2. Programming Concepts<br />

Special<br />

D<br />

D1352<br />

Content<br />

Start/end frequency of the 2 nd group pulse output<br />

CH1 (Y2, Y3)<br />

<strong>ES2</strong> SS<br />

<strong>EX2</strong> 2<br />

SA<br />

2<br />

SX<br />

2<br />

OFF<br />

<br />

ON<br />

STOP<br />

<br />

RUN<br />

RUN<br />

Attrib. Latch<br />

-ed<br />

Default<br />

STOP<br />

○ ○ ○ ○ 100 - - R/W NO 100<br />

D1353<br />

D1354<br />

D1355*<br />

D1356*<br />

D1357*<br />

D1358*<br />

D1359*<br />

D1360*<br />

D1361*<br />

D1362*<br />

D1363*<br />

D1364*<br />

D1365*<br />

D1366*<br />

D1367*<br />

D1368*<br />

D1369*<br />

D1370*<br />

Ramp up/down time of the 2 nd group pulse<br />

output CH1 (Y2, Y3)<br />

PLC Link scan cycle (Unit: 1ms)<br />

• Max: K32000<br />

• D1354 = K0 when PLC Link stops or when the<br />

first scan is completed<br />

Starting reference for Master to read from Slave<br />

ID#1<br />

Starting reference for Master to read from Slave<br />

ID#2<br />

Starting reference for Master to read from Slave<br />

ID#3<br />

Starting reference for Master to read from Slave<br />

ID#4<br />

Starting reference for Master to read from Slave<br />

ID#5<br />

Starting reference for Master to read from Slave<br />

ID#6<br />

Starting reference for Master to read from Slave<br />

ID#7<br />

Starting reference for Master to read from Slave<br />

ID#8<br />

Starting reference for Master to read from Slave<br />

ID#9<br />

Starting reference for Master to read from Slave<br />

ID#10<br />

Starting reference for Master to read from Slave<br />

ID#11<br />

Starting reference for Master to read from Slave<br />

ID#12<br />

Starting reference for Master to read from Slave<br />

ID#13<br />

Starting reference for Master to read from Slave<br />

ID#14<br />

Starting reference for Master to read from Slave<br />

ID#15<br />

Starting reference for Master to read from Slave<br />

ID#16<br />

○ ○ ○ ○ 100 - - R/W NO 100<br />

○ ○ ○ ○ 0 0 0 R NO 0<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

○ ○ ○ ○ - - - R/W YES H’1064<br />

D1386 ID of the 1 st left side module ╳ ╳ ○ ○ 0 - - R NO 0<br />

D1387 ID of the 2 nd left side module ╳ ╳ ○ ○ 0 - - R NO 0<br />

D1388 ID of the 3 rd left side module ╳ ╳ ○ ○ 0 - - R NO 0<br />

D1389 ID of the 4 th left side module ╳ ╳ ○ ○ 0 - - R NO 0<br />

D1390 ID of the 5 th left side module ╳ ╳ ○ ○ 0 - - R NO 0<br />

D1391 ID of the 6 th left side module ╳ ╳ ○ ○ 0 - - R NO 0<br />

D1392 ID of the 7 th left side module ╳ ╳ ○ ○ 0 - - R NO 0<br />