2. Programming Concepts<br />

Special<br />

D<br />

Content<br />

<strong>ES2</strong> SS<br />

<strong>EX2</strong> 2<br />

SA<br />

2<br />

SX<br />

2<br />

OFF<br />

<br />

ON<br />

STOP<br />

<br />

RUN<br />

RUN<br />

Attrib. Latch<br />

-ed<br />

Default<br />

STOP<br />

D1187 Index register F3 ○ ○ ○ ○ 0 - - R/W NO 0<br />

D1188 Index register E4 ○ ○ ○ ○ 0 - - R/W NO 0<br />

D1189 Index register F4 ○ ○ ○ ○ 0 - - R/W NO 0<br />

D1190 Index register E5 ○ ○ ○ ○ 0 - - R/W NO 0<br />

D1191 Index register F5 ○ ○ ○ ○ 0 - - R/W NO 0<br />

D1192 Index register E6 ○ ○ ○ ○ 0 - - R/W NO 0<br />

D1193 Index register F6 ○ ○ ○ ○ 0 - - R/W NO 0<br />

D1194 Index register E7 ○ ○ ○ ○ 0 - - R/W NO 0<br />

D1195 Index register F7 ○ ○ ○ ○ 0 - - R/W NO 0<br />

D1220 Pulse output mode setting of CH0 (Y0, Y1) ○ ○ ○ ○ 0 - - R/W NO 0<br />

D1221 Pulse output mode setting of CH1 (Y2, Y3) ○ ○ ○ ○ 0 - - R/W NO 0<br />

D1232*<br />

D1233*<br />

D1234*<br />

D1235*<br />

Number of output pulses for CH0 (Y0, Y1) rampdown<br />

stop when mark sensor receives signals.<br />

(Low word).<br />

Number of output pulses for CH0 (Y0, Y1) rampdown<br />

stop when mark sensor receives signals.<br />

(High word).<br />

Number of output pulses for CH1 (Y2, Y3) rampdown<br />

stop when mark sensor receives signals.<br />

(Low word).<br />

Number of output pulses for CH2 (Y2, Y3) rampdown<br />

stop when mark sensor receives signals.<br />

(High word).<br />

○ ○ ○ ○ 0 0 -- R/W NO 0<br />

○ ○ ○ ○ 0 0 -- R/W NO 0<br />

○ ○ ○ ○ 0 0 -- R/W NO 0<br />

○ ○ ○ ○ 0 0 -- R/W NO 0<br />

D1240*<br />

D1241*<br />

D1242*<br />

D1243*<br />

D1244<br />

D1245<br />

D1249<br />

D1250<br />

D1252<br />

When interupt I400/I401/I100/I101 occurs,<br />

D1240 stores the low word of high-speed counter.<br />

When interupt I400/I401/I100/I101 occurs,<br />

D1241 stores the high Word of high-speed<br />

counter.<br />

When interupt I500/I501/I300/I301 occurs,<br />

D1242 stores the low Wordof high-speed counter.<br />

When interupt I500/I501/I300/I301 occurs, D1243<br />

stores the high Word of high-speed counter.<br />

Idle time (pulse number) setting of CH0 (Y0, Y1)<br />

The function is disabled if set value≦0.<br />

Idle time (pulse number) setting of CH1 (Y2, Y3)<br />

The function is disabled if set value≦0.<br />

Set value for COM1 (RS-232) data receiving timeout<br />

(Unit: 1ms, min. 50ms, value smaller than<br />

50ms will be regarded as 50ms) (only applicable<br />

for MODRW/RS instruction) In RS instruction, no<br />

time-out setting if “0” is specified.<br />

COM1 (RS-232) communication error code (only<br />

applicable for MODRW/RS instruction)<br />

Set value for COM3 (RS-485) data receiving timeout<br />

(Unit: 1ms, min. 50ms, value smaller than<br />

50ms will be regarded as 50ms) (only applicable<br />

for MODRW/RS instruction) In RS instruction, no<br />

time-out setting if “0” is specified<br />

○ ○ ○ ○ 0 0 - R NO 0<br />

○ ○ ○ ○ 0 0 - R NO 0<br />

○ ○ ○ ○ 0 0 - R NO 0<br />

○ ○ ○ ○ 0 0 - R NO 0<br />

○ ○ ○ ○ 0 - - R/W NO 0<br />

○ ○ ○ ○ 0 - - R/W NO 0<br />

○ ○ ○ ○ 0 - - R/W NO 0<br />

○ ○ ○ ○ 0 - - R/W NO 0<br />

○ ╳ ○ ╳ 50 - - R/W NO 50<br />

2-43