23.03.2014 Views

Knauf Free-Spanning Ceiling D131

Knauf Free-Spanning Ceiling D131

Knauf Free-Spanning Ceiling D131

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Knauf</strong> <strong>Free</strong>-<strong>Spanning</strong> <strong>Ceiling</strong><br />

Fire protection from below / from below and from above (plenum)<br />

<strong>Ceiling</strong>s that are fire protection rated on its own<br />

Requirement to the basic ceiling<br />

for fire protection:<br />

from below<br />

no fire protection requirements<br />

to basic ceiling / roof construction<br />

from above (plenum)<br />

the basic ceiling should have<br />

the same fire protection rate<br />

as the underceiling<br />

Fire protection<br />

rate for<br />

fire stress from<br />

below<br />

above<br />

<strong>Knauf</strong> System Constructions<br />

cladding<br />

minimum<br />

thick-<br />

ness<br />

type/<br />

building<br />

material<br />

class<br />

mm<br />

metal<br />

grid<br />

max. spacing<br />

of C profiles<br />

b<br />

mm<br />

insulation<br />

(required<br />

for fire protection)<br />

min.<br />

thickness<br />

mm<br />

minimum<br />

density<br />

kg/m³<br />

<strong>D131</strong><br />

Proof<br />

<strong>D131</strong> <strong>Free</strong>-<strong>Spanning</strong> <strong>Ceiling</strong><br />

solely from below<br />

18 625<br />

mineral wool<br />

40 -<br />

G<br />

F30<br />

Fire-Resistant<br />

Boards<br />

GKF, A2<br />

25 625<br />

without insulation<br />

or<br />

min. B2<br />

ABP<br />

P-3964/2172<br />

2x 12.5 500<br />

<strong>D131</strong> <strong>Free</strong>-<strong>Spanning</strong> <strong>Ceiling</strong><br />

solely from below and from above<br />

cover strips GKF 25 mm<br />

F30<br />

F30<br />

Fire-Resistant<br />

Boards 18 625<br />

GKF, A2<br />

mineral wool S<br />

40 40<br />

or<br />

60 30<br />

ABP<br />

P-3964/2172<br />

cover strips GKF 25 mm<br />

F30<br />

F30<br />

Fire-Resistant 18<br />

Boards + 625<br />

GKF, A2 12.5<br />

covering layer<br />

without insulation<br />

or<br />

min. B2<br />

ABP<br />

P-3964/2172<br />

Flanking components should have a fire protection rate of F30.<br />

Mineral wool insulation according to DIN EN 13162, chapter 3.1.1<br />

building material class A<br />

S melting point 1000° C, G building material class A<br />

according to DIN 4102-17<br />

2<br />

Note <strong>Free</strong>-<strong>Spanning</strong> Fireboard <strong>Ceiling</strong> A1: F90 solely from below; F90 solely from below and from above - see TDS K219