<br />

QUIET<br />

CORRIDOR ROOM H14<br />

H23D<br />

STAIR<br />

S08<br />

SCIENCE<br />

OFFICE<br />

135A<br />

BIOLOGY & PHYSICS<br />

LAB<br />

135<br />

STORAGE<br />

133A<br />

GENERAL SCIENCE<br />

& PHYSICS LAB<br />

133<br />

CORRIDOR H15<br />

UPPER GYM<br />

EXERCISE<br />

ROOM<br />

163<br />

163A<br />

163C<br />

OFFICE<br />

163B<br />

STORAGE<br />

H20A<br />

BALCONY<br />

164<br />

UPPER<br />

AUDITORIUM<br />

UPPER<br />

STAGE<br />

GREEN HOUSE ROOF<br />

TEMPORARY<br />

GREEN<br />

HOUSE<br />

GUIDANCE<br />

COPY RM<br />

OFFICE<br />

170C<br />

170D<br />

STOR<br />

170G<br />

WOMEN'S<br />

H21D<br />

INTERVIEW<br />

W.R<br />

170E<br />

H21C W.R<br />

H2IB<br />

170H<br />

MEN'S<br />

INTERVIEW H21A<br />

170F<br />

WAITING<br />

OFFICE<br />

AREA<br />

172A<br />

172<br />

STOR<br />

SECRETARIES172C<br />

LOUNGE<br />

172B STOR<br />

172D<br />

W.R<br />

172E<br />

CORRIDOR H21<br />

OFFICE<br />

173A<br />

STOR<br />

H22S<br />

RESEARCH<br />

173<br />

CLASSROOM<br />

180<br />

CORRIDOR H22<br />

CO-OP<br />

OFFICE<br />

184<br />

CO-OP<br />

OFFICE<br />

182<br />

CAREER CENTER<br />

186<br />

COMMUNITY LIVING<br />

188<br />

TEACHERS<br />

LOUNGE<br />

131<br />

TEACHERS<br />

OFFICE 130<br />

130A<br />

STAIR<br />

S03<br />

BOOK<br />

STORAGE<br />

129<br />

JAN<br />

H15C<br />

H18PC<br />

BOYS<br />

W.R<br />

H18A<br />

STOR<br />

H126S2<br />

CORRIDOR H18<br />

H19PC<br />

GIRLS W.R<br />

H18B<br />

STAIR<br />

S06<br />

VESTIBULE<br />

H19<br />

CENTRAL<br />

ENTRANCE PLAZA<br />

LLS ROOM<br />

185<br />

RAMP<br />

ROOF<br />

SPECIAL NEEDS CLASSROOM<br />

187<br />

LAUNDRY<br />

187A<br />

COMMUNITY LIVING<br />

189<br />

COMMUNITY LIVING<br />

191<br />

ROOF<br />

STAIR<br />

S07<br />

TEACHERS<br />

WORK ROOM<br />

176<br />

CLASSROOM<br />

178<br />

Basement<br />

First<br />

Floor<br />

Third First<br />

Floor<br />

Instructional<br />

Library/<br />

Resource<br />

Administration<br />

Building<br />

Services<br />

General Purpose<br />

/Community use<br />

Alternative<br />

Program<br />

Storage<br />

Wash/<br />

Change<br />

Custodial<br />

Circulation<br />

Day Care<br />

CLASSROOM<br />

127<br />

CLASSROOM<br />

123<br />

CORRIDOR H16<br />

CLASSROOM<br />

121<br />

COMPUTER<br />

LAB<br />

120<br />

COMPUTER<br />

LAB<br />

117<br />

CLASSROOM<br />

115<br />

LIBRARY<br />

102<br />

102H<br />

COPY<br />

ROOM<br />

101C<br />

PRINCIPAL<br />

W.R<br />

101B<br />

101A<br />

GENERAL OFFICE<br />

101<br />

MEN'S<br />

VAULT<br />

105<br />

101G<br />

W.R W.R<br />

102A<br />

105A 107A<br />

STOR<br />

WOMEN'S 101F<br />

107<br />

STOR<br />

H16S<br />

TEACHERS LOUNGE<br />

104<br />

W.R<br />

104A<br />

CLASSROOM<br />

113<br />

TEACHERS WORK RM<br />

111<br />

CORRIDOR H17<br />

STAIR<br />

S04<br />

101H<br />

W.R<br />

170B<br />

VICE-<br />

PRINCIPAL<br />

101D<br />

VICE-<br />

PRINCIPAL<br />

101E<br />

VICE-<br />

PRINCIPAL<br />

170A<br />

VAULT<br />

170V<br />

GENERAL OFFICE<br />

170<br />

GUIDANCE<br />

COPY RM<br />

OFFICE<br />

170C<br />

170D<br />

STOR<br />

170G<br />

WOMEN'S<br />

H21D<br />

INTERVIEW<br />

W.R<br />

170E<br />

H21C W.R<br />

H2IB<br />

170H<br />

MEN'S<br />

INTERVIEW H21A<br />

170F<br />

WAITING<br />

OFFICE<br />

AREA<br />

172A<br />

172<br />

STOR<br />

SECRETARIES172C<br />

LOUNGE<br />

172B STOR<br />

172D<br />

W.R<br />

172E<br />

STAIR<br />

S07<br />

TEACHERS<br />

WORK ROOM<br />

176<br />

VESTIBULE<br />

E01<br />

CORRIDOR H21<br />

OFFICE<br />

173A<br />

STOR<br />

H22S<br />

CLASSROOM<br />

178<br />

RESEARCH<br />

173<br />

BF<br />

W.R<br />

H23F<br />

CORRIDOR H23<br />

CLASSROOM<br />

180<br />

CORRIDOR H22<br />

STOR<br />

H22S2<br />

CO-OP<br />

OFFICE<br />

184<br />

CO-OP<br />

OFFICE<br />

182<br />

SCHOOL<br />

STORE<br />

H23E<br />

CAREER CENTER<br />

186<br />

BF<br />

W.R<br />

H23A<br />

COMMUNITY LIVING<br />

188<br />

STOR<br />

191A<br />

CUST<br />

H23C<br />

GIRLS<br />

W.R<br />

H23B<br />

H23PC<br />

QUIET<br />

ROOM<br />

H23D<br />

STAIR<br />

S08<br />

ROOF<br />

Alternative<br />

Program<br />

Instructional<br />

Storage<br />

ZAS ARCHITECTS INC.<br />

Library/<br />

Wash/<br />

Basement<br />

Resource<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre Change | A-3<br />

