<strong>DVP</strong>-<strong>ES2</strong>/<strong>EX2</strong>/<strong>SS2</strong>/<strong>SA2</strong>/<strong>SX2</strong> <strong>Operation</strong> <strong>Manual</strong> - Programming<br />

6. Draw four 90° arcs as the figure below.<br />

When the direction signal is ON, the direction is positive(QI, QIV). When the direction signal is<br />

OFF, the direction is negative(QII, QIII). When S is set as K0, the arcs will be clockwise (see<br />

figure 3). When S is set as K, the arcs will be counterclockwise (see figure 4).<br />

Y<br />

Y<br />

Quadrant II<br />

Quadrant I<br />

Quadrant I<br />

Quadrant II<br />

X<br />

X<br />

Quadrant III<br />

Quadrant IV<br />

Quadrant III<br />

Quadrant IV<br />

Figure 3 Figure 4<br />

7. The settings of direction and resolution in the lower word of S can only be K0 ~ K1<br />

8. The settings of motion time in the high word of S shall not be faster than the fastest suggested<br />

time. If the motion time is not specified, PLC will use the fastest suggested motion time as the<br />

setting. Refer to the table below.<br />

Segments Max. target position (pulse) Fastest suggested set time (unit:100ms)<br />

500 ~ 20,000 2<br />

20-segments<br />

resolution<br />

20,000 ~ 29,999 3<br />

: :<br />

Less than 10,000,000 Less than 200<br />

9. D can designate Y0 only.<br />

Y0 is the pulse output point of X axis;<br />

Y1 is the direction signal output of X axis.(OFF: positive; ON: negative)<br />

Y2 is the pulse output point of Y axis;<br />

Y3 is the direction signal output of Y axis (OFF: positive; ON: negative)<br />

When the pulse output is completed, the direction output signal will not be OFF unless the drive<br />

contact is OFF<br />

10. When the 2-axis interpolation is being executed in 20 segments, it takes approximately 2ms for<br />

the initialization of this instruction. If only 1 axis is specified with pulse output number (with<br />

ramp-up/down section), i.e. another axis is 0, PLC will only execute single-axis positioning<br />

according to the specified motion time. If one of the two axes is specified with the pulse number<br />

less than 500, PLC will execute 2-axis linear interpolation automatically. However, when either<br />

axis is specified for pulse number over 10,000,000, the instruction will not work.<br />

11. If the number of pulses which exceeds the above range is required, the user may adjust the<br />

gear ratio of the servo for obtaining the desired results.<br />

12. Every time when the instruction is executed, only one 90° arc can be drawn. It is not necessary<br />

3-430