Power distribution components<br />
3+3 Raceway<br />
six circuit, ten-wire raceway for desk supports<br />
connectors and jumpers<br />
Morrison<br />
description type w d h pattern no. list price<br />
Power connector Straight/L 18 2 2 MR3-TPCM $111.<br />
Crossover 24 2 2 MR3-TJ6 111.<br />
Panel/desk 36 2 3 MR3-NTPD 366.<br />
Jumper 12 end panel 30 2 2 MR3-TJ12 118.<br />
18 end panel 36 2 2 MR3-TJ18 125.<br />
24 desk 42 2 2 MR3-TJ24 137.<br />
24 end panel 42 2 2 MR3-TJ24 137.<br />
30 desk 48 2 2 MR3-TJ30 143.<br />
36 desk 54 2 2 MR3-TJ36 150.<br />
42 desk 60 2 2 MR3-TJ42 166.<br />
48 desk 66 2 2 MR3-TJ48 180.<br />
54 desk 75 2 2 MR3-TJ54P 193.<br />
60 desk 81 2 2 MR3-TJ60P 200.<br />
66 desk 87 2 2 MR3-TJ66P 206.<br />
72 desk 93 2 2 MR3-TJ72P 213.<br />
78 desk 99 2 2 MR3-TJ78P 220.<br />
Worksurface Planning<br />
Order Code<br />
Example: MR3-TJ12<br />
MR3 Morrison raceway<br />
T Tenwire3+3jumper<br />
J Jumper<br />
12 For 12 end panel<br />
Specification Information<br />
Morrison 3 +3 Raceway is a<br />
six-circuit, ten-wire modular power<br />
distribution system, for use in<br />
Morrison panels and Network desk<br />
supports.3+3Raceway<br />
components distribute three 20-amp<br />
convenience circuits (A, B, C), with<br />
neutral and ground, and three<br />
protected 20-amp circuits (X, Y, Z)<br />
with separate neutral and ground.<br />
171<br />
Application Notes<br />
Power connectors transmit power<br />
between adjacent powered desks.<br />
Crossover transmits power<br />
‘‘diagonally’’ between non-adjacent<br />
desks in a cluster of 3 or 4 desk<br />
supports.<br />
Jumpers connect rails on either side<br />
of a desk end panel or desk support<br />
without outlets.<br />
Power connectors and jumpers are<br />
enclosed in steel flexible conduit.