Administration<br />

Custodial


Existing TASSS Building<br />

Third Floor Plan<br />

STAGE<br />

64A<br />

GREEN HOUSE<br />

89B<br />

RAMP<br />

PREFAB<br />

GREEN<br />

HOUSE<br />

89C<br />

ECHANICAL RM<br />

LOWER<br />

B01<br />

ICAL RM<br />

B03<br />

G<br />

08<br />

OFF<br />

70F<br />

ITCHEN<br />

0<br />

70H<br />

W.R<br />

70E<br />

STORAGE GAR<br />

70G 70D<br />

CAFETERIA<br />

SERVICE<br />

70C<br />

SMALL<br />

CAFETERIA<br />

72<br />

67 STORAGE<br />

68<br />

STORAGE<br />

B06<br />

TEACHERS<br />

DINING<br />

74<br />

CORRIDOR H10 RAMP<br />

CORRIDOR H09<br />

H11C<br />

OFFICERECEIVING<br />

68A 69<br />

ROOF<br />

SMALL ENGINE SHOP<br />

83<br />

CORRIDOR H13<br />

ART ROOM<br />

73<br />

83A<br />

CORRIDOR H11<br />

73A<br />

STOR<br />

75<br />

WOOD SHOP<br />

85<br />

ENVIRONMENTAL LAB<br />

80<br />

H11WR<br />

BOYS<br />

W.R<br />

H12A<br />

ENVIRONMENTAL LAB<br />

84<br />

82<br />

H11J<br />

DUST<br />

COLLECTOR<br />

87DC<br />

JAN<br />

H12C<br />

BUILDING TRADES<br />

87<br />

GIRLS<br />

W.R<br />

H12B<br />

MEZZ<br />

87A<br />

CORRIDOR H12<br />

STAIR<br />

S08<br />

ROOF<br />

89A<br />

HORTICULTURE<br />

89<br />

FAN ROOM<br />

S03A<br />

STAIR<br />

S03<br />

ROOF<br />

STORAGE<br />

229<br />

CLASSROOM<br />

227<br />

ROOF<br />

JAN<br />

H24C STOR<br />

H24S2<br />

ROOF<br />

ROOF<br />

UPPER<br />

LIBRARY<br />

FAN ROOM<br />

ROOF<br />

PHA<br />

UPPER<br />

BALCONY<br />

PROJEC-<br />

TION<br />

ROOM<br />

PHC<br />

ROOF<br />

ROOF<br />

ROOF<br />

ROOF<br />

ROOF<br />

STAIR<br />

S07<br />

CUSTODIAN<br />

LOUNGE<br />

76<br />

ART ROOM<br />

78<br />

CLASSROOM<br />

223<br />

CLASSROOM<br />

221<br />

CORRIDOR H24<br />

BALCONY<br />

102B<br />

ROOF<br />

ROOF<br />

UPPER RESEARCH<br />

STOR<br />

H25S2<br />

CLASSROOM<br />

286<br />

JAN<br />

H25C<br />

BOYS GIRLS<br />

W.R W.R<br />

H25A H25B<br />

STAIR<br />

S08<br />

Basement<br />

Second<br />

Floor<br />

Third<br />

Floor<br />

Instructional<br />

Library/<br />

Resource<br />

Administration<br />

Building<br />

Services<br />

General Purpose<br />

/Community use<br />

Storage<br />

Wash/<br />

Change<br />

Custodial<br />

Circulation<br />

Day Care<br />

CLASSROOM<br />

219<br />

CLASSROOM<br />

215<br />

CLASSROOM<br />

213<br />

STOR<br />

H24S<br />

TEACHERS WORK RM<br />

211<br />

STAIR<br />

S04<br />

FAN<br />

ROOM<br />

S04A<br />

STAIR<br />

S07<br />

FAN ROOM<br />

S07A<br />

TEACHERS<br />

WORK RM<br />

276<br />

STOR<br />

H25S<br />

CLASSROOM<br />

278<br />

BALCONY<br />

173B<br />

CORRIDOR H25<br />

CLASSROOM<br />

280<br />

CLASSROOM<br />

282<br />

CLASSROOM<br />

284<br />

FAN ROOM<br />

S08A<br />

Instructional<br />

Storage<br />

Basement<br />

Library/<br />

Resource<br />

Wash/<br />

Change<br />

ZAS ARCHITECTS INC.<br />

Administration<br />

Custodial<br />

First<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE Floor DISTRICT SCHOOL BOARD Education Centre | A-4<br />

Building<br />

Circulation<br />

Services<br />

Second First


Existing TASSS Building<br />

Basement Plan<br />

STAGE<br />

64A<br />

GREEN HOUSE<br />

89B<br />

RAMP<br />

PREFAB<br />

GREEN<br />

HOUSE<br />

89C<br />

ECHANICAL RM<br />

LOWER<br />

B01<br />

ICAL RM<br />

B03<br />

G<br />

08<br />

OFF<br />

70F<br />

ITCHEN<br />

0<br />

70H<br />

W.R<br />

70E<br />

STORAGE GAR<br />

70G 70D<br />

CAFETERIA<br />

SERVICE<br />

70C<br />

SMALL<br />

CAFETERIA<br />

72<br />

67 STORAGE<br />

68<br />

STORAGE<br />

B06<br />

TEACHERS<br />

DINING<br />

74<br />

CORRIDOR H10 RAMP<br />

CORRIDOR H09<br />

H11C<br />

OFFICERECEIVING<br />

68A 69<br />

SMALL ENGINE SHOP<br />

83<br />

CORRIDOR H13<br />

ART ROOM<br />

73<br />

83A<br />

CORRIDOR H11<br />

73A<br />

STOR<br />

75<br />

WOOD SHOP<br />

85<br />

ENVIRONMENTAL LAB<br />

80<br />

H11WR<br />

BOYS<br />

W.R<br />

H12A<br />

ENVIRONMENTAL LAB<br />

84<br />

82<br />

H11J<br />

DUST<br />

COLLECTOR<br />

87DC<br />

JAN<br />

H12C<br />

BUILDING TRADES<br />

87<br />

GIRLS<br />

W.R<br />

H12B<br />

MEZZ<br />

87A<br />

CORRIDOR H12<br />

STAIR<br />

S08<br />

89A<br />

HORTICULTURE<br />

89<br />

TRANS-<br />

FORMER<br />

B04A<br />

MECHANICAL<br />

ROOM B04<br />

BOILER<br />

ROOM<br />

B02A<br />

ELECTRICAL<br />

ROOM<br />

B02<br />

MECHANICAL RM<br />

B01<br />

STOR<br />

B07<br />

STAIR<br />

S07<br />

CUSTODIAN<br />

LOUNGE<br />

76<br />

ART ROOM<br />

78<br />

Instructional<br />

Storage<br />

Basement<br />

Library/<br />

Resource<br />

Wash/<br />

Change<br />

Second<br />

Floor<br />

Third<br />

Floor<br />

Administration<br />

Building<br />

Services<br />

General Purpose<br />

/Community use<br />

Custodial<br />

Circulation<br />

Day Care<br />

First<br />

Floor<br />

Instructional<br />

Library/<br />

Resource<br />

Storage<br />

Wash/<br />

Change<br />

ZAS ARCHITECTS INC.<br />

415 - TA Stewart SS Basement<br />

Second<br />

Administration<br />

Custodial<br />

Floor<br />

Building<br />

Circulation<br />

Services<br />

Third First<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT Floor<br />

SCHOOL BOARD General Education Purpose Centre | A-5<br />

Day Care<br />

/Community use


Plo ter<br />

Xerox (Main)<br />

Supplies<br />

Shelves Shelves Shelves Shelves Shelves<br />

Work Table & Supplies<br />

Shelves<br />

Shelves<br />

Table<br />

Shelves<br />

Shelves<br />

Security<br />

Alarm<br />

Pad<br />

Manager of Energy<br />

and Environmental<br />

Services<br />

151B<br />

MISA<br />

BUS/FIN<br />

PLANNING<br />

COFFEE<br />

Manager 151A<br />

Custodial<br />

Operations<br />

151<br />

Manager of<br />

Maintenance<br />

Services<br />

Controller 150<br />

of Facilities<br />

Services<br />

Secretary<br />

149C<br />

149D<br />

149A<br />

149F<br />

149B<br />

[149]<br />

STAIR No 4<br />

[138]<br />

BUS/FIN<br />

OFFICE<br />

[139A]<br />

BUS/FIN<br />

OFFICE<br />

[139B]<br />

OFFICE<br />

[137] [136]<br />

ADMINISTRATIVE SERVICES<br />

126A<br />

GENERAL OFFICE AREA<br />

[126]<br />

PURCHASING SERVICES<br />

126B<br />

STAIR No 3<br />

LEADERSHIP &<br />

ADMIN<br />

STAFF DEVELOP.<br />

ASSIST<br />

[118]<br />

BUS/FIN<br />

[111]<br />

OFFICE<br />

EXIST<br />

[112]<br />

ELEV<br />

MEETING<br />

ROOM<br />

[113]<br />

WRM LINK<br />

[115] [114]<br />

Existing KPRDSB Education Centre<br />

First floor plan<br />

ADMIN<br />

OFFICE<br />

[125]<br />

ADMIN PURCHASING PURCHASING Communications Communications<br />

OFFICE<br />

OFFICER OFFICER<br />

OFFICE OFFICE<br />

[124] [123]<br />

[122]<br />

[121]<br />

[120]<br />

EXEC<br />

ASSIST<br />

[119]<br />

[117]<br />

ADMIN<br />

ASSIST<br />

DIRECTOR<br />

[116]<br />

ICT Department<br />

Facilities Services General<br />

Facilities Services Maint. Shops<br />

Leadership & Development<br />

Teaching & Learning<br />

Finance Depattment<br />

Meeting Rooms<br />

Mail, Courier & Print Centre<br />

Director's Suite<br />

Director's Secure Records<br />

Senior Administration<br />

Human Resorces<br />

Human Resources Secure Records<br />

<strong>Board</strong> Room & Trustees<br />

General Office - Various Departments<br />

NOTE:<br />

Please reference the Tender Documents regarding additional spaces<br />

and reduced spaces required as part of the <strong>Feasibility</strong> <strong>Study</strong><br />

