20.03.2014 Views

AQUARICH (eco) - Kinetik

AQUARICH (eco) - Kinetik

AQUARICH (eco) - Kinetik

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

4 Studies on effectiveness/ Choice of methods/ Results<br />

4.1 Determination of effectiveness in-vivo by using Hydrascan ®<br />

4.1.1 Description of methods and test conditions<br />

The test for determining the moisturizing effect of <strong>AQUARICH</strong> ® was conducted on 15 persons in an<br />

independent testing institute. The test emulsion DAY 0402 (4% <strong>AQUARICH</strong> ® ) was tested against a<br />

placebo and a standard moisturizer (0.1% hyaluronic acid) to determine the moisturizing effect. The<br />

analyses were conducted on the underside of the forearm.<br />

The skin was measured with the Hydrascan ®<br />

application.<br />

at 1h, 3h, 8h and 24h intervals after the last<br />

With the specially developed Hydrascan ® method it is possible to determine the moisture in three<br />

different skin depths. The so-called “Transient Thermal Transfer“ (TTT) enables the measurement<br />

of skin moisture in the epidermis divided into three layers, the upper, middle and lower epidermis<br />

layers.<br />

The Hydrascan ® method is based on thermal conductivity and resistance which after conversion<br />

can be used for determining skin moisture exactly.<br />

The TTT measurement is<br />

based on the combination of<br />

thermal radiation/conductivity<br />

which allows conclusions to be<br />

drawn about the extent of skin<br />

moisture.<br />

The main advantage of this<br />

measuring method is that three<br />

different measuring zones can<br />

be integrated in just one<br />

measurement.<br />

The moisturizing effect of <strong>AQUARICH</strong> ® was determined in the test during 1h, 3h, 8h and 24h on 15<br />

persons.<br />

One hour before the first measurement (D0) the subjects were treated as follows:<br />

• The test persons appeared at the testing institute without pre-treatment of the arms by any<br />

applications<br />

• All subjects were informed about the exact procedure<br />

• Measurement of the zero value with Hydrascan ®<br />

• Application of a standardised amount (2μl/cm 2 ) of the test vehicle<br />

Page 11 / 26<br />

<strong>AQUARICH</strong> ®<br />

(<strong>eco</strong>) │ Moisture for Skin & Hair

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!