7 CANopen Function and <strong>Operation</strong><br />

Storage<br />

64-bit<br />

LINT ULINT LREAL LWORD<br />

Data type<br />

‣ If the CAN port functions as a slave, it has the following functions.<br />

It supports the standard CANopen protocol DS301 V4.02.<br />

It supports the NMT (network management object) service.<br />

It supports the NMT state control.<br />

The state of <strong>DVP</strong>-<strong>ES2</strong>-C in the CANopen network is controlled by a master.<br />

It supports the NMT error control.<br />

Heartbeat is supported, but Node Guarding is not supported.<br />

It supports the PDO (process data object) service.<br />

The PDO message is used to transmit the immediate input data and output data.<br />

It supports 8 TxPDO at most, and 8 RxPDO at most.<br />

The PDO transmission type: The synchronous mode, and the asynchronous mode<br />

It supports the service of reading the emergency from a slave.<br />

If an error or an alarm occurs in <strong>DVP</strong>-<strong>ES2</strong>-C, the master is notified through the emergency.<br />

7.1.2 The Input/Output Mapping Areas<br />

<strong>DVP</strong>-<strong>ES2</strong>-C as a master supports 16 slaves at most, and the slave node ID range from 1 to 16. The<br />

output mapping areas are D6250-D6476, and the input mapping areas are D6000-D6226.<br />

Device in the PLC<br />

D6250~D6281<br />

D6000~D6031<br />

Mapping area<br />

SDO request information, NMT service information, and<br />

Emergency request information<br />

SDO reply information, and Emergency reply<br />

information<br />

Mapping<br />

length<br />

64 bytes<br />

64 bytes<br />

D6282~D6476 RxPDO mapping area 390 bytes<br />

D6032~D6226 TxPDO mapping area 390 bytes<br />

7.2 The Installation and the Network Topology<br />

This section introduces the dimensions of <strong>DVP</strong>-<strong>ES2</strong>-C, the CAN interface, the CANopen network<br />

framework, and the communication distance.<br />

7.2.1 The Dimensions<br />

90<br />

98<br />

106<br />

110<br />

L1<br />

61.5<br />

L 78<br />

Unit: millimeter<br />

7-3