3. Instruction Set<br />

API Mnemonic Operands Function<br />

169 D HOUR Hour meter<br />

Controllers<br />

<strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong> <strong>SA2</strong> <strong>SX2</strong><br />

SE<br />

Type<br />

Bit Devices Word devices Program Steps<br />

OP X Y M S K H KnX KnY KnM KnS T C D E F<br />

S * * * * * * * * * * *<br />

D 1 *<br />

D 2 * * *<br />

HOUR: 7 steps<br />

DHOUR: 13 steps<br />

PULSE 16-bit 32-bit<br />

<strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong> <strong>SA2</strong><br />

<strong>SA2</strong><br />

<strong>SA2</strong><br />

<strong>SX2</strong> <strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong> <strong>SX2</strong> <strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong><br />

SE SE SE <strong>SX2</strong><br />

Operands:<br />

S: Set-point value for driving the output device (Unit: hour) D 1 : Current time being measured<br />

D 2 : Output device<br />

Explanations:<br />

1. HOUR instruction drives the output device D 2 when the measured current time D 1 reaches the<br />

set-point value in S.<br />

2. Range of S: K1~K32,767; unit: hour. Range of D 1 in 16-bit instruction: K0~K32,767. Range of<br />

D 1 +1 (current time less than an hour): K0 ~K3,599; unit: second.<br />

3. When the ON-time of the drive contact reaches the set-point value, output device will be ON.<br />

The instruction can be applied for controlling the working hours of machine or conducting<br />

preventive maintenance.<br />

4. After output device is ON, the current time will still be measured in D 1 .<br />

5. In 16-bit instruction, when the current time measured reaches the maximum 32,767 hours /<br />

3,599 seconds, the timing will stop. To restart the timing, D 1 and D 1 + 1 have to be reset.<br />

6. In 32-bit instruction, when the current time measured reaches the maximum 2,147,483,647<br />

hours / 3,599 seconds, the timing will stop. To restart the timing, D 1 ~ D 1 + 2 have to be reset.<br />

7. If operand S uses device F, only 16-bit instruction is available.<br />

8. HOUR instruction can be used for four times in the program.<br />

Program Example 1:<br />

In 16-bit instruction, when X0 = ON, Y20 will be ON and the timing will start. When the timing<br />

reaches 100 hours, Y0 will be ON and D0 will record the current time measured (in hour). D1 will<br />

record the current time less than an hour (0 ~ 3,599; unit: second)..<br />

X0<br />

Y20<br />

Y20<br />

HOUR<br />

K100<br />

D0<br />

Y0<br />

3-387