Ethernet Communication Module IFD9506
Ethernet Communication Module IFD9506
Ethernet Communication Module IFD9506
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Ethernet</strong> <strong>Communication</strong> <strong>Module</strong> <strong>IFD9506</strong><br />
1. Use DVPACAB2A30 cable to connect the PC and <strong>IFD9506</strong>. Open the setup page.<br />
2. Check “Factory Setting” box and the warning dialog box will appear. Click on “Yes” to return to default<br />
settings (in approx. 5 ~ 10 seconds), and the password will be cleared as well.<br />
10.3 IP Filter Protection<br />
Application<br />
Steps<br />
Setting up IP filter protection. Only connections to 192.168.0.7 and 172.16.0.1 ~<br />
172.16.0.255 are allowed.<br />
(1) Check "Enable IP Filter” box.<br />
(2) Set up IP address to “192.168.0.7” and netmask to “255.255.255.255”.<br />
(3) Set up IP addres to “172.16.0.1” and netmask to “255.255.255.0”.<br />
1. See 8.1 for the connection and how to set up the communication.<br />
2. Open the setup page and switch to “IP Filter” page.<br />
3. Check “Enable IP Filter” box. Enter “192.168.0.7” into No. 1 IP and “255.255.255.255” in all “Netmask”<br />
columns.<br />
40<br />
DVP-PLC Application Manual