at Thomas A. Stewart S.S.<br />

- Staff located in the Peterborough C.E.C. offices, plus ICT Service<br />

providers as shown in Addendum # 1.<br />

Reduced space in LRC for Professional Library & Training Room and<br />

Half the area of Existing Warehouse, etc.<br />

181D<br />

181C<br />

181E<br />

MEETING<br />

ROOM<br />

181F<br />

MEETING<br />

ROOM<br />

181G<br />

181I<br />

HALLWAY<br />

181H<br />

WAREHOUSE and ARCHIVAL STORAGE<br />

[180]<br />

Planning Department<br />

Warehouse & Archival Storage<br />

181B<br />

181J<br />

Purchasing Department<br />

Central Services<br />

Building Services<br />

Storage - Misc.<br />

Staff Lunch Room<br />

Work Room<br />

Washrooms<br />

Circulation<br />

181A<br />

FACILITIES SERVICES<br />

Basement<br />

MAINTENANCE SHOP<br />

Second<br />

Floor<br />

[181]<br />

181K<br />

181M<br />

181L<br />

RESOURCES<br />

/MEDIA<br />

[175K]<br />

RESOURCE<br />

PREP AREA<br />

[175J]<br />

COURIER<br />

[179]<br />

EDUCATION CENTRE - 1st FLOOR<br />

OFFICE<br />

[175D]<br />

OFFICE<br />

[175E]<br />

BOOKING<br />

[175F]<br />

VIDEO<br />

DUB/EDIT<br />

[175G]<br />

SOFTWARE<br />

DUBBING<br />

[175H]<br />

MAIL<br />

[178]<br />

LEARNING RESOURCE CENTRE<br />

FACILITIES SERVICES<br />

MAINTENANCE SHOP<br />

[164]<br />

CATALOG<br />

LIB/TECH<br />

MEETING/PREVIEW<br />

WORK ROOM<br />

[175]<br />

PROF LIBRARY<br />

HALLWAY 176<br />

[175C]<br />

[175B]<br />

[175A]<br />

PRINT<br />

[177]<br />

STAIR No 2<br />

CNTRL<br />

Facilities Services Records Storage<br />

Facilities Services<br />

Tool Storage<br />

WRM<br />

(164E)<br />

STAIR No 1<br />

TECH<br />

[164B] [164C] [164D]<br />

[164A]<br />

SHOWER SHOWER<br />

AREA<br />

AREA<br />

MENS<br />

WOMENS<br />

[168]<br />

CUSTODIAL<br />

[171]<br />

MEETING<br />

WRM<br />

WRM<br />

MECH/ELECT<br />

LOBBY<br />

ROOM<br />

[167]<br />

[170]<br />

[173]<br />

VEST<br />

VESTIBULE<br />

[102]<br />

ELEV EQ.<br />

[163] [165]<br />

ENTRY<br />

ENTRY LAN<br />

ELEV<br />

[101]<br />

[166]<br />

[169] [172]<br />

[174] E2<br />

EF-16<br />

EF-15<br />

CORRIDOR<br />

[154]<br />

EF-14<br />

EF-17<br />

INTERVIEW<br />

[160]<br />

COATS<br />

[104]<br />

BOARD ROOM<br />

[103]<br />

MEETING<br />

TRAINING<br />

MEETING<br />

MEETING<br />

[156]<br />

ROOM<br />

SECURE<br />

STAFF ROOM<br />

H.R.<br />

[161]<br />

[162]<br />

FILES<br />

[153]<br />

PLAN ROOM [148]<br />

151D<br />

Supervisor of<br />

Engineering<br />

149J<br />

149L<br />

Services<br />

FACILITIES SERVICES DEPARTMENT<br />

151C<br />

149K<br />

Asset<br />

Management<br />

HR Specialist<br />

Co-ordinator<br />

General<br />

Administration<br />

Keys Keys Keys<br />

HALLWAY 152<br />

ROOM<br />

[159]<br />

Senior Manager Team Leader Team Leader<br />

Human<br />

Staffing & Benefits &<br />

Resources Employment<br />

Data<br />

Services<br />

Services Management<br />

[147] [146]<br />

[145]<br />

HUMAN RESOURCES<br />

ROOM<br />

[158]<br />

Team Leader<br />

Payroll<br />

Services<br />

[144]<br />

ROOM<br />

[157]<br />

Sr. Consultant Employee &<br />

Employee<br />

Labour<br />

Relations Relations<br />

[143]<br />

[142]<br />

Employee<br />

Relations<br />

[140]<br />

INTERVIEW<br />

/MEETING<br />

[155]<br />

Sr. Consultant<br />

Employee<br />

Relations<br />

[141]<br />

Leadership<br />

Development &<br />

Staff Training<br />

EF-18<br />

HALLWAY 139<br />

[106E]<br />

TRUSTEES<br />

WORKROOM<br />

STORAGE<br />

[105]<br />

CHAIRS<br />

OFFICE<br />

[135]<br />

BUS/FIN BUS/FIN<br />

OFFICE OFFICE<br />

[134] [133]<br />

[106]<br />

EF-19<br />

EXIST<br />

CUST<br />

WRM<br />

[131]<br />

EXIST<br />

[127]<br />

WRM<br />

[130]<br />

GEN<br />

ADMIN. BUS/FIN<br />

OFFICE<br />

OFFICE<br />

Work Room OFFICE<br />

[110]<br />

[132]<br />

[129] [128]<br />

HALLWAY 107<br />

H.R.<br />

OFFICE<br />

[108]<br />

ADMIN<br />

OFFICE<br />

[109]<br />

Manager of Energy<br />

and Environmental<br />

Services<br />

151B<br />

MISA<br />

BUS/FIN<br />

PLANNING<br />

COFFEE<br />

Manager 151A<br />

Custodial<br />

Operations<br />

151<br />

Manager of<br />

Maintenance<br />

Services<br />

Controller 150<br />

of Facilities<br />

Services<br />

Secretary<br />

149C<br />

149D<br />

149A<br />

149F<br />

149B<br />

[149]<br />

STAIR No 4<br />

[138]<br />

BUS/FIN<br />

OFFICE<br />

[139A]<br />

OFFICE<br />

[137] [136]<br />

ADMINISTRATIVE SERVICES<br />

126A<br />

GENERAL OFFICE AREA<br />

[126]<br />

PURCHASING SERVICES<br />

126B<br />

STAIR No 3<br />

BUS/FIN<br />

[111]<br />

OFFICE<br />

EXIST<br />

[112]<br />

ELEV<br />

MEETING<br />

ROOM<br />

[113]<br />

BUS/FIN<br />

OFFICE<br />

[139B]<br />

LEADERSHIP &<br />

ADMIN<br />

STAFF DEVELOP.<br />

ASSIST<br />

[118]<br />

WRM<br />

[115]<br />

LINK<br />

[114]<br />

ADMIN<br />

OFFICE<br />

[125]<br />

ADMIN PURCHASING PURCHASING Communications Communications<br />

OFFICE<br />

OFFICER OFFICER<br />

OFFICE OFFICE<br />

[124] [123]<br />

[122]<br />

[121]<br />

[120]<br />

EXEC<br />

ASSIST<br />

[119]<br />

[117]<br />

ADMIN<br />

ASSIST<br />

DIRECTOR<br />

[116]<br />

ICT Department<br />

ZAS ARCHITECTS INC.<br />

Facilities Services General<br />

Director's Suite<br />

Facilities Services<br />

<strong>Feasibility</strong><br />

Maint. Shops<br />

<strong>Study</strong> for Director's the KAWartha Secure Records PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-6<br />

Leadership & Development<br />

Senior Administration<br />

NOTE: Please reference the Tender Documents regarding additional spaces<br />

Teaching & Learning<br />

Human Resorces<br />

and reduced spaces required as part of the <strong>Feasibility</strong> <strong>Study</strong><br />

at Thomas A. Stewart S.S.


Existing KPRDSB Education Centre<br />

Second floor plan<br />

ICT Department<br />

Facilities Services General<br />

Director's Suite<br />

Facilities Services Maint. Shops<br />

Director's Secure Records<br />

Leadership & Development<br />

Teaching & Learning<br />

Finance Depattment<br />

Meeting Rooms<br />

Mail, Courier & Print Centre<br />

Senior Administration<br />

Human Resorces<br />

Human Resources Secure Records<br />

<strong>Board</strong> Room & Trustees<br />

General Office - Various Departments<br />

NOTE:<br />

Please reference the Tender Documents regarding additional spaces<br />

and reduced spaces required as part of the <strong>Feasibility</strong> <strong>Study</strong><br />

at Thomas A. Stewart S.S.<br />

- Staff located in the Peterborough C.E.C. offices, plus ICT Service<br />

providers as shown in Addendum # 1.<br />

Reduced space in LRC for Professional Library & Training Room and<br />

Half the area of Existing Warehouse, etc.<br />

Planning Department<br />

Warehouse & Archival Storage<br />

Purchasing Department<br />

Staff Lunch Room<br />

Central Services<br />

Building Services<br />

Work Room<br />

Washrooms<br />

Basement<br />

Storage - Misc.<br />

Circulation<br />

First<br />

Floor<br />

EDUCATION CENTRE - 2nd FLOOR<br />

STAIR No 2<br />

STAIR No 1<br />

OFFICE<br />

[220]<br />

OFFICE<br />

[219]<br />

DN<br />

OFFICE<br />

[218]<br />

OFFICE<br />

[217]<br />

OFFICE<br />

[216]<br />

OFFICE OFFICE OFFICE OFFICE OFFICE<br />

[215] [214] [213] [212] [211]<br />

CUST<br />

BF BF [221]<br />

WRM WRM<br />

[210] [209]<br />

ELEV<br />

MEETING<br />

ROOM<br />

200<br />

MEETING<br />

ROOM<br />

LOBBY [202]<br />

208L<br />

DN<br />

WORK ROOM<br />

[203]<br />

UPPER<br />

BOARD ROOM<br />

[103]<br />

GENERAL OFFICE<br />

SECURE FILES<br />

[204]<br />

[208]<br />

GUARD WALL FULL WIDTH OF<br />

GENERAL OFFICE AS DETAILED<br />

WORKRM<br />

[207]<br />

WORKRM<br />

[206]<br />

WORKRM<br />

[205]<br />

ZAS ARCHITECTS INC.<br />

ICT Department<br />

Facilities Services General<br />

Director's Suite<br />

<strong>Feasibility</strong> Facilities Services Maint. <strong>Study</strong> Shops for the KAWartha Director's Secure PINE Records RIDGE DISTRICT SCHOOL BOARD Education Centre | A-7<br />

Leadership & Development<br />

Senior Administration<br />

NOTE: Please reference the Tender Documents regarding additional spaces<br />

and reduced spaces required as part of the <strong>Feasibility</strong> <strong>Study</strong><br />

Teaching & Learning<br />

Human Resorces<br />

at Thomas A. Stewart S.S.


