Cascade edge worksurfaces<br />

Wave End<br />

Morrison<br />

description 1 2 3 A B h pattern no. solid woodgrain<br />

Wave End, RH 36 30 24 3 15 1 1 /8 MCE1W362430N $573. $659.<br />

42 30 24 9 15 1 1 /8 MCE1W422430N 602. 693.<br />

48 30 24 15 15 1 1 /8 MCE1W482430N 645. 742.<br />

72 30 24 30 1 /2 23 1 /2 1 1 /8 MCE1W722430N 821. 942.<br />

Wave End, LH 36 24 30 15 3 1 1 /8 MCE1W363024N 573. 659.<br />

42 24 30 15 9 1 1 /8 MCE1W423024N 602. 693.<br />

48 24 30 15 15 1 1 /8 MCE1W483024N 645. 742.<br />

78 24 30 23 1 /2 30 1 /2 1 1 /8 MCE1W723024N 821. 942.<br />

Worksurface Planning<br />

Order Code<br />

Example: MCE1W483024N-118<br />

MCE1 Cascade edge<br />

worksurface<br />

W Wave end<br />

48 Width<br />

30 Depth left<br />

24 Depth right<br />

N No Grommet<br />

118 Surface finish<br />

Specification Information<br />

Specify:<br />

Grommet / no grommet.<br />

Replace the ‘‘N’’ suffix from the<br />

pattern number with ‘‘G’’. Add $20.<br />

Finish:<br />

Solid:<br />

114 Folkstone Grey<br />

117 Soft Grey<br />

118 Bright White<br />

119 Pumice<br />

Woodgrain:<br />

124 Medium Cherry<br />

125 Natural Maple<br />

126 Natural Cherry<br />

127 Walnut<br />

149<br />

Application Notes<br />

Cascade Edge worksurfaces are<br />

wrapped with a pvc free, 3D<br />

laminate sheet heated and pressed<br />

around an FSC certified substrate.<br />

3D laminate is more susceptible to<br />

denting, impact, tearing and<br />

marring than conventional high<br />

pressure laminate and should be<br />

handled with care. Do not drag<br />

worksurfaces across any flooring<br />

surface. Treat Cascade Edge<br />

worksurfaces like veneer<br />

worksurfaces for optimum<br />

performance under normal<br />

conditions. Cascade Edge<br />

worksurfaces have a 10 year<br />

warranty that covers defects in<br />

workmanship and materials. This<br />

warranty does not cover damage<br />

occurring during or after<br />

installation.<br />

Cascade Edge worksurfaces are not<br />

drilled for wire management clips,<br />

pedestals or brackets.<br />

Cascade Edge worksurfaces are for<br />

panel-based planning only and<br />

cannot be used in conjunction with<br />

Network desk supports.<br />

Worksurfaces are 1 /16 less than<br />

nominal width and 3 /8 less than<br />

nominal depth for rear wire<br />

clearance.<br />

Edge grommets are centered at rear<br />

edge of worksurface for maximun<br />

clearance of 1 3 /8<br />

Worksurfaces require support every<br />

48 in width. All supporting<br />

hardware is ordered separately.<br />

Worksurfaces may be supported at<br />

each end by pedestals or end<br />

support ‘‘EC’’ brackets and<br />

cantilever brackets matching the<br />

worksurface depth. Use cantilever<br />

bridging bracket to join to adjacent<br />

worksurface.<br />

Panel supported worksurfaces over<br />

48 must be mid-span supported by<br />

cantilever brackets, specified<br />

separately.<br />

Order Morrison brackets with wood<br />

screws ( suffix -W ).