System Amplifier K&F TOPAS<br />
You can select the following options for every GPO:<br />
Setting Option Description<br />
always<br />
power on<br />
system ready<br />
Mute CH1<br />
Mute CH2<br />
Mute CH1+2<br />
AES-EBU/<br />
Analog<br />
PRIO-audio<br />
Please note:<br />
low / open<br />
high / closed<br />
low / open<br />
high / closed<br />
low / open<br />
high / closed<br />
low / open<br />
high / closed<br />
low / open<br />
high / closed<br />
low / open<br />
high / closed<br />
low / open<br />
high / closed<br />
low / open<br />
high / closed<br />
always 0V<br />
always 5V<br />
0 V, switched on amplifier<br />
5 V, switched on amplifier<br />
0 V, switched on amplifier signal paths ready for<br />
operation<br />
5 V, switched on amplifier signal paths ready for<br />
operation<br />
0 V, when channel 1 is muted<br />
5 V, when channel 1 is muted<br />
0 V, when channel 2 is muted<br />
5 V, when channel 2 is muted<br />
0 V, when channel 1 and 2 are muted<br />
5 V, when channel 1 and 2 are muted<br />
AES/EBU input is activated, otherwise analog input<br />
AES/EBU input is activated, otherwise analog input<br />
PRIO audio mode is activated<br />
PRIO audio mode is activated<br />
• at low/open the contact is always open<br />
• bei high/close ist der Kontakt immer geschlossen<br />