Routers/Switches<br />

and Servers (1)<br />

B08<br />

B22<br />

Manager of Energy<br />

and Environmental<br />

Services<br />

151B<br />

MISA<br />

BUS/FIN<br />

PLANNING<br />

COFFEE<br />

Manager 151A<br />

Custodial<br />

Operations<br />

151<br />

Manager of<br />

Maintenance<br />

Services<br />

Controller 150<br />

of Facilities<br />

Services<br />

Secretary<br />

149C<br />

149D<br />

149A<br />

149F<br />

149B<br />

[149]<br />

STAIR No 4<br />

[138]<br />

BUS/FIN<br />

OFFICE<br />

[139A]<br />

BUS/FIN<br />

OFFICE<br />

[139B]<br />

OFFICE<br />

[137] [136]<br />

ADMINISTRATIVE SERVICES<br />

126A<br />

GENERAL OFFICE AREA<br />

[126]<br />

PURCHASING SERVICES<br />

126B<br />

STAIR No 3<br />

LEADERSHIP &<br />

ADMIN<br />

STAFF DEVELOP.<br />

ASSIST<br />

[118]<br />

BUS/FIN<br />

[111]<br />

OFFICE<br />

EXIST<br />

[112]<br />

ELEV<br />

MEETING<br />

ROOM<br />

[113]<br />

WRM LINK<br />

[115] [114]<br />

Existing KPRDSB Education Centre<br />

Basement plan<br />

ADMIN<br />

OFFICE<br />

[125]<br />

ADMIN PURCHASING PURCHASING Communications Communications<br />

OFFICE<br />

OFFICER OFFICER<br />

OFFICE OFFICE<br />

[124] [123]<br />

[122]<br />

[121]<br />

[120]<br />

EXEC<br />

ASSIST<br />

[119]<br />

[117]<br />

ADMIN<br />

ASSIST<br />

DIRECTOR<br />

[116]<br />

ICT Department<br />

Facilities Services General<br />

Director's Suite<br />

Facilities Services Maint. Shops<br />

Director's Secure Records<br />

Leadership & Development<br />

Teaching & Learning<br />

Finance Depattment<br />

Meeting Rooms<br />

Mail, Courier & Print Centre<br />

Senior Administration<br />

Human Resorces<br />

Human Resources Secure Records<br />

<strong>Board</strong> Room & Trustees<br />

General Office - Various Departments<br />

NOTE:<br />

Please reference the Tender Documents regarding additional spaces<br />

and reduced spaces required as part of the <strong>Feasibility</strong> <strong>Study</strong><br />

at Thomas A. Stewart S.S.<br />

- Staff located in the Peterborough C.E.C. offices, plus ICT Service<br />

providers as shown in Addendum # 1.<br />

Reduced space in LRC for Professional Library & Training Room and<br />

Half the area of Existing Warehouse, etc.<br />

Planning Department<br />

Warehouse & Archival Storage<br />

Purchasing Department<br />

Staff Lunch Room<br />

Central Services<br />

Building Services<br />

Work Room<br />

Washrooms<br />

Basement<br />

Storage - Misc.<br />

Circulation<br />

Second<br />

Floor<br />

EDUCATION CENTRE - 1st FLOOR<br />

ELECTRIC<br />

& SEWAGE PUMP<br />

B20<br />

ICT VENDOR SUPPORT<br />

B21<br />

ICT VENDOR<br />

SUPPORT<br />

B22<br />

OFFICE<br />

B23<br />

B18<br />

B19<br />

WOMEN'S<br />

WASHROOM<br />

MEN'S<br />

WASHROOM<br />

B24<br />

TECH REPAIR<br />

[B17]<br />

OFFICE<br />

[B10]<br />

OFFICE<br />

[B11]<br />

OFFICE<br />

[B12]<br />

OFFICE<br />

[B13]<br />

COMPUTER<br />

ROOM<br />

[B14]<br />

COMPUTER<br />

SERVERS<br />

[B16]<br />

EQUIP<br />

[B26]<br />

ELEV<br />

E1<br />

MEETING<br />

ROOM<br />

[B25]<br />

COFFEE<br />

[B15]<br />

STAIR No 3<br />

LOBBY<br />

[B02]<br />

VEST<br />

[B01]<br />

TECHNOLOGY & INFORMATION<br />

GENERAL OFFICE<br />

[B08]<br />

OFFICE<br />

[B07]<br />

B03<br />

STAIR No 4<br />

MEETING ROOM<br />

CHIEF<br />

INFORMATION<br />

OFFICER<br />

OFFICE<br />

[B06]<br />

OFFICE<br />

[B05]<br />

OFFICE<br />

[B04]<br />

[B03]<br />

[B09]<br />

ZAS ARCHITECTS INC.<br />

ICT Department<br />

Facilities Services General<br />

Facilities Services Maint. Shops<br />

Director's Suite<br />

Director's Secure Records<br />

Leadership & <strong>Feasibility</strong> Development <strong>Study</strong> for the Senior KAWartha Administration PINE RIDGE DISTRICT NOTE: SCHOOL Please reference BOARD the Tender Documents Education regarding additional Centre spaces | A-8<br />

and reduced spaces required as part of the <strong>Feasibility</strong> <strong>Study</strong><br />

Teaching & Learning<br />

Human Resorces<br />

at Thomas A. Stewart S.S.<br />

Finance Depattment<br />

Human Resources Secure Records<br />

- Staff located in the Peterborough C.E.C. offices, plus ICT Service<br />

providers as shown in Addendum # 1.


Existing KPRDSB Education Centre<br />

Matrix<br />

Priority Adjaceny Matrix<br />

Project:<br />

Date:<br />

KPRDSB <strong>Feasibility</strong> <strong>Study</strong><br />

11-098<br />

10-Aug-11<br />

ICT Dept<br />

Facilities<br />

Services (Gen)<br />

Facilities<br />

Services<br />

(Maint)<br />

Leadership &<br />

Development<br />

Teaching &<br />

Learning<br />

Finance<br />

Dept<br />

Meeting<br />

Rooms<br />

Mail,<br />

Courier &<br />

Print<br />

Planning<br />

Dept<br />

Purchasing<br />

Dept<br />

Central<br />

Services<br />

Building<br />

Services<br />

Director's<br />

Suite<br />

Senior<br />

Administration<br />

Human<br />

Resources<br />

<strong>Board</strong> Room<br />

& Trustees<br />

General<br />

Office<br />

Warehouse<br />

Lunch<br />

Room<br />

Work<br />

Room<br />

ICT Dept - - - - - - - - - - - - - - - - - - -<br />

Facilities Services (Gen) 1 - - - - - - - - - - - - - - - - - -<br />

Facilities Services (Maint) 1 3 - - - - - - - - - - - - - - - - -<br />

Leadership & Development - - - - - - - - - - - - - - - -<br />

Teaching & Learning 2 1 1 - - - - - - - - - - - - - - -<br />

Finance Dept 2 1 1 1 - - - - - - - - - - - - - -<br />

Meeting Rooms 2 1 1 1 1 - - - - - - - - - - - - -<br />

Mail, Courier & Print 1 1 1 1 1 1 - - - - - - - - - - - -<br />

Planning Dept 1 1 1 1 1 1 1 - - - - - - - - - - -<br />

Purchasing Dept - - - - - - - - - -<br />

Central Services - - - - - - - - -<br />

Building Services 1 1 1 1 1 1 1 1 - - - - - - - -<br />

Director's Suite 1 1 1 1 1 1 1 3 1 - - - - - - -<br />

Senior Administration 1 1 1 1 1 1 1 3 1 3 - - - - - -<br />

Human Resources 2 1 1 1 3 1 1 1 1 1 1 - - - - -<br />

<strong>Board</strong> Room & Trustees 1 1 1 1 1 1 1 1 1 3 3 1 - - - -<br />

General Office - - -<br />

Warehouse 2 1 3 or 1 1 1 1 3 1 3 1 1 1 1 - -<br />

Lunch Room 1 1 1 1 1 1 1 1 2 1 1 1 1 1 -<br />

Work Room<br />

Prefered Floor Level 1 1 1 1 3 2 or 3 1 2 1 2 2 3 2 1 1<br />

* Please rank space adjacencies 1 (low priority) to 3 (High Priority)<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-9


