22.03.2014 Views

RMG 934-BM

RMG 934-BM

RMG 934-BM

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

FLAME ARRESTERS / VENTS<br />

<strong>RMG</strong> <strong>934</strong>-<strong>BM</strong><br />

40<br />

FLAME ARRESTER <strong>RMG</strong> <strong>934</strong>-<strong>BM</strong><br />

protecting system<br />

end-of-line deflagration and endurance burning<br />

flame arrester<br />

·<br />

certificate<br />

EC prototype test certificate according guideline<br />

94/9/EC with ATEX 95 and EN 12874<br />

gas/air- or vapourfair-mixtures of the explosion<br />

, groups:<br />

application<br />

•- I (methane) MESG ~ 1,14 mm<br />

•-IlA (DI<br />

MESG > 0,90 mm<br />

nom. diameter<br />

, DN40, DN50, DN65, DN 80<br />

• 1Vi', 2", 2 1 11", 3"<br />

, ISO 7005 PN 10<br />

connection<br />

material<br />

• ANSI B16.5 - 150 RF<br />

• Rp to ISO 7-1 (DIN 2999)<br />

: BSP to BS 21<br />

• NPTF to ANSI B1.20.3<br />

metal foi! element<br />

body<br />

hood<br />

; stainless steel<br />

· carbon steel, stainless steel<br />

• stainless steel<br />

painting<br />

optional


FLAME ARRESTERS / VENTS<br />

<strong>RMG</strong> <strong>934</strong>-BP<br />

FLAME ARRESTER <strong>RMG</strong> <strong>934</strong>-BP<br />

protecting system<br />

end-of-line deflagration and endurance burning<br />

flame arrester<br />

certificate<br />

; EC prototype test certificate according guideline<br />

94/9/EC with ATEX 95 and EN 12874<br />

. gas/air- or vapourfair-mixtures of the explosion<br />

groups:<br />

,<br />

application - I (methane) MESG ~ 1,14 mm<br />

-IlA (D)<br />

MESG > 0,90 mm<br />

nom. diameter<br />

ON25, ON32, ON40, ON50<br />

1",1';''',1'1,'',2''<br />

ISO 7005 PN 10<br />

ANSI B16,5 - 150 RF<br />

connection ' Rp to ISO 7-1 (DIN 2999)<br />

BSP to BS 21<br />

• NPTF to ANSI B 1.20,3<br />

material<br />

metal foil element<br />

bod Y<br />

hood<br />

: stainless steel<br />

, carbon steel, stainless steel<br />

plexiglas<br />

painting<br />

optional


<strong>RMG</strong> - GASELAN<br />

flame arrester<br />

<strong>RMG</strong> <strong>934</strong>-B-E<br />

design<br />

certificate<br />

application<br />

nom. diameter<br />

connection<br />

material<br />

end of line deflagration<br />

flame arrester<br />

EC prototype test certificate<br />

according guide line 94/9/EC<br />

with ATEX95 and EN12874<br />

gas/air- or vapour/air-mixtures<br />

of the explosion groups<br />

· I (methane) MESG ≥ 1,14 mm<br />

· IIA (D) MESG > 0,90 mm<br />

· IIB3 (C) MESG ≥ 0,65 mm<br />

· IIC (B) MESG < 0,50 mm<br />

DN25, DN32, DN40, DN50,<br />

DN65, DN80, DN100, DN125,<br />

DN150, DN200, DN250, DN300<br />

or 1“, 11/4“, 11/2“, 2“, 21/2“, 3“, 4“,<br />

5“, 6“, 8“, 10“, 12“<br />

EN 1092-1 PN10 (DIN 2632) or<br />

ANSI B16.5 - 150 RF<br />

metal foil element:<br />

stainless steel, Hastelloy<br />

body:<br />

carbon steel, stainless steel, Hastelloy<br />

hood:<br />

stainless steel<br />

painting optional<br />

MH280905WD<br />

Pros<strong>RMG</strong> <strong>934</strong>-B-E-gb<br />

<strong>RMG</strong>-GASELAN Regel + Meßtechnik GmbH Germany<br />

Tel.: (++49) 3361 356662, Fax: (++49) 3361 356836, E-Mail: fds@gaselan.de


FLAME ARRESTERS / VENTS<br />

<strong>RMG</strong> <strong>934</strong>-8-T<br />

FLAME ARRESTER <strong>RMG</strong> <strong>934</strong>-B-T<br />

protecting system<br />

• end-of-line deflagration and short time burning<br />

flame arrester<br />

~---<br />

c,--­<br />

certificate<br />

"<br />

:<br />

