<strong>DVP</strong>-<strong>ES2</strong>/<strong>EX2</strong>/<strong>SS2</strong>/<strong>SA2</strong>/<strong>SX2</strong>/SE <strong>Operation</strong> <strong>Manual</strong> - Programming<br />

1) Users should use standard Delta cables when creating the CANopen network. These cables<br />

are the thick cable TAP-CB01, the thin cable TAP-CB02, and the thin cable TAP-CB10. The<br />

communication cables should be away from the power cables.<br />

2) TAP-TR01. CAN+ and CAN-, which are at the endpoints of the network, should be connected<br />

to 120 ohm resistors. Users can purchase the standard Delta terminal resistor TAP-TR01.<br />

3) The limitation on the length of the CANopen network<br />

The transmission distance of the CANopen network depends on the transmission rate of the<br />

CANopen network. The relation between the transmission rate and the maximum<br />

communication distance is shown in the following table.<br />

Transmission rate<br />

(bit/second)<br />

Maximum<br />

communication<br />

distance (meter)<br />

20K 50K 125K 250K 500K 1M<br />

2500 1000 500 250 100 25<br />

4) The Delta network products related to the CANopen network are listed below.<br />

Product Model Function<br />

<strong>DVP</strong>32<strong>ES2</strong>00RC<br />

<strong>DVP</strong>32<strong>ES2</strong>00TC<br />

It is a <strong>DVP</strong>-<strong>ES2</strong>-C series PLC with the<br />

built-in CAN interface. It can function as the<br />

CANopne master or slave.<br />

<strong>DVP</strong>COPM-SL<br />

<strong>DVP</strong>COPM-SL is a module connected to<br />

the left side of an S series PLC. It can<br />

function as the CANopen master or slave.<br />

The PLCs which can be connected to<br />

<strong>DVP</strong>COPM-SL are <strong>DVP</strong>-28SV, <strong>DVP</strong>-SV2,<br />

<strong>DVP</strong>-<strong>SX2</strong>, <strong>DVP</strong>-<strong>SA2</strong>, and <strong>DVP</strong>-EH2-L.<br />

IFD9503<br />

It converts CANopen to the Modbus<br />

gateway, and connects the device (with the<br />

RS-232 or RS-485 interface) which<br />

conforms to the standard Modbus protocol<br />

to the CANopen network. 15 devices at<br />

most can be connected.<br />

<strong>DVP</strong>CP02-H2<br />

It is the CANopen slave module, and is<br />

connected to the right side of an EH2<br />

series PLC. It can connect the EH2 series<br />

PLC to the CANopen network.<br />

IFD6503<br />

It is a tool used to analyze the CANopen<br />

network data. The interfaces at both ends<br />

are the CAN interface and the USB<br />

interface. It can be used to catch the CAN<br />

network data, or allow the CAN nodes to<br />

transmit the data. The product is used with<br />

the software Netview Builder.<br />

7-6