6. Start Item:<br />

The start item of data. Range: 1 ~ 3<br />

7. Stop Item:<br />

The stop item of data. Range: 1 ~ 3<br />

When the start item and stop item are set, <strong>IFD9506</strong> will transmit data following the start item and<br />

stop item. If the transmission time exceeds the Modbus time-out, <strong>IFD9506</strong> will dispose of<br />

incomplete data.<br />

Note:<br />

When using two <strong>IFD9506</strong> modules as Mater and Slave and its user define functions, the settings<br />

of the fixed length, start item and stop item have to be consistent. If not, the data will be filtered<br />

automatically.<br />

10 Application Examples – DCISoft<br />

10.1 Setting up & Unlocking Password<br />

Application<br />

Steps<br />

Setting up password by <strong>IFD9506</strong> configuration<br />

(1) Set up password in <strong>IFD9506</strong>.<br />

(2) Unlock <strong>IFD9506</strong>.<br />

1. See 8.1 for the connection and how to set up the communication.<br />

2. Open the setup page and switch to “Security" page.<br />

3. Check “Modify” and enter “aabb” in “Password” and “Confirm Password” columns. Click on “OK” to save the<br />

password.<br />

38<br />