17.03.2014 Views

DVP-ES2-EX2-SS2-SA2-SX2-Operation Manual

DVP-ES2-EX2-SS2-SA2-SX2-Operation Manual

DVP-ES2-EX2-SS2-SA2-SX2-Operation Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>DVP</strong>-<strong>ES2</strong>/<strong>EX2</strong>/<strong>SS2</strong>/<strong>SA2</strong>/<strong>SX2</strong> <strong>Operation</strong> <strong>Manual</strong> - Programming<br />

API Mnemonic Operands Function<br />

194 D CIMA<br />

Type<br />

2-Axis Absolute<br />

Position Arc<br />

Interpolation<br />

Controllers<br />

<strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong> <strong>SA2</strong> <strong>SX2</strong><br />

SE<br />

Bit Devices Word devices Program Steps<br />

OP X Y M S K H KnX KnY KnM KnS T C D E F<br />

S 1 * * *<br />

S 2 * * *<br />

S *<br />

D *<br />

DCIMA: 17 steps<br />

PULSE 16-bit 32-bit<br />

<strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong> <strong>SA2</strong><br />

<strong>SA2</strong><br />

<strong>SA2</strong><br />

<strong>SX2</strong> <strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong> <strong>SX2</strong> <strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong><br />

SE SE SE <strong>SX2</strong><br />

Operands:<br />

S1: Number of output pulses of X axis S2: Number of output pulses of Y axis S:<br />

Parameter setting D: Pulse output device<br />

Explanations:<br />

1. For <strong>ES2</strong>/<strong>EX2</strong> models, only V1.20 or above supports the function.<br />

2. The instruction only supports the pulse output type: Pulse / Direction.<br />

3. S 1 and S 2 specify the number of output pulses (absolute positioning) on X axis (Y0) and Y axis<br />

(Y2). Range: -2,147,483,648 ~ +2,147,483,647. When S 1 and S 2 are bigger than PV of pulse<br />

output in CH0 (D1031 High, D1030 low) / CH1 (D1337 high, D1336 low), pulse output will<br />

operate in positive direction and the direction signal output Y1, Y3 will be OFF. When S 1 and<br />

S 2 are smaller than PV of pulse output, pulse output will operate in negative direction and the<br />

direction signal output Y1, Y3 will be ON.<br />

4. For the rest of the explanations on the instruction, special D and special M, please refer to API<br />

193 DCIMR instruction.<br />

Program Example 1:<br />

1. Draw an ellipse as the figure below.<br />

Y<br />

( 16000,22000)<br />

( 0,0)<br />

( 32000,0)<br />

X<br />

(16000,-22000)<br />

2. Steps:<br />

a) Set the four coordinates (0,0), (16000, 22000), (32000, 0), (16000, -22000) (as the figure<br />