<strong>DVP</strong>-<strong>ES2</strong>/<strong>EX2</strong>/<strong>SS2</strong>/<strong>SA2</strong>/<strong>SX2</strong>/SE <strong>Operation</strong> <strong>Manual</strong> - Programming<br />

Special<br />

M<br />

Function<br />

OFF<br />

<strong>ES2</strong><br />

<strong>SS2</strong> <strong>SA2</strong> <strong>SX2</strong><br />

<strong>EX2</strong><br />

<br />

ON<br />

STOP<br />

<br />

RUN<br />

RUN<br />

<br />

STOP<br />

Attrib. Latch<br />

-ed<br />

Default<br />

M1233 C233 counter monitor (ON: count down) ○ ○ ○ ○ OFF - - R NO OFF<br />

M1234 C234 counter monitor (ON: count down) ○ ○ ○ ○ OFF - - R NO OFF<br />

M1235 C235 counting mode (ON: count down) ○ ○ ○ ○ OFF - - R/W NO OFF<br />

M1236 C236 counting mode (ON: count down) ○ ○ ○ ○ OFF - - R/W NO OFF<br />

M1237 C237 counting mode (ON: count down) ○ ○ ○ ○ OFF - - R/W NO OFF<br />

M1238 C238 counting mode (ON: count down) ○ ○ ○ ○ OFF - - R/W NO OFF<br />

M1239 C239 counting mode (ON: count down) ○ ○ ○ ○ OFF - - R/W NO OFF<br />

M1240 C240 counting mode (ON: count down) ○ ○ ○ ○ OFF - - R/W NO OFF<br />

M1241 C241 counting mode (ON: count down) ○ ○ ○ ○ OFF - - R/W NO OFF<br />

M1242 C242 counting mode (ON: count down) ○ ○ ○ ○ OFF - - R/W NO OFF<br />

M1243<br />

M1244<br />

C243 Reset function control. ON = R<br />

function disabled<br />

C244 Reset function control. ON = R<br />

function disabled<br />

○ ○ ○ ○ OFF - - R/W NO OFF<br />

○ ○ ○ ○ OFF - - R/W NO OFF<br />

M1245 C245 counter monitor (ON: count down) ○ ○ ○ ○ OFF - - R NO OFF<br />

M1246 C246 counter monitor (ON: count down) ○ ○ ○ ○ OFF - - R NO OFF<br />

M1247 C247 counter monitor (ON: count down) ○ ○ ○ ○ OFF - - R NO OFF<br />

M1248 C248 counter monitor (ON: count down) ○ ○ ○ ○ OFF - - R NO OFF<br />

M1249 C249 counter monitor (ON: count down) ○ ○ ○ ○ OFF - - R NO OFF<br />

M1250 C250 counter monitor (ON: count down) ○ ○ ○ ○ OFF - - R NO OFF<br />

M1251 C251 counter monitor (ON: count down) ○ ○ ○ ○ OFF - - R NO OFF<br />

M1252 C252 counter monitor (ON: count down) ○ ○ ○ ○ OFF - - R NO OFF<br />

M1253 C253 counter monitor (ON: count down) ○ ○ ○ ○ OFF - - R NO OFF<br />

M1254 C254 counter monitor (ON: count down) ○ ○ ○ ○ OFF - - R NO OFF<br />

Set the ramp up/down of Y0, Y2 to be “S<br />

M1257<br />

curve.” ON = S curve.<br />

Set up X7 as the reset signal for software<br />

M1260<br />

counters C235 ~ C241<br />

Enable cyclic output for table output<br />

M1262 function of DPTPO instruction. ON =<br />

enable.<br />

C235 counting mode (ON: falling-edge<br />

M1270<br />

count)<br />

C236 counting mode ON: falling-edge<br />

M1271<br />

count)<br />

C237 counting mode (ON: falling-edge<br />

M1272<br />

count)<br />

C238 counting mode (ON: falling-edge<br />

M1273<br />

count)<br />

○ ○ ○ ○ OFF OFF - R/W NO OFF<br />

○ ○ ○ ○ OFF - - R/W NO OFF<br />

○ ○ ○ ○ OFF OFF - R/W NO OFF<br />

○ ○ ○ ○ OFF - - R/W NO OFF<br />

○ ○ ○ ○ OFF - - R/W NO OFF<br />

○ ○ ○ ○ OFF - - R/W NO OFF<br />

○ ○ ○ ○ OFF - - R/W NO OFF<br />