<strong>DVP</strong>-<strong>ES2</strong>/<strong>EX2</strong>/<strong>SS2</strong>/<strong>SA2</strong>/<strong>SX2</strong> <strong>Operation</strong> <strong>Manual</strong> - Programming<br />

= D0 K1 DPPMR D200 D202 K100000 Y0<br />

= D0 K2 DPPMR D204 D206 K100000 Y0<br />

= D0 K3 DPPMR D208 D210 K100000 Y0<br />

= D0 K4 DPPMR D212 D214 K100000 Y0<br />

M0<br />

RST<br />

M1029<br />

MOV<br />

K1<br />

D0<br />

M0<br />

M1029<br />

INCP<br />

D0<br />

END<br />

3. <strong>Operation</strong>:<br />

When PLC runs and M0 = ON, PLC will start the first point-to-point motion by 100KHz. D0 will<br />

plus 1 whenever a point-to-point motion is completed and the second point-to-point motion will<br />

start to execute automatically. The operation pattern repeats until the fourth point-to-point<br />

motion is completed.<br />

Points to note:<br />

Associated flags and registers:<br />

M1029: CH0 (Y0, Y1) pulse output execution completed<br />

D1030: Present number of Y0 output pulses (HIGH WORD).<br />

D1031: Present number of Y1 output pulses (LOW WORD).<br />

D1336: Present value of Y2 pulse output. D1336 (High word)<br />

D1337: Present value of Y2 pulse output. D1337(Low word)<br />

D1340:<br />

Start/end frequency of pulse output CH0 (Y0), CH1(Y2) for DPPMR/DPPMA<br />

instruction<br />

D1343:<br />

Ramp up/down time of pulse output CH0 (Y0), CH1(Y2) for DPPMR/DPPMA<br />

instruction<br />