Summary of Schematic Options Investigated<br />

Site plan option 1<br />

Existing asphalt area repaved and re-striped to City of<br />

Peterborough Zoning standards.<br />

Parking Spaces: 283 (including 7 accessible spaces).<br />

Existing loading area re-used.<br />

New bus loop provided.<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-10


Summary of Schematic Options Investigated<br />

Site plan option 2<br />

Existing asphalt area repaved and re-striped to City of<br />

Peterborough Zoning standards. Existing tennis courts removed<br />

and renovated into new paved area.<br />

Parking Spaces: 359 (including 9 accessible spaces).<br />

Existing loading area re-used.<br />

New bus loop provided.<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-11


Proposed TASSS Re-purposing<br />

Site plan diagram<br />

5<br />

8<br />

4<br />

3<br />

7<br />

6<br />

11<br />

ENTRANCE<br />

FIRE ROUTE<br />

1<br />

2<br />

REPURPOSED / SPECIALIZED SCHOOL MAIN ENTRANCE<br />

COMMUNITY USE PRIMARY ENTRANCE<br />

10<br />

9<br />

10<br />

2<br />

1<br />

12<br />

9<br />

10<br />

DELIVERY ROUTE<br />

SCHOOL BUS ROUTE<br />

3<br />

4<br />

EDUCATION CENTRE BARRIER-FREE ENTRANCE<br />

COURIER / SHIPPING / RECEIVING ENTRANCE<br />

5<br />

6<br />

MAINTENANCE SHOPS ENTRANCE<br />

COMMUNITY USE SECONDARY ENTRANCE<br />

13<br />

7<br />

EDUCATION CENTRE MAIN ENTRANCE<br />

8<br />

SECURE PARKING, STORAGE AND RECEIVING<br />

9<br />

ACCESSIBLE PARKING SPACES<br />

10<br />

VISITOR PARKING<br />

11<br />

EDUCATION CENTRE DROP-OFF<br />

12<br />

13<br />

COMMUNITY DROP-OFF/ BUS LOOP<br />

PYLON SIGN<br />

13<br />

ARMOUR ROAD<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-12


Proposed TASSS Re-purposing<br />

Site plan<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-13


FIR<br />

SE<br />

1<br />

2<br />

Proposed TASSS Re-purposing<br />

Major use analysis<br />

3<br />

4<br />

FIRST FLOOR<br />

5<br />

6 7<br />

8<br />

9 10<br />

SECOND FLOOR<br />

ENTRANCE<br />

1<br />

REPURPOSED / SPECIALIZED SCHOOL MAIN ENTRANCE<br />

ED SCHOOL MAIN ENTRANCE<br />

ENTRANCE<br />

IER-FREE ENTRANCE<br />

EIVING ENTRANCE<br />

RANCE<br />

ARY ENTRANCE<br />

ENTRANCE<br />

ELEVATOR<br />

ACCESS CONTROL POINT<br />

EDUCATION CENTRE<br />

COMMUNITY USE<br />

REPURPOSED / SPECIALIZED SCHOOL<br />

CAFETERIA<br />

BUILDING SERVICES<br />

CIRCULATION<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

COMMUNITY USE PRIMARY ENTRANCE<br />

EDUCATION CENTRE BARRIER-FREE ENTRANCE<br />

COURIER / SHIPPING / RECEIVING ENTRANCE<br />

MAINTENANCE SHOPS ENTRANCE<br />

COMMUNITY USE SECONDARY ENTRANCE<br />

EDUCATION CENTRE MAIN ENTRANCE<br />

INFO / RECEPTION<br />

EDUCATION CENTRE OFFICE ENTRANCE<br />

E ENTRANCE<br />

STAIRS<br />

10<br />

BOARD ROOM ENTRANCE<br />

TH<br />

THIRD FLOOR<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-14


Proposed TASSS Re-purposing<br />

First floor plan<br />

NEW CANOPY ABOVE<br />

REPURPOSED /<br />

SPECIALIZED<br />

SCHOOL ENTRANCE<br />

ELEV.<br />

MACH.<br />

STORAGE<br />

(VARIOUS DEPARTMENTS)<br />

BARRIER-FREE<br />

ENTRANCE<br />

ELEV.<br />

MACH.<br />

LOBBY<br />

ELEV.<br />

MACH.<br />

VIDEO<br />

DUB / EDIT<br />

RESOURCE<br />

PREP AREA<br />

WAREHOUSE<br />

&<br />

ARCHIVES<br />

PRINT<br />

CENTRE<br />

MAIL<br />

ROOM<br />

RECEIVING /<br />

COURIER<br />

SOFTWARE<br />

DUBBING<br />

SERVERY<br />

KITCHEN<br />

STORAGE<br />

CATALOGUE / LIBRARY<br />

/ TECH.<br />

RESOURCES /<br />

MEDIA<br />

DISHWASHING<br />

MAINTENANCE<br />

RECORDS<br />

MEETING / PREVIEW<br />

WORK ROOM<br />

CAFETERIA<br />

STORAGE<br />

MAINT.<br />

SHOP<br />

MAINT.<br />

SHOP<br />

MAINT.<br />

SHOP<br />

CONTROL<br />

TECH.<br />

TOOL<br />

STORAGE<br />

MAINT.<br />

SHOP<br />

ELEV.<br />

MACH.<br />

ICT DEPARTMENT<br />

DIRECTOR’S SUITE<br />

OFFICE<br />

BOOKING<br />

FACILITIES SERVICES<br />

MAINTENANCE SHOP<br />

FACILITIES SERVICES OFFICES<br />

DIRECTOR’S SECURE RECORDS<br />

OFFICE<br />

FACILITIES SERVICES MAINT. SHOPS<br />

SENIOR ADMINISTRATION<br />

LEARNING<br />

RESOURCE<br />

CENTRE<br />

LEADERSHIP & DEVELOPMENT<br />

TEACHING & LEARNING<br />

HUMAN RESOURCES<br />

HUMAN RESOURCES SECURE RECORDS<br />

MEETING<br />

ROOM<br />

FINANCE DEPARTMENT<br />

BOARD ROOM & TRUSTEES<br />

MEETING ROOMS<br />

MAIL, COURIER & PRINT CENTRE<br />

PLANNING DEPARTMENT<br />

PURCHASING DEPARTMENT<br />

CENTRAL SERVICES<br />

BUILDING SERVICES<br />

STORAGE - MISC.<br />

LEARNING RESOURCE CENTRE<br />

GENERAL OFFICE - VARIOUS DEPARTMENTS<br />

WAREHOUSE & ARCHIVAL STORAGE<br />

CAFETERIA<br />

WORK ROOM<br />

WASHROOMS<br />

CIRCULATION<br />

COMMUNITY USE<br />

REPURPOSED / SPECIALIZED SCHOOL<br />

WORK<br />

ROOM<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-15


Proposed TASSS Re-purposing<br />

Second floor plan<br />

NEW CANOPY<br />

OPEN TO BELOW<br />

OPEN TO BELOW<br />

OPEN TO BELOW<br />

NEW CANOPY ABOVE<br />

MEETING<br />

ROOM<br />

MEETING<br />

ROOM<br />

ICT SERVER & MAIN<br />

COMPUTER ROOM<br />

COMMUNITY USE<br />

ENTRANCE LOBBY<br />

EDUCATION CENTRE &<br />

COMMUNITY USE<br />

ENTRY COURT<br />

EDUCATION CENTRE<br />

ENTRANCE LOBBY<br />

MEETING<br />

ROOM<br />

MEETING<br />

ROOM<br />

MEETING<br />

ROOM<br />

MEETING<br />

ROOM<br />

MEETING<br />

ROOM<br />

DRAWING<br />

RECORDS<br />

INTER-<br />

VIEW<br />

INFORMATION &<br />

TECHNOLOGY<br />

OFFICE<br />

ICT<br />

EQUIPMENT<br />

REPAIR<br />

GENERAL<br />

OFFICE AREA<br />

INTER-<br />

VIEW<br />

CHAIR<br />

TRUSTEE<br />

WORK ROOM<br />

PLAN.<br />

BOARD<br />

ROOM<br />

ICT DEPARTMENT<br />

FACILITIES SERVICES OFFICES<br />

DIRECTOR’S SUITE<br />

DIRECTOR’S SECURE RECORDS<br />

GENERAL<br />

OFFICE AREA<br />

COMM.<br />

OFFICER<br />

COMM.<br />

OFFICER<br />

FACILITIES<br />

SERVICES OFFICE<br />

FACILITIES SERVICES MAINT. SHOPS<br />

LEADERSHIP & DEVELOPMENT<br />

TEACHING & LEARNING<br />

SENIOR ADMINISTRATION<br />

HUMAN RESOURCES<br />

HUMAN RESOURCES SECURE RECORDS<br />

ICT SERVICE<br />

PROVIDER<br />

SENIOR ADMIN.<br />

WORK ROOM<br />

STORAGE<br />

ADMIN.<br />

ASSIST.<br />

EXEC.<br />

ASSIST.<br />

FINANCE DEPARTMENT<br />

BOARD ROOM & TRUSTEES<br />

DIRECTOR<br />

MEETING ROOMS<br />

MAIL, COURIER & PRINT CENTRE<br />

PLANNING DEPARTMENT<br />

PURCHASING DEPARTMENT<br />

CENTRAL SERVICES<br />

BUILDING SERVICES<br />

STORAGE - MISC.<br />

LEARNING RESOURCE CENTRE<br />

GENERAL OFFICE - VARIOUS DEPARTMENTS<br />

WAREHOUSE & ARCHIVAL STORAGE<br />

CAFETERIA<br />

WORK ROOM<br />

WASHROOMS<br />

CIRCULATION<br />

COMMUNITY USE<br />

REPURPOSED / SPECIALIZED SCHOOL<br />

MEETING<br />

ROOM<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-16


Proposed TASSS Re-purposing<br />

Third floor plan<br />

NEW CANOPY<br />

NEW CANOPY<br />

OPEN TO BELOW<br />

TEACHING &<br />

LEARNING OFFICE<br />

OPEN TO BELOW<br />

LEADERSHIP<br />

&<br />

DEVELOPMENT<br />

ICT DEPARTMENT<br />

FACILITIES SERVICES OFFICES<br />

FACILITIES SERVICES MAINT. SHOPS<br />

DIRECTOR’S SUITE<br />

DIRECTOR’S SECURE RECORDS<br />

SENIOR ADMINISTRATION<br />

HUMAN<br />

RESOURCES<br />

OFFICE<br />

LEADERSHIP & DEVELOPMENT<br />

TEACHING & LEARNING<br />

FINANCE DEPARTMENT<br />

HUMAN RESOURCES<br />

HUMAN RESOURCES SECURE RECORDS<br />

BOARD ROOM & TRUSTEES<br />

STORAGE<br />

MEETING ROOMS<br />

MAIL, COURIER & PRINT CENTRE<br />

PLANNING DEPARTMENT<br />

PURCHASING DEPARTMENT<br />

CENTRAL SERVICES<br />

BUILDING SERVICES<br />

STORAGE - MISC.<br />

LEARNING RESOURCE CENTRE<br />

GENERAL OFFICE - VARIOUS DEPARTMENTS<br />

WAREHOUSE & ARCHIVAL STORAGE<br />

CAFETERIA<br />

WORK ROOM<br />

WASHROOMS<br />

CIRCULATION<br />

COMMUNITY USE<br />

REPURPOSED / SPECIALIZED SCHOOL<br />

SECURE<br />

FILES<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-17


Proposed TASSS Re-purposing<br />

Basement plan<br />

ICT DEPARTMENT<br />

FACILITIES SERVICES OFFICES<br />

FACILITIES SERVICES MAINT. SHOPS<br />

LEADERSHIP & DEVELOPMENT<br />

TEACHING & LEARNING<br />

FINANCE DEPARTMENT<br />

MEETING ROOMS<br />

MAIL, COURIER & PRINT CENTRE<br />

PLANNING DEPARTMENT<br />

PURCHASING DEPARTMENT<br />

CENTRAL SERVICES<br />

BUILDING SERVICES<br />

STORAGE - MISC.<br />

LEARNING RESOURCE CENTRE<br />

DIRECTOR’S SUITE<br />

DIRECTOR’S SECURE RECORDS<br />

SENIOR ADMINISTRATION<br />

HUMAN RESOURCES<br />

HUMAN RESOURCES SECURE RECORDS<br />

BOARD ROOM & TRUSTEES<br />

GENERAL OFFICE - VARIOUS DEPARTMENTS<br />

WAREHOUSE & ARCHIVAL STORAGE<br />

CAFETERIA<br />

WORK ROOM<br />

WASHROOMS<br />

CIRCULATION<br />

COMMUNITY USE<br />

REPURPOSED / SPECIALIZED SCHOOL<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-18


