• This instruction can be used many times in user program, but only one instruction will be<br />

activated at a time. For example, if Y0 is currently activated, other instructions use Y0<br />

won’t be executed. Therefore, instructions first activated will be first executed.<br />

• After activating the instruction, all parameters cannot be modified unless instruction is<br />

OFF.<br />

3. Associated Flags:<br />

M1029 CH0 (Y0, Y1) pulse output execution completed.<br />

M1102<br />

M1078<br />

M1104<br />

M1108<br />

M1110<br />

M1156<br />

M1158<br />

M1305<br />

M1306<br />

M1347<br />

M1524<br />

M1534<br />

CH1 (Y2, Y3) pulse output execution completed<br />

CH0 (Y0, Y1) pulse output pause (immediate)<br />

CH1 (Y2, Y3) pulse output pause (immediate)<br />

CH0 (Y0, Y1) pulse output pause (ramp down).<br />

CH1 (Y2, Y3) pulse output pause (ramp down)<br />

Enabling the mask and alignment mark function on I400/I401(X4) corresponding<br />

to Y0.<br />

Enabling the mask and alignment mark function on I600/I601(X6) corresponding<br />

to Y2.<br />

Reverse Y1 pulse output direction in high speed pulse output instructions<br />

Reverse Y3 pulse output direction in high speed pulse output instructions<br />

Auto-reset Y0 when high speed pulse output completed<br />

Auto-reset Y2 when high speed pulse output completed<br />

Enable ramp-down time setting on Y0. Has to be used with D1348<br />

M1535 Enable ramp-down time setting on Y2. Has to be used with D1349.<br />

M1538 Indicating pause status of CH0 (Y0, Y1)<br />

M1540 Indicating pause status of CH1 (Y2, Y3)<br />

4. Special D registers:<br />

D1030<br />

D1031<br />

D1336<br />

D1337<br />

Low word of the present value of Y0 pulse output<br />

High word of the present value of Y0 pulse output<br />

Low word of the present value of Y2 pulse output<br />

High word of the present value of Y2 pulse output<br />

D1340 Start/end frequency of the 1st group pulse output CH0 (Y0, Y1)<br />

D1352 Start/end frequency of the 2nd group pulse output CH1 (Y2, Y3)<br />

D1343 Ramp up/down time of the 1st group pulse output CH0 (Y0, Y1)<br />

D1353 Ramp up/down time of the 2nd group pulse output CH1 (Y2, Y3)<br />

D1348: CH0(Y0, Y1) pulse output. When M1534 = ON, D1348 stores the ramp-down time<br />

D1349: CH1(Y2, Y3) pulse output. When M1535 = ON, D1349 stores the ramp-down time<br />