4. Communications<br />

Field name ASCII Hex<br />

Bytes Count 10 31 30<br />

Data Hi (T20) 00 30 30<br />

Data Lo (T20) 01 30 31<br />

Data Hi (T21) 00 30 30<br />

Data Lo (T21) 02 30 32<br />

Data Hi (T22) 00 30 30<br />

Data Lo (T22) 03 30 33<br />

Data Hi (T23) 00 30 30<br />

Data Lo (T23) 04 30 34<br />

Data Hi (T24) 00 30 30<br />

Data Lo (T24) 05 30 35<br />

Data Hi (T25) 00 30 30<br />

Data Lo (T25) 06 30 36<br />

Data Hi (T26) 00 30 30<br />

Data Lo (T26) 07 30 37<br />

Data Hi (T27) 00 30 30<br />

Data Lo (T27) 08 30 38<br />

Check sum(LRC) C8 43 38<br />

END CR LF 0D 0A<br />

4.2.3 LRC CHK (checksum)<br />

LRC (Longitudinal Redundancy Check) is calculated by summing up the Hex values from ADR1 to last<br />

data character then finding the 2’s-complement negation of the sum.<br />

Example: Read the content of register at address 0401H. 01H+03H+04H+01H+00+01H = 0AH.<br />

The 2’s-complement of 0AH: F6H<br />

Field name ASCII Hex<br />

STX : 3A<br />

Slave Address 01 30 31<br />

Command code 03 30 33<br />

Starting data address Hi 04 30 34<br />

Starting data address Lo 01 30 31<br />

Number of data Hi 00 30 30<br />

Number of data Lo 01 30 31<br />

LRC checksum F6 46 36<br />

END CR LF 0D 0A<br />

4-5