2. Programming Concepts<br />

Special<br />

D<br />

Content<br />

<strong>ES2</strong> SS<br />

<strong>EX2</strong> 2<br />

SA<br />

2<br />

SX<br />

2<br />

OFF<br />

<br />

ON<br />

STOP<br />

<br />

RUN<br />

RUN<br />

Attrib. Latch Default<br />

-ed<br />

STOP<br />

↓<br />

PLC LINK<br />

D1767*<br />

D1768*<br />

↓<br />

The data which is read from slave ID#10 in the<br />

PLC LINK<br />

○ ○ ○ ○ 0 - -<br />

D1783*<br />

R NO 0<br />

D1784*<br />

↓<br />

D1799*<br />

The data which is written into slave ID#10 in the<br />

PLC LINK<br />

○ ○ ○ ○ 0 - - R/W NO 0<br />

D1800*<br />

The data which is read from slave ID#11 in the<br />

↓<br />

PLC LINK<br />

○ ○ ○ ○ 0 - -<br />

D1815*<br />

R NO 0<br />

D1816*<br />

The data which is written into slave ID#11 in the<br />

↓<br />

PLC LINK<br />

D1831*<br />

○ ○ ○ ○ 0 - - R/W NO 0<br />

D1832*<br />

The data which is read from slave ID#12 in the<br />

↓<br />

PLC LINK<br />

○ ○ ○ ○ 0 - -<br />

D1847*<br />

R NO 0<br />

D1848*<br />

The data which is written into slave ID#12 in the<br />

↓<br />

PLC LINK<br />

D1863*<br />

○ ○ ○ ○ 0 - - R/W NO 0<br />

D1864*<br />

The data which is read from slave ID#13 in the<br />

↓<br />

PLC LINK<br />

○ ○ ○ ○ 0 - -<br />

D1879*<br />

R NO 0<br />

D1880*<br />

The data which is written into slave ID#13 in the<br />

↓<br />

PLC LINK<br />

D1895*<br />

○ ○ ○ ○ 0 - - R/W NO 0<br />

D1896*<br />

The data which is read from slave ID#14 in the<br />

↓<br />

PLC LINK<br />

○ ○ ○ ○ 0 - -<br />

D1911*<br />

R NO 0<br />

D1900*<br />

Specify the station number of Slaves for PLC-Link<br />

↓<br />

when M1356 is ON. Consecutive station numbers<br />

set by D1399 will be invalid in this case. Note that<br />

○ ╳ ○ ○<br />

D1931*<br />

the registers are latched only when M1356 is ON.<br />

0 - - R/W NO<br />

D1912*<br />

The data which is written into slave ID#14 in the<br />

↓<br />

PLC LINK<br />

D1927*<br />

○ ○ ○ ○ 0 - - R/W NO 0<br />

D1928*<br />

The data which is read from slave ID#15 in the<br />

↓<br />

PLC LINK<br />

○ ○ ○ ○ 0 - -<br />

D1943*<br />

R NO 0<br />

D1944*<br />

The data which is written into slave ID#15 in the<br />

↓<br />

PLC LINK<br />

D1959*<br />

○ ○ ○ ○ 0 - - R/W NO 0<br />