· EC prototype test certificate according guideline<br />

94/9/EC with ATEX 95 and EN 12874<br />

gas/air- or vapourfair-mixtures of the explosion<br />

, groups:<br />

application<br />

,•- I (methane) MESG 2: 1,14 mm<br />

-liA (D)<br />

MESG > 0,90 mm<br />

-IIB3 (C)<br />

·-IIC (B)<br />

MESG 2: 0,65 mm<br />

MESG < 0,50 mm<br />

nom. diameter<br />

,<br />

DN25, DN32, DN40, DN50, DN65, DN80, DN100,<br />

~DN125,DN150,DN200,DN250, DN300<br />

,1",1,/,',1'/2",2",2,/,",3",4",5",6",8",10",12"<br />

ISO 7005 PN 10<br />

ANSI S16.5 - 150 RF<br />

connection Rp to ISO 7-1 (DIN 2999)<br />

material<br />

· SSP to SS 21<br />

! NPTF to ANSI S1.20.3<br />

metal foil element<br />

body<br />

hood<br />

,<br />

· stainless steel, special alloy<br />

: carbon steel, stainless steel, special alloy<br />

' stainless steel<br />

j<br />

painting<br />

; optional<br />

temperature sensor<br />

, resistance thermometer with protection type<br />

- inherently safe (E Ex il<br />

- protected against explosion (E Ex d)<br />

i<br />

.........................<br />

. ,


FLAME ARRESTERS / VENTS<br />

<strong>RMG</strong> <strong>934</strong>-BP-E<br />

FLAME ARRESTER <strong>RMG</strong> <strong>934</strong>-Bp·E<br />

protecting system<br />

: end-of-line deflagration flame arrester<br />

certificate<br />

EC prototype test certificate according guideline<br />

94/9/EC with ATEX 95 and EN 12874<br />

: gas/air- or vapour/air-mixtures of the explosion<br />

: groups:<br />

application - I (methane) MESG" 1,14 mm<br />

• -IlA (D)<br />

MESG > 0.90 mm<br />

'-IIB3 (C)<br />

MESG ~ 0,65 mm<br />

· -IIC (Bl MESG < 0.50 mm<br />

nom. diameter<br />

, DN25. DN32, DN40. DN50. DN65. DN80. DN 100,<br />

DN125.DN150.DN200<br />

1",1'/..•• l'/i', 2", 2';,". 3", 4", 5", 6". 8"<br />

· ISO 7005 PN 10<br />

ANSI B16.5 - 150 RF<br />

connection ; Rp to ISO 7-1 (DIN 2999)<br />

• BSP to BS 21<br />

NPTF to ANSI B1.20.3<br />

material<br />

metal foil element<br />

bod Y<br />

hood<br />

; stainless steel, special alloy<br />

: carbon steel, stainless steel, special alloy<br />

! plexiglas<br />

painting<br />

optional


<strong>RMG</strong> - GASELAN<br />

flame arrester<br />

<strong>RMG</strong> <strong>934</strong>-BP-T<br />

design<br />

certificate<br />

application<br />

nom. diameter<br />

connection<br />

material<br />

end of line deflagration and<br />

short time burning flame arrester<br />

EC prototype test certificate<br />

according guide line 94/9/EC<br />

with ATEX95 and EN12874<br />

gas/air- or vapour/air-mixtures<br />

of the explosion groups<br />

· I (methane) MESG ≥ 1,14 mm<br />

· IIA (D) MESG > 0,90 mm<br />

· IIB3 (C) MESG ≥ 0,65 mm<br />

· IIC (B) MESG < 0,50 mm<br />

DN25, DN32, DN40, DN50,<br />

DN65, DN80, DN100,<br />

DN125, DN150, DN200 or<br />

1“, 11/4“, 11/2“, 2“, 21/2“, 3“, 4“,<br />

5“, 6“, 8“<br />

EN 1092-1 PN10 (DIN 2632) or<br />

ANSI B16.5 - 150 RF<br />

metal foil element:<br />

stainless steel<br />

temperature sensor<br />

resistance thermometer with protection type<br />

· inherently safe (EEx i)<br />

· protected against explosion (EEx d)<br />

body:<br />

carbon steel, stainless steel<br />

hood:<br />

acrylic (plexiglas)<br />

painting optional<br />

MH241104WD<br />

Pros<strong>RMG</strong> <strong>934</strong>-BP-T-gb<br />

<strong>RMG</strong>-GASELAN Regel + Meßtechnik GmbH Germany<br />

Tel.: (++49) 3361 356662, Fax: (++49) 3361 356836, E-Mail: fds@gaselan.de

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!