3. Instruction Set<br />

reset after CH0 (Y0, Y1) pulse output is completed.<br />

M1524<br />

M1534<br />

M1535<br />

Auto-reset CH1 (Y2, Y3) when high speed pulse output completed. M524 will be<br />

reset after CH1 (Y2, Y3) pulse output is completed.<br />

Enable ramp-down time setting on Y0. Has to be used with D1348<br />

Enable ramp-down time setting on Y2. Has to be used with D1349<br />

2. Special registers:<br />

D1026: Pulse number for masking Y0 when M1156 = ON (Low word). The function is<br />

disabled when set value≦0. (Default = 0 )<br />

D1027: Pulse number for masking Y0 when M1156 = ON (High word). The function is<br />

disabled when set value≦0. (Default = 0 )<br />

D1135: Pulse number for masking Y2 when M1156 = ON (Low word). The function is<br />

disabled when set value≦0. (Default = 0 )<br />

D1136: Pulse number for masking Y2 when M1156 = ON (High word). The function is<br />

disabled when set value≦0. (Default = 0 )<br />

D1030: Low word of the present value of CH0 (Y0, Y1) pulse output<br />

D1031: High word of the present value of CH0 (Y0, Y1) pulse output<br />

D1131: Input/output percentage value of CH0 (Y0, Y1) close loop control. Default: K100<br />

D1132: Input/output percentage value of CH1 (Y2, Y3) close loop control. Default: K100<br />

D1244:<br />

D1245:<br />

Idle time (pulse number) setting of CH0 (Y0, Y1) The function is disabled if set<br />

value≦0.<br />

Idle time (pulse number) setting of CH2 (Y2, Y3) The function is disabled if set<br />

value≦0.<br />

D1336: Low word of the present value of CH1 (Y2, Y3) pulse output<br />

D1337: High word of the present value of CH1 (Y2, Y3) pulse output<br />

D1340: Start/end frequency of the 1st group pulse output CH0 (Y0, Y1). Default: K100<br />

D1352: Start/end frequency of the 2st group pulse output CH1 (Y2, Y3). Default: K100<br />

D1343: Ramp up/down time of the 1st group pulse output CH0 (Y0, Y1). Default: K100<br />

D1353: Ramp up/down time of the 2nd group pulse output CH1 (Y2, Y3). Default: K100<br />

D1348: CH0(Y0, Y1) pulse output. When M1534 = ON, D1348 stores the ramp-down<br />

time. Default: K100<br />

D1349: CH1(Y2, Y3) pulse output. When M1535 = ON, D1349 stores the ramp-down<br />

time. Default: K100<br />