Proposed TASSS Re-purposing<br />

Open office concept option 1<br />

ELEV.<br />

COAT<br />

CLOSET<br />

GUEST<br />

WAITING<br />

AREA<br />

LEADERSHIP<br />

&<br />

DEVELOPMENT<br />

(TRAINING ROOM)<br />

OFFICE<br />

WORK<br />

COUNTER<br />

W/ FILING<br />

CABINETS<br />

HEADS DOWN<br />

LAYOUT<br />

COLLABORATION<br />

AREA<br />

STORAGE<br />

STANDARD<br />

WORKSTATION<br />

(6’ x 8’)<br />

TEAM LAYOUT<br />

LARGE<br />

WORKSTATION<br />

(12’ x 8’)<br />

DIRECTOR OF<br />

EMPLOYEE SERVICE<br />

SECURE<br />

H.R. FILES<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-19


Proposed TASSS Re-purposing<br />

Open office concept option 2<br />

ELEV.<br />

COAT<br />

CLOSET<br />

GUEST<br />

WAITING<br />

AREA<br />

LEADERSHIP<br />

&<br />

DEVELOPMENT<br />

(TRAINING ROOM)<br />

OFFICE<br />

WORK<br />

COUNTER<br />

W/ FILING<br />

CABINETS<br />

HEADS DOWN<br />

LAYOUT<br />

ASSISTANT<br />

COLLABORATION<br />

AREA<br />

STORAGE<br />

LOW<br />

FILING<br />

GUEST<br />

WAITING<br />

AREA<br />

TEAM LAYOUT<br />

DIRECTOR OF<br />

EMPLOYEE SERVICE<br />

SECURE<br />

H.R. FILES<br />

LARGE<br />

WORKSTATION<br />

(12’ x 8’)<br />

STANDARD<br />

WORKSTATION<br />

(6’ x 8’)<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | 20


Proposed TASSS Re-purposing<br />

Vignettes<br />

AERIAL VIEW<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-21


Proposed TASSS Re-purposing<br />

Vignettes<br />

FRONT ENTRANCE VIEW - 1<br />

FRONT ENTRANCE VIEW - 2<br />

PARKING<br />

REAR VIEW<br />

ZAS ARCHITECTS INC.<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | A-22


B. Photographs<br />

Existing Education Centre Interior Images<br />

Existing TASSS Exterior Images<br />

Existing TASSS Interior Images<br />

Existing EC Shelving<br />

Existing EC Transformer<br />

Existing EC IT Equipment<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre


PHOTOGRAPHS<br />

Existing Education Centre Interior Images<br />

BACK UP POWER<br />

BOARDROOM<br />

BREAKER PANEL<br />

MAINTENANCE SHELVES<br />

ZAS ARCHITECTS INC.<br />

FEASIBILITY STUDY FOR THE KAWARTHA PINE RIDGE DISTRICT SCHOOL BOARD EDUCATION CENTRE | B-1


PHOTOGRAPHS<br />

Existing Education Centre Interior Images<br />

MOVABLE SHELVES<br />

SHOP EQUIPMENT<br />

ZAS ARCHITECTS INC.<br />

FEASIBILITY STUDY FOR THE KAWARTHA PINE RIDGE DISTRICT SCHOOL BOARD EDUCATION CENTRE | B-2


PHOTOGRAPHS<br />

Existing TASSS Exterior Images<br />

VIEW FROM PLAZA<br />

APPROACH TO ENTRANCE<br />

ENTRANCE PLAZA<br />

APPROACH TO ENTRANCE<br />

EXTERIOR MECHANICAL<br />

ZAS ARCHITECTS INC.<br />

FEASIBILITY STUDY FOR THE KAWARTHA PINE RIDGE DISTRICT SCHOOL BOARD EDUCATION CENTRE | B-3


PHOTOGRAPHS<br />

Existing TASSS Exterior Images<br />

ENTRANCE<br />

LOADING<br />

METAL PANELS<br />

NORTH EXIT<br />

ZAS ARCHITECTS INC.<br />

FEASIBILITY STUDY FOR THE KAWARTHA PINE RIDGE DISTRICT SCHOOL BOARD EDUCATION CENTRE | B-4


PHOTOGRAPHS<br />

Existing TASSS Exterior Images<br />

WEST PLAZA<br />

EXTERIOR SIGNAGE<br />

TENNIS COURTS<br />

SOUTH EXIT<br />

SPORTS FIELD<br />

TRANSFORMERS<br />

ZAS ARCHITECTS INC.<br />

FEASIBILITY STUDY FOR THE KAWARTHA PINE RIDGE DISTRICT SCHOOL BOARD EDUCATION CENTRE | B-5


PHOTOGRAPHS<br />

Existing TASSS Interior Images<br />

BEAM<br />

THEATRE<br />

SMALL GYMNASIUM<br />

ZAS ARCHITECTS INC.<br />

FEASIBILITY STUDY FOR THE KAWARTHA PINE RIDGE DISTRICT SCHOOL BOARD EDUCATION CENTRE | B-6


PHOTOGRAPHS<br />

Existing TASSS Interior Images<br />

GREEN HOUSE<br />

HOME EC<br />

SCHOOL ENTRANCE<br />

LARGE GYMNASIUM<br />

LIBRARY<br />

SHOP<br />

ZAS ARCHITECTS INC.<br />

FEASIBILITY STUDY FOR THE KAWARTHA PINE RIDGE DISTRICT SCHOOL BOARD EDUCATION CENTRE | B-7


PHOTOGRAPHS<br />

Existing TASSS Interior Images<br />

TEMPORARY RAMP<br />

WASHROOM<br />

WASHROOM<br />

WEIGHT ROOM<br />

ZAS ARCHITECTS INC.<br />

FEASIBILITY STUDY FOR THE KAWARTHA PINE RIDGE DISTRICT SCHOOL BOARD EDUCATION CENTRE | B-8


C. Structural Report<br />

BY HALSALL<br />

• Review of existing construction<br />

• Site Investigation of existing lateral system.<br />

• Review on the feasibility of the extent of demolition<br />

with the existing conditions.<br />

• Review of design intent with code compliance<br />

(seismic issues?)<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | C - 1


C. Structural Report | Halsall<br />

C - 2 | ZAS ARCHITECTS INC.


C. Structural Report | Halsall<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | C - 3


C - 4 | ZAS ARCHITECTS INC.


<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | C - 5


D. Mechanical & Electrical<br />

Report<br />

by Jain<br />

• Review of existing conditions<br />

• Site Investigation summary<br />

• Review on the feasibility of the proposed addition<br />

and re-purposing.<br />

• Review of design intent with code compliance<br />

• Proposed M&E System modifications<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | D - 1


D. Mechanical & Electrical Report | JAIN<br />

KAWARTHA PINE RIDGE DSB<br />

HEAD OFFICE RELOCATION<br />

Mechanical & Electrical Design Report<br />

Prepared by:<br />

Jain & Associates Ltd.<br />

2270 Argentia Road<br />

Mississauga, ON, L5N 6A6<br />

D - 2 | ZAS ARCHITECTS INC.


D. Mechanical & Electrical Report | JAIN<br />

Existing Mechanical System<br />

H.V.A.C<br />

Heating in the entire school is provided by three (3) gas-fired hot water boilers and cooling by a<br />

centrifugal chiller and cooling Tower. Boilers were installed in 1993 and chiller and cooling tower in<br />

2006. They are all working fine. There are a number of air handling units in several mechanical rooms<br />

providing cooling and heating for the entire school. The Cafeteria, Gym and Auditorium units also have<br />

heating coils. All units have chilled water coils. Except for the Cafeteria, Gym and Auditorium, heating<br />

in all other areas is provided by either hot water reheat coils in ducts or Unitrane units with hot water<br />

coils under windows in classrooms. Hot water re-heat coils in ducts provide individual room control.<br />

All heating piping is original (1967). All air handling units and exhaust fans were replaced in 2006.<br />

Exhaust has been provided from the Kitchen Hood, Welding Hood, Spray Booth, Science Rooms and<br />

Washrooms, etc. Make-Up Air Units have been provided for the Kitchen, Welding and Spray Booth<br />

Exhaust.<br />

A saw dust collector has been provided for the Wood Working Shop.<br />

There is a Building Management System to monitor and control all mechanical systems. The system is<br />

by Reliable Controls and all existing controls are pneumatic.<br />

Plumbing and Drainage<br />

Domestic hot water is provided by two gas-fired hot water boilers (installed in 2006) and one large hot<br />

