Ordinary Meeting <str<strong>on</strong>g>of</str<strong>on</strong>g> Council - <strong>26</strong> April <strong>2005</strong> 21 / 64<br />

<strong>26</strong> <str<strong>on</strong>g>to</str<strong>on</strong>g> 30 Marian Street, Killara<br />

Item 21<br />

DA1243/04<br />

18 April <strong>2005</strong><br />

<strong>at</strong>tached from a suitably qualified pers<strong>on</strong> <str<strong>on</strong>g>to</str<strong>on</strong>g> the effect th<strong>at</strong> the design or m<strong>at</strong>ter complies with<br />

the relevant design Standard or Code which the Certific<strong>at</strong>e must identify.<br />

a. Details prepared by a practicing structural engineer for all or any reinforced c<strong>on</strong>crete,<br />

structural steel or tim<str<strong>on</strong>g>be</str<strong>on</strong>g>r framing.<br />

b. Wind bracing details complying with AS 1684-1992 N<strong>at</strong>i<strong>on</strong>al Tim<str<strong>on</strong>g>be</str<strong>on</strong>g>r Framing Code,<br />

AS 1170.2-1989 Wind Load Code or AS 4055-1992 Wind Loads for Housing Code.<br />

c. Retaining walls and associ<strong>at</strong>ed drainage.<br />

d. Wet area w<strong>at</strong>erpro<str<strong>on</strong>g>of</str<strong>on</strong>g>ing details complying with the Building Code <str<strong>on</strong>g>of</str<strong>on</strong>g> Australia.<br />

e. Mechanical ventil<strong>at</strong>i<strong>on</strong> details complying with Australian Standard 1668-1993<br />

Mechanical Ventil<strong>at</strong>i<strong>on</strong> & Airc<strong>on</strong>diti<strong>on</strong>ing.<br />

f. Glazing details complying with AS 1288-1989 Glass in Buildings and Install<strong>at</strong>i<strong>on</strong> Code.<br />

g. S<str<strong>on</strong>g>to</str<strong>on</strong>g>rmw<strong>at</strong>er disposal details complying with Council's S<str<strong>on</strong>g>to</str<strong>on</strong>g>rmw<strong>at</strong>er Management Manual<br />

and/or other c<strong>on</strong>diti<strong>on</strong>s <str<strong>on</strong>g>of</str<strong>on</strong>g> this c<strong>on</strong>sent.<br />

127. To ensure compliance with this determin<strong>at</strong>i<strong>on</strong> the building shall <str<strong>on</strong>g>be</str<strong>on</strong>g> set out by a Registered<br />

Surveyor and the Survey Report shall <str<strong>on</strong>g>be</str<strong>on</strong>g> lodged with the Principal Certifying Authority prior<br />

<str<strong>on</strong>g>to</str<strong>on</strong>g> the external wall c<strong>on</strong>structi<strong>on</strong> proceeding above floor level.<br />

128. For the purpose <str<strong>on</strong>g>of</str<strong>on</strong>g> safety and c<strong>on</strong>venience a balustrade <str<strong>on</strong>g>of</str<strong>on</strong>g> 1.0 metre minimum height shall <str<strong>on</strong>g>be</str<strong>on</strong>g><br />

provided <str<strong>on</strong>g>to</str<strong>on</strong>g> any landing, verandah, balc<strong>on</strong>y or stairway <str<strong>on</strong>g>of</str<strong>on</strong>g> a height exceeding 1.0 metre above<br />

finished ground level. The design may c<strong>on</strong>sist <str<strong>on</strong>g>of</str<strong>on</strong>g> vertical or horiz<strong>on</strong>tal bars but shall not have<br />

any opening exceeding 125mm. For floors more than 4.0 metres above the ground, any<br />

horiz<strong>on</strong>tal elements within the balustrade or other barrier <str<strong>on</strong>g>be</str<strong>on</strong>g>tween 150mm and 760mm above<br />

the floor must not facilit<strong>at</strong>e climbing.<br />

129. For the purpose <str<strong>on</strong>g>of</str<strong>on</strong>g> safe ingress and egress the stairs are <str<strong>on</strong>g>to</str<strong>on</strong>g> <str<strong>on</strong>g>be</str<strong>on</strong>g> c<strong>on</strong>structed within the following<br />

dimensi<strong>on</strong>s:<br />

Risers: Maximum 190mm Minimum 115mm<br />

Going (Treads): Maximum 355mm Minimum 240mm<br />

Note:<br />

Dimensi<strong>on</strong>s must also comply with limit<strong>at</strong>i<strong>on</strong>s <str<strong>on</strong>g>of</str<strong>on</strong>g> two (2) Risers and <strong>on</strong>e (1) going<br />

equalling a maximum 700mm or minimum 550mm. The Risers and Goings shall<br />

<str<strong>on</strong>g>be</str<strong>on</strong>g> uniform throughout the length <str<strong>on</strong>g>of</str<strong>on</strong>g> the stairway.<br />

130. For fire safety an au<str<strong>on</strong>g>to</str<strong>on</strong>g>m<strong>at</strong>ic fire detecti<strong>on</strong> and alarm system shall <str<strong>on</strong>g>be</str<strong>on</strong>g> installed throughout the<br />

dwelling in accordance with the following requirements:<br />

a. A smoke alarm system complying with Part 3.7.2 <str<strong>on</strong>g>of</str<strong>on</strong>g> the Building Code <str<strong>on</strong>g>of</str<strong>on</strong>g> Australia<br />

Housing Provisi<strong>on</strong>s; or<br />

b. Smoke alarms which:<br />

i. comply with Australian Standard 3786 or listed in the Scientific Services<br />

Labora<str<strong>on</strong>g>to</str<strong>on</strong>g>ry Register <str<strong>on</strong>g>of</str<strong>on</strong>g> Accredited Products (all accredited products should have<br />

scri<str<strong>on</strong>g>be</str<strong>on</strong>g>d <strong>on</strong> them the appropri<strong>at</strong>e accredit<strong>at</strong>i<strong>on</strong> not<strong>at</strong>i<strong>on</strong>); and<br />

ii. are c<strong>on</strong>nected <str<strong>on</strong>g>to</str<strong>on</strong>g> the mains and have a standby power supply; and<br />

N:\0504<strong>26</strong>-OMC-PR-03129-<strong>26</strong> TO 30 MARIAN STREET KI.doc/pseitz/64

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!