User's manual<br />

System Amplifier K&F TOPAS<br />

6.4.5 Power-On Options<br />

Menu: Setup » on/standby<br />

Under this menu item, you define the delay time for power on as well as the operating mode<br />

after connecting to the power supply.<br />

In the setting 'Delay time for switching main supply on', the delay time that the amplifier<br />

waits before switching from standby mode to operating mode is in milliseconds.<br />

If you want to switch on several devices simultaneously using one common switch, you must<br />

not exceed an inrush current of 7A to avoid overloading the mains. With this setting, you<br />

avoid an overload.<br />

With the option 'After AC powerloss', you determine if the amplifier should be in operating<br />

mode after connection to the power supply.<br />

This can be useful when the amplifier once again comes back to life after a power failure and<br />

the device should automatically switch to operating mode.<br />