water storage tank (installed in 1967). Storage tank was re-lined in 2010.<br />

All plumbing fixtures were replaced in 2006 however the plumbing piping is original and was installed in<br />

1967.<br />

There is an air compressor for the Shops.<br />

Fire-Protection<br />

_____________________________________________________________________________________________<br />

KPRDSB Head Office Relocation - M & E Design Report Page 1<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | D - 3


D. Mechanical & Electrical Report | JAIN<br />

There are sprinklers in certain areas of the school to meet specific code requirements. Generally, the<br />

school is non-sprinklered. There is no stand-pipe system.<br />

Proposed Mechanical System Modifications<br />

The existing mechanical system is generally in good condition because most of the major equipment and<br />

plumbing fixtures were replaced in 2006. We recommend that the following be considered for<br />

replacement because of their age. The Cost consultant should provide an itemized price for these items:<br />

I. Replace existing domestic hot water storage tank.<br />

II. Replace all existing domestic hot water piping.<br />

III. Replace all existing hot water & chilled water piping.<br />

The following work shall be done to accommodate the proposed architectural changes:<br />

I. All ductwork will be revised to suit new layout except for in the Gymnasiums, Auditorium,<br />

Cafeteria, Shops and Science Rooms/Computer Labs Wing.<br />

II. All areas were the ductwork us revised will have VAV Boxes for individual room control. For<br />

costing purposes, allow 120 VAV boxes. All VAV Boxes will have hot water reheat coils.<br />

Existing hot water piping will be adjusted to suit.<br />

III. Provide variable frequency drives on all fans in air handling units which are connected to VAV<br />

Boxes.<br />

IV. Revise all controls to electronic and provide new controls for VAV Boxes and control of VFD’s,<br />

etc.<br />

V. Provide a new sprinkler system for the entire building.<br />

Also, an Existing Liebert A.C. unit will be relocated to this building and installed in the new Server<br />

Room.<br />

Existing Electrical System<br />

Power Distribution<br />

_____________________________________________________________________________________________<br />

KPRDSB Head Office Relocation - M & E Design Report Page 2<br />

D - 4 | ZAS ARCHITECTS INC.


D. Mechanical & Electrical Report | JAIN<br />

The electrical service consists of a padmount transformer feeding switchgear in the basement electrical<br />

room which distributes power at 208V throughout the school. Panelboards are located throughout<br />

including corridors. Only the Physics lab has a dedicated panel.<br />

The existing power distribution system appears to be in good condition. The Chief Caretaker advised that<br />

the system was upgraded in approximately 2009 by Black & MacDonald. Certain components were also<br />

replaced as part of the 2006 renovation.<br />

Emergency Power& Lighting<br />

Emergency power is provided to the school via a 50 kW, 120/208V Detroit Diesel Generator that was<br />

replaced in 2006. The Head Caretaker advised that the generator is tested regularly.<br />

The generator supplies power to emergency lighting throughout the school. Only one battery unit c/w<br />

emergency lighting heads was found in the main mechanical room.<br />

Exit signs coverage appears adequate and signs are of LED technology.<br />

Lighting<br />

Interior lighting generally consists of T8 fluorescent luminaires. Fixtures are in good condition except<br />

those in the library have some discoloured lenses. It was noted that lamps in cove fixtures in corridors do<br />

not have polycarbonate lamp sleeves which is normally recommended for safety.<br />

Chief Caretaker advised that Auditorium lighting has been replaced with LED Fixtures.<br />

Lighting control consists of lighting switches and/or breaker control. Lighting is also interconnected with<br />

Intrusion Alarm system and is set to shut-off 15 minutes after system is armed.<br />

The exterior of the building is illuminated via pole-mounted metal-halide fixtures and a few wallpaks.<br />

Exterior lighting is controlled via photocell and also connected to the Intrusion Alarm System.<br />

Fire Alarm System<br />

The fire alarm control panel is located in the Chief’s Caretaker’s Office and was replaced in 1995. It is a<br />

Simplex 4100 addressable, single-stage system. Smoke and heat detectors were found throughout the<br />

buildingas required by code. Pull stations are located at exits however are not at barrier-free height.<br />

Audible devices consist of horns without visual signaling except in Mechanical Room and Shop Areas<br />

where strobes have been provided due to high ambient noise.<br />

_____________________________________________________________________________________________<br />

KPRDSB Head Office Relocation - M & E Design Report Page 3<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | D - 5


D. Mechanical & Electrical Report | JAIN<br />

There is a fire alarm annunciator in the General Office and active fire alarm graphic located outside the<br />

office.<br />

Public Address System<br />

The head-end of the public address system is located in an IT Room in the General Office Area.It is a<br />

Dukane MCS350 System. PA Speakers are located throughout the school including classrooms.<br />

Telephone handsets in the classrooms are integrated with the PA System.<br />

Other Systems<br />

There is a Simplex Central Clock System in the <strong>School</strong>. Most but not all clocks are connected to this<br />

system<br />

Many classrooms are equipped with Smartboards and ceiling-mounted projectors.<br />

Telephone cabling terminates at a phone system in a storage room adjacent to the Teacher’s Lounge.<br />

Data cabling terminates at 3 locations throughout the school.<br />

There are door contacts at exterior doors connected to a Security Panel located in the basement storage room.<br />

Proposed Electrical System Modifications<br />

Power Distribution<br />

The existing power distribution system is adequate to serve the proposed use of the building.<br />

Receptacles will need to be relocated/added to suit proposed usage of the various rooms.<br />

The Owner would like to relocate existing backup power supply (assumed to be a UPS) to this building. The<br />

system will need to be installed and wired to back up critical computer equipment.<br />

It is proposed to relocate the padmount transformer. Existing primary and secondary ductbanks c/w wiring<br />

will need to be relocated to suit.<br />

Lighting<br />

_____________________________________________________________________________________________<br />

KPRDSB Head Office Relocation - M & E Design Report Page 4<br />

D - 6 | ZAS ARCHITECTS INC.


