23.03.2014 Views

download - Knoll

download - Knoll

download - Knoll

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Cascade edge worksurfaces<br />

Blended ‘‘D’’<br />

Morrison<br />

description A B C h pattern no. solid woodgrain<br />

Blended ‘‘D’’<br />

right hand shown<br />

66 48 24 1 1 /8 MCE1BD6648S(L/R) $863. $992.<br />

66 48 30 1 1 /8 MCE1BD6648D(L/R) 907. 1,044.<br />

72 48 24 1 1 /8 MCE1BD7248S(L/R) 882. 1,016.<br />

72 48 30 1 1 /8 MCE1BD7248D(L/R) 940. 1,082.<br />

78 48 24 1 1 /8 MCE1BD7848S(L/R) 1,019. 1,172.<br />

78 48 30 1 1 /8 MCE1BD7848D(L/R) 1,054. 1,211.<br />

84 48 24 1 1 /8 MCE1BD8448S(L/R) 1,047. 1,204.<br />

84 48 30 1 1 /8 MCE1BD8448D(L/R) 1,113. 1,279.<br />

Order Code<br />

Specification Information<br />

Application Notes<br />

Example: MCE1BD7248SL-118<br />

MCE1 Cascade edge<br />

worksurface<br />

BD Blended ‘‘D’’<br />

72 Width<br />

48 Depth<br />

S 24d return<br />

L Extended left<br />

118 Surface finish<br />

Finish:<br />

Solid:<br />

114 Folkstone Grey<br />

117 Soft Grey<br />

118 Bright White<br />

119 Pumice<br />

Woodgrain:<br />

124 Medium Cherry<br />

125 Natural Maple<br />

126 Natural Cherry<br />

127 Walnut<br />

Cascade Edge worksurfaces are<br />

wrapped with a pvc free, 3D<br />

laminate sheet heated and pressed<br />

around an FSC certified substrate.<br />

3D laminate is more susceptible to<br />

denting, impact, tearing and<br />

marring than conventional high<br />

pressure laminate and should be<br />

handled with care. Do not drag<br />

worksurfaces across any flooring<br />

surface. Treat Cascade Edge<br />

worksurfaces like veneer<br />

worksurfaces for optimum<br />

performance under normal<br />

conditions. Cascade Edge<br />

worksurfaces have a 10 year<br />

warranty that covers defects in<br />

workmanship and materials. This<br />

warranty does not cover damage<br />

occurring during or after<br />

installation.<br />

Worksurfaces are 1 /16 less than<br />

nominal width and 3 /8 less than<br />

moninal depth for rear wire<br />

clearance.<br />

Edge grommets are centered at rear<br />

edge of worksurface for maximun<br />

clearance of 1 3 /8<br />

Worksurfaces require support every<br />

48 in width. All support hardward<br />

is ordered separately.<br />

Blended-D worksurfaces are<br />

supported by a 48 VDT support<br />

bracket kit in conjunction with a<br />

rounded end support column. Use<br />

flat bracket or bridging bracket to<br />

join to adjacent worksurface.<br />

Order Morrison brackets with wood<br />

screws (suffix -W).<br />

Cascade Edge are not drilled for<br />

wire management clips, pedestals or<br />

brackets.<br />

Cascade Edge worksurfaces are for<br />

panel-based planning only and<br />

cannot be used in conjunction with<br />

Network desk supports.<br />

144

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!