D. Mechanical & Electrical Report | JAIN<br />

Discoloured lenses on recessed lighting fixtures should be replaced.<br />

Lighting in the main office areas should be upgraded to direct/indirect fixtures to improve aesthetics and<br />

uniformity of lighting.<br />

Occupancy sensors should be provided in enclosed rooms (office, storage rooms, washrooms, etc.) as per<br />

current energy-efficiency standards.<br />

Fire Alarm<br />

Existing fire alarm pull stations should be lowered to barrier-free height. Fire alarm strobes should also be<br />

added to meet current barrier-free standards.<br />

Other<br />

Any voice/data outlets will need to be relocated/added to suit proposed usage of the various rooms.<br />

_____________________________________________________________________________________________<br />

KPRDSB Head Office Relocation - M & E Design Report Page 5<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | D - 7


E. Code Report<br />

by Larden-Muniak<br />

• Review of existing conditions<br />

• Summary of changed use requirements<br />

• Recommended fire separation requirements<br />

• Recommended accessibility requirements<br />

• Review of design intent with code compliance<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | E - 1


E. Code Report | Larden-Muniak<br />

E - 2 | ZAS ARCHITECTS INC.


E. Code Report | Larden-Muniak<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | E - 3


E. Code Report | Larden-Muniak<br />

E - 4 | ZAS ARCHITECTS INC.


E. Code Report | Larden-Muniak<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | E - 5


E. Code Report | Larden-Muniak<br />

E - 6 | ZAS ARCHITECTS INC.


E. Code Report | Larden-Muniak<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | E - 7


E. Code Report | Larden-Muniak<br />

E - 8 | ZAS ARCHITECTS INC.


E. Code Report | Larden-Muniak<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | E - 9


E. Code Report | Larden-Muniak<br />

E - 10 | ZAS ARCHITECTS INC.


<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | E - 11


F. Cost Report<br />

BY AW Hooker<br />

<strong>Feasibility</strong> <strong>Study</strong> for the KAWartha PINE RIDGE DISTRICT SCHOOL BOARD Education Centre | F - 1


F. Cost Report | A.W Hooker<br />

PROBABLE COSTS - ORDER OF MAGNITUDE ESTIMATE SUMMARY<br />

KPRDSB FEASIBILITY STUDY<br />

September 16, 2011<br />

Life Cycle Building Costs<br />

Asbestos Abatement<br />

EDUCATION CENTRE COMMUNITY USE RE-PURPOSED SCHOOL Notes<br />

(Asbestos abated to areas identified as confirmed and presumed<br />

asbestos as per Pinchin HMIS Report)<br />

INC.DRAFT<br />

1. Setup including 200+ Type 2 enclosures, air monitoring during<br />

$313,354 $144,402 $142,244<br />

abatement and upon completion and final cleain-up in areas of<br />

enclosure<br />

2. Removal of asbestos contaminated material including disposal<br />

$360,357 $166,062 $163,581<br />

(fireproofing, tar paper, transite, VAT, gypsum board walls and<br />

ceilings, pipe fittings, etc.)<br />

Accessibility Upgrades<br />

1. New elevators in existing building (including demolition, new<br />

$375,000 $125,000<br />

foundations, new elevators, 3 stops)<br />

2. Modify existing washrooms $125,000 $25,000<br />

3. New washrooms $50,000 $50,000<br />

4. Relocate partition, door and frame for accessible clearance at<br />

$30,000<br />

alcoves<br />

5. Allowance to modify existing ramps $34,250 $15,750<br />

6. Accessible entrance at ground floor (at existing loading dock<br />

location)<br />

Mechanical Upgrades<br />

2. Replace all domestic hot water piping including insulation $105,300 $48,525 $47,800<br />

3. Replace all existing hot water and chilled water piping including<br />

$368,550 $169,838 $167,300<br />

insulation<br />

4. Provide new sprinkler system $315,900 $145,575 $143,400<br />

Note: Ductwork, VAV, control costs included with Renovation<br />

Costs (below)<br />

Electrical Upgrades<br />

1. Relocate UPS - assume 15KVA UPS $7,000<br />

2. Clean, relamp and replace lense for recessed fluorescent fixtures $31,590 $14,558 $14,340<br />

3. Provide occupancy sensors to rooms $31,590 $14,558 $14,340<br />

4. Lower pullstations, add strobe light and interface for sprinkler $52,650 $24,263 $23,900<br />

Architectural Upgrades<br />

1. Cleaning and re-painting of metal panels $50,000<br />

2. Repointing of 15% of masonry veneer (includes repointing,<br />

scaffolding or scissor lift rental. Does not include temporary heat -<br />

assumes work to be done in non-winter months.).<br />

Renovation Costs<br />

Renovations to Ground, Second and Third Floors<br />

1. Building renovations including demolition, partitions, doors,<br />

finishes, M&E services including VAV boxes, direct/indirect office<br />

lighting, etc.<br />

2. Remedial works related to removal of asbestos including<br />

$500,000<br />

replacement of removed materials (reinstate fireproofing, new<br />

VAT, gypsum board, etc.)<br />

3. Admin. Office Link addition at second floor $1,017,000<br />

4. Ground floor addition (under new admin. office link) $210,000<br />

5. New entrance canopies $540,000 $60,000 $11,000<br />

6. New building signage & wayfinding $25,000 $12,500 $12,500<br />

Relocation Costs<br />

Relocation Costs<br />

1. Complete Relocation of HD Shelving, Offices, Archives, etc. (as<br />

$290,000<br />

per AMJ Campbell Office Movers quote to KPRDSB dated 06-<br />

Sep-2011)<br />

2. Backup power, fire suppression, IT equipment and server (refer to<br />

M&E Estimate above)<br />

Site Costs<br />

Site Option 3<br />

1. Site preparation including clear and grub, demolition, grading, etc. $161,409<br />

2. Heavy duty asphalt paving $164,930<br />

3. Medium duty asphalt paving $317,135<br />

4. Concrete curbs $46,080<br />

5. Re-stripe existing and new parking $10,000<br />

6. Electrical site services $60,000<br />

7. Mechanical site services $160,000<br />

Subtotal (current dollars)<br />

$15,040,356 $816,029 $970,405<br />

1. General Requirements, Overhead and Profit (9%) $1,353,632 $73,443 $87,336<br />

2. Design Contingency (10%) $1,639,399 $88,947 $105,774<br />

F - 2 | ZAS ARCHITECTS<br />

3. Escalation and Post Contract Contingency Excluded Excluded Excluded<br />

Total Probable Costs<br />

$18,033,387 $978,418 $1,163,516<br />

Consultant Fees<br />

Consultant Fees:<br />

7.5 % of Total Construction Cost<br />

Includes Architectural, Structural, Mechanical, Electrical and IT<br />

Consultants<br />

- Traffic Consultant<br />

- Civil / Stormwater Consultant<br />

- Hazardous Materials Consultant<br />

- Building Permit Fee<br />

- Demolition Permit Fee<br />

- Hazardous Materials Removal Fee<br />

- Site Plan Approval Fee<br />

- ORCA Stormwater Management Review Fee<br />

$50,000 Required as barrier-free accessible<br />

entrance for Education Centre.<br />

1. Replace existing domestic hot water storage tank $5,000 Required base building cost (all<br />

three proposed uses).<br />

$312,761 Does not include for cleaning of<br />

entire masonry area (area not<br />

repointed).<br />

$8,950,500 Assumes re-use of existing<br />

Education Centre furniture and<br />

equipment - does not include for<br />

any new furniture and equipment.<br />

Site Option 3 required to meet<br />

parking requirements for any of the<br />

three proposed uses.<br />

This estimate does not allow for all consultant and development fees